Trace analysis of environmental matrices by large-volume injection and liquid chromatography–mass spectrometry

The time-honored convention of concentrating aqueous samples by solid-phase extraction (SPE) is being challenged by the increasingly widespread use of large-volume injection (LVI) liquid chromatography–mass spectrometry (LC–MS) for the determination of traces of polar organic contaminants in environmental samples. Although different LVI approaches have been proposed over the last 40 years, the simplest and most popular way of performing LVI is known as single-column LVI (SC-LVI), in which a large-volume of an aqueous sample is directly injected into an analytical column. For the purposes of this critical review, LVI is defined as an injected sample volume that is ≥10% of the void volume of the analytical column. Compared with other techniques, SC-LVI is easier to set up, because it requires only small hardware modifications to existing autosamplers and, thus, it will be the main focus of this review. Although not new, SC-LVI is gaining acceptance and the approach is emerging as a technique that will render SPE nearly obsolete for many environmental applications. In this review, we discuss: the history and development of various forms of LVI; the critical factors that must be considered when creating and optimizing SC-LVI methods; and typical applications that demonstrate the range of environmental matrices to which LVI is applicable, for example drinking water, groundwater, and surface water including seawater and wastewater. Furthermore, we indicate direction and areas that must be addressed to fully delineate the limits of SC-LVI.

[1]  R. A. Baumann,et al.  Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples. , 2000, Journal of chromatography. A.

[2]  J. Layne,et al.  Volume-load capacity in fast-gradient liquid chromatography effect of sample solvent composition and injection volume on chromatographic performance. , 2001, Journal of chromatography. A.

[3]  N. Jonkers,et al.  Occurrence and sources of selected phenolic endocrine disruptors in Ria de Aveiro, Portugal , 2009, Environmental science and pollution research international.

[4]  R. Dalterio,et al.  Analyte solvent and injection volume as variables affecting method development in semipreparative reversed-phase liquid chromatography. , 2007, Journal of separation science.

[5]  J. V. Sancho,et al.  Trace determination of triazine herbicides by means of coupled-column liquid chromatography and large volume injection , 1997 .

[6]  J. Field,et al.  In-Vial Derivatization and Empore Disk Elution for the Quantitative Determination of the Carboxylic Acid Metabolites of Dacthal in Groundwater , 1995 .

[7]  Will J. Backe,et al.  Analysis of androgenic steroids in environmental waters by large-volume injection liquid chromatography tandem mass spectrometry. , 2011, Analytical chemistry.

[8]  W. J. Lough,et al.  Assessment of injection volume limits when using on-column focusing with microbore liquid chromatography , 1997 .

[9]  Tsuyoshi Okazawa,et al.  Analysis of perfluorinated acids at parts-per-quadrillion levels in seawater using liquid chromatography-tandem mass spectrometry. , 2004, Environmental science & technology.

[10]  L. Alder,et al.  Fast multiresidue screening of 300 pesticides in water for human consumption by LC-MS/MS , 2008, Analytical and bioanalytical chemistry.

[11]  U. Brinkman,et al.  Coupled-column reversed-phase liquid chromatography—UV analyser for the determination of polar pesticides in water , 1993 .

[12]  Jennifer A Field,et al.  Quantitative determination of fluorotelomer sulfonates in groundwater by LC MS/MS. , 2004, Environmental science & technology.

[13]  Dietrich A. Volmer,et al.  Ion suppression: A major concern in mass spectrometry , 2006 .

[14]  W. Schulz,et al.  Novel applications of highly sensitive liquid chromatography/mass spectrometry/mass spectrometry for the direct detection of ultra-trace levels of contaminants in water. , 2006, Rapid communications in mass spectrometry : RCM.

[15]  C. Poole,et al.  Contributions of theory to method development in solid-phase extraction. , 2000, Journal of chromatography. A.

[16]  Christoph Mathieu,et al.  Analysis of llicit and illicit drugs in waste, surface and lake water samples using large volume direct injection high performance liquid chromatography--electrospray tandem mass spectrometry (HPLC-MS/MS). , 2010, Chemosphere.

