Trace analysis of environmental matrices by large-volume injection and liquid chromatography–mass spectrometry
暂无分享,去创建一个
Jennifer A Field | Francesco Busetti | Walter Giger | Will J. Backe | F. Busetti | W. Giger | J. Field | B. Place | Will J Backe | Nina Bendixen | Urs Maier | Benjamin Place | Nina Bendixen | U. Maier
[1] R. A. Baumann,et al. Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples. , 2000, Journal of chromatography. A.
[2] J. Layne,et al. Volume-load capacity in fast-gradient liquid chromatography effect of sample solvent composition and injection volume on chromatographic performance. , 2001, Journal of chromatography. A.
[3] N. Jonkers,et al. Occurrence and sources of selected phenolic endocrine disruptors in Ria de Aveiro, Portugal , 2009, Environmental science and pollution research international.
[4] R. Dalterio,et al. Analyte solvent and injection volume as variables affecting method development in semipreparative reversed-phase liquid chromatography. , 2007, Journal of separation science.
[5] J. V. Sancho,et al. Trace determination of triazine herbicides by means of coupled-column liquid chromatography and large volume injection , 1997 .
[6] J. Field,et al. In-Vial Derivatization and Empore Disk Elution for the Quantitative Determination of the Carboxylic Acid Metabolites of Dacthal in Groundwater , 1995 .
[7] Will J. Backe,et al. Analysis of androgenic steroids in environmental waters by large-volume injection liquid chromatography tandem mass spectrometry. , 2011, Analytical chemistry.
[8] W. J. Lough,et al. Assessment of injection volume limits when using on-column focusing with microbore liquid chromatography , 1997 .
[9] Tsuyoshi Okazawa,et al. Analysis of perfluorinated acids at parts-per-quadrillion levels in seawater using liquid chromatography-tandem mass spectrometry. , 2004, Environmental science & technology.
[10] L. Alder,et al. Fast multiresidue screening of 300 pesticides in water for human consumption by LC-MS/MS , 2008, Analytical and bioanalytical chemistry.
[11] U. Brinkman,et al. Coupled-column reversed-phase liquid chromatography—UV analyser for the determination of polar pesticides in water , 1993 .
[12] Jennifer A Field,et al. Quantitative determination of fluorotelomer sulfonates in groundwater by LC MS/MS. , 2004, Environmental science & technology.
[13] Dietrich A. Volmer,et al. Ion suppression: A major concern in mass spectrometry , 2006 .
[14] W. Schulz,et al. Novel applications of highly sensitive liquid chromatography/mass spectrometry/mass spectrometry for the direct detection of ultra-trace levels of contaminants in water. , 2006, Rapid communications in mass spectrometry : RCM.
[15] C. Poole,et al. Contributions of theory to method development in solid-phase extraction. , 2000, Journal of chromatography. A.
[16] Christoph Mathieu,et al. Analysis of llicit and illicit drugs in waste, surface and lake water samples using large volume direct injection high performance liquid chromatography--electrospray tandem mass spectrometry (HPLC-MS/MS). , 2010, Chemosphere.
[17] U. Brinkman,et al. Coupled column liquid chromatography for the trace determination of polar pesticides in water using direct large-volume injection : method development strategy applied to methyl isothiocyanate , 1992 .
[18] L. Pérez-Arribas,et al. Determination of chlorophenoxy acid herbicides and their esters in soil by capillary high performance liquid chromatography with ultraviolet detection, using large volume injection and temperature gradient , 2002 .
[19] J. V. Sancho,et al. Coupled-column liquid chromatography applied to the trace-level determination of triazine herbicides and some of their metabolites in water samples. , 1998, Analytical chemistry.
[20] J. V. Sancho,et al. Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection. , 2001, Journal of chromatography. A.
[21] K. Linge,et al. Occurrence of iodinated X-ray contrast media in indirect potable reuse systems , 2010, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.
[22] J. Llorca-Pórcel,et al. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry. , 2008, Analytica Chimica Acta.
[23] T. S. Thompson,et al. Large volume injection for the direct analysis of ionophores and avermectins in surface water by liquid chromatography-electrospray ionization tandem mass spectrometry. , 2009, Analytica chimica acta.