[17]  U. Brinkman,et al.  Coupled column liquid chromatography for the trace determination of polar pesticides in water using direct large-volume injection : method development strategy applied to methyl isothiocyanate , 1992 .

[18]  L. Pérez-Arribas,et al.  Determination of chlorophenoxy acid herbicides and their esters in soil by capillary high performance liquid chromatography with ultraviolet detection, using large volume injection and temperature gradient , 2002 .

[19]  J. V. Sancho,et al.  Coupled-column liquid chromatography applied to the trace-level determination of triazine herbicides and some of their metabolites in water samples. , 1998, Analytical chemistry.

[20]  J. V. Sancho,et al.  Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection. , 2001, Journal of chromatography. A.

[21]  K. Linge,et al.  Occurrence of iodinated X-ray contrast media in indirect potable reuse systems , 2010, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[22]  J. Llorca-Pórcel,et al.  Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry. , 2008, Analytica Chimica Acta.

[23]  T. S. Thompson,et al.  Large volume injection for the direct analysis of ionophores and avermectins in surface water by liquid chromatography-electrospray ionization tandem mass spectrometry. , 2009, Analytica chimica acta.

[24]  L. Stolker,et al.  Potential of capillary-column-switching liquid chromatography-tandem mass spectrometry for the quantitative trace analysis of small molecules. Application to the on-line screening of drugs in water. , 2004, Journal of chromatography. A.

[25]  R. Buck,et al.  Matrix effect-free analytical methods for determination of perfluorinated carboxylic acids in environmental matrixes. , 2005, Analytical chemistry.

[26]  J. V. Sancho,et al.  Study of different atmospheric-pressure interfaces for LC-MS/MS determination of acrylamide in water at sub-ppb levels. , 2006, Journal of mass spectrometry : JMS.

[27]  J. V. Sancho,et al.  Direct determination of bromacil and diuron residues in environmental water samples by coupled-column liquid chromatography and large-volume injection , 1997 .

[28]  R. Vreeken,et al.  Determination of polar organophosphorus pesticides in aqueous samples by direct injection using liquid chromatography-tandem mass spectrometry. , 2001, Journal of chromatography. A.

[29]  Scott A Mabury,et al.  Trace level determination of perfluorinated compounds in water by direct injection. , 2008, Chemosphere.

[30]  P. de Voogt,et al.  Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry. , 2010, Journal of Chromatography A.

[31]  John W. Dolan,et al.  High-Performance Gradient Elution: The Practical Application of the Linear-Solvent-Strength Model , 2006 .

[32]  C. Chassaing,et al.  Direct analysis of crude plasma samples by turbulent flow chromatography/tandem mass spectrometry , 2000 .

[33]  R. A. Yokley,et al.  Direct aqueous injection liquid chromatography/electrospray ionization-mass spectrometry/mass spectrometry analysis of water for atrazine, simazine, and their chlorotriazine metabolites. , 2006, Journal of agricultural and food chemistry.

[34]  R. Góra,et al.  Method of fast trace microanalysis of the chiral pesticides epoxiconazole and novaluron in soil samples using off-line flow-through extraction and on-column direct large volume injection in reversed-phase high performance liquid chromatography. , 2007, Journal of separation science.

[35]  John W. Dolan,et al.  Introduction to modern liquid chromatography , 1974 .

[36]  M. S. Mills,et al.  Solid-Phase Extraction: Principles and Practice , 1998 .

[37]  W. Giger,et al.  Determination of Benzene- and Naphthalenesulfonates in Wastewater by Solid-Phase Extraction with Graphitized Carbon Black and Ion-Pair Liquid Chromatography with UV Detection , 1995 .

[38]  A. L. Roberts,et al.  Quantification of drugs of abuse in municipal wastewater via SPE and direct injection liquid chromatography mass spectrometry , 2010, Analytical and bioanalytical chemistry.

[39]  A. Cappiello,et al.  Large volume injection of acidic pesticides by reversed-phase micro high-performance liquid chromatography , 1997 .