[24] L. Stolker,et al. Potential of capillary-column-switching liquid chromatography-tandem mass spectrometry for the quantitative trace analysis of small molecules. Application to the on-line screening of drugs in water. , 2004, Journal of chromatography. A.
[25] R. Buck,et al. Matrix effect-free analytical methods for determination of perfluorinated carboxylic acids in environmental matrixes. , 2005, Analytical chemistry.
[26] J. V. Sancho,et al. Study of different atmospheric-pressure interfaces for LC-MS/MS determination of acrylamide in water at sub-ppb levels. , 2006, Journal of mass spectrometry : JMS.
[27] J. V. Sancho,et al. Direct determination of bromacil and diuron residues in environmental water samples by coupled-column liquid chromatography and large-volume injection , 1997 .
[28] R. Vreeken,et al. Determination of polar organophosphorus pesticides in aqueous samples by direct injection using liquid chromatography-tandem mass spectrometry. , 2001, Journal of chromatography. A.
[29] Scott A Mabury,et al. Trace level determination of perfluorinated compounds in water by direct injection. , 2008, Chemosphere.
[30] P. de Voogt,et al. Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry. , 2010, Journal of Chromatography A.
[31] John W. Dolan,et al. High-Performance Gradient Elution: The Practical Application of the Linear-Solvent-Strength Model , 2006 .
[32] C. Chassaing,et al. Direct analysis of crude plasma samples by turbulent flow chromatography/tandem mass spectrometry , 2000 .
[33] R. A. Yokley,et al. Direct aqueous injection liquid chromatography/electrospray ionization-mass spectrometry/mass spectrometry analysis of water for atrazine, simazine, and their chlorotriazine metabolites. , 2006, Journal of agricultural and food chemistry.
[34] R. Góra,et al. Method of fast trace microanalysis of the chiral pesticides epoxiconazole and novaluron in soil samples using off-line flow-through extraction and on-column direct large volume injection in reversed-phase high performance liquid chromatography. , 2007, Journal of separation science.
[35] John W. Dolan,et al. Introduction to modern liquid chromatography , 1974 .
[36] M. S. Mills,et al. Solid-Phase Extraction: Principles and Practice , 1998 .
[37] W. Giger,et al. Determination of Benzene- and Naphthalenesulfonates in Wastewater by Solid-Phase Extraction with Graphitized Carbon Black and Ion-Pair Liquid Chromatography with UV Detection , 1995 .
[38] A. L. Roberts,et al. Quantification of drugs of abuse in municipal wastewater via SPE and direct injection liquid chromatography mass spectrometry , 2010, Analytical and bioanalytical chemistry.
[39] A. Cappiello,et al. Large volume injection of acidic pesticides by reversed-phase micro high-performance liquid chromatography , 1997 .
[40] J. N. Little,et al. New considerations in detector-application relationships. , 1975, Journal of chromatography.
[41] P. Zoonen,et al. Reversed-phase liquid chromatographic column switching for the trace-level determination of polar compounds : Application to chloroallyl alcohol in ground water , 1990 .
[42] K. Olsen,et al. Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm I.D. , 1997, Journal of chromatography. A.
[43] Christoph Ort,et al. Occurrence and mass flows of fluorochemicals in the Glatt Valley watershed, Switzerland. , 2008, Environmental science & technology.
[44] T. Reemtsma,et al. Rapid and sensitive determination of ethylenediaminetetraacetic acid and diethylenetriaminepentaacetic acid in water samples by ion-pair reversed-phase liquid chromatography--electrospray tandem mass spectrometry. , 2007, Journal of chromatography. A.
[45] Nobuyoshi Yamashita,et al. A global survey of perfluorinated acids in oceans. , 2005, Marine pollution bulletin.
[46] J. Field,et al. Determination of alkylbenzene metabolites in groundwater by solid-phase extraction and liquid chromatography-tandem mass spectrometry. , 2004, Journal of chromatography. A.
[47] J. Hlavay,et al. The role of capacity factor in method development for solid-phase