[40]  J. N. Little,et al.  New considerations in detector-application relationships. , 1975, Journal of chromatography.

[41]  P. Zoonen,et al.  Reversed-phase liquid chromatographic column switching for the trace-level determination of polar compounds : Application to chloroallyl alcohol in ground water , 1990 .

[42]  K. Olsen,et al.  Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm I.D. , 1997, Journal of chromatography. A.

[43]  Christoph Ort,et al.  Occurrence and mass flows of fluorochemicals in the Glatt Valley watershed, Switzerland. , 2008, Environmental science & technology.

[44]  T. Reemtsma,et al.  Rapid and sensitive determination of ethylenediaminetetraacetic acid and diethylenetriaminepentaacetic acid in water samples by ion-pair reversed-phase liquid chromatography--electrospray tandem mass spectrometry. , 2007, Journal of chromatography. A.

[45]  Nobuyoshi Yamashita,et al.  A global survey of perfluorinated acids in oceans. , 2005, Marine pollution bulletin.

[46]  J. Field,et al.  Determination of alkylbenzene metabolites in groundwater by solid-phase extraction and liquid chromatography-tandem mass spectrometry. , 2004, Journal of chromatography. A.

[47]  J. Hlavay,et al.  The role of capacity factor in method development for solid-phase extraction of phenolic compounds. II , 1995 .

[48]  T. Schmidt,et al.  Determination of the polar pesticide degradation product N,N-dimethylsulfamide in aqueous matrices by UPLC–MS/MS , 2009, Analytical and bioanalytical chemistry.

[49]  C. Banta-Green,et al.  Eliminating solid phase extraction with large-volume injection LC/MS/MS: analysis of illicit and legal drugs and human urine indicators in U.S. wastewaters. , 2008, Environmental science & technology.

[50]  B. Patterson,et al.  Fate of nine recycled water trace organic contaminants and metal(loid)s during managed aquifer recharge into a anaerobic aquifer: Column studies. , 2010, Water research.

[51]  Francesco Busetti,et al.  Rapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry. , 2008, Journal of chromatography. A.

[52]  R. Gloor,et al.  Practical Aspects off Reverse Phase Ion Pair Chromatography , 1977 .

[53]  J. Hlavay,et al.  A simple method for the determination of capacity factor on solid-phase extraction cartridges. I , 1995 .

[54]  Stuart Williams,et al.  Ghost peaks in reversed-phase gradient HPLC: a review and update. , 2004, Journal of chromatography. A.

[55]  G. Saccani,et al.  Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry. , 2004, Journal of chromatography. A.

[56]  A. Cappiello,et al.  Enhanced detection sensitivity by large volume injection in reversed-phase micro-high-performance liquid chromatography , 1996 .

[57]  Jennifer A Field,et al.  Quantitative determination of fluorinated alkyl substances by large-volume-injection liquid chromatography tandem mass spectrometry-characterization of municipal wastewaters. , 2006, Environmental science & technology.

[58]  M. Hutta,et al.  Method of analysis of a selected group of pyrethroids in soil samples using off-line flow-through extraction and on-column direct large-volume injection in reversed phase high performance liquid chromatography. , 2006, Journal of separation science.

[59]  F. Busetti,et al.  Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant. , 2006, Journal of chromatography. A.

[60]  A. D. de Jong,et al.  Screening and analysis of polar pesticides in environmental monitoring programmes by coupled-column liquid chromatography and gas chromatography-mass spectrometry. , 1996, Journal of chromatography. A.

[61]  T. Reemtsma,et al.  Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry. , 2005, Analytical chemistry.

[62]  W. Niessen,et al.  Determination of pesticides in vegetables using large-volume injection column liquid chromatography-electrospray tandem mass spectrometry. , 2000, Journal of chromatography. A.

[63]  Y. Kiso,et al.  Pesticide analysis by high-performance liquid chromatography using the direct injection method , 1996 .

[64]  L. Pérez-Arribas,et al.  Large injection volumes in capillary liquid chromatography: Study of the effect of focusing on chromatographic performance. , 2010, Journal of chromatography. A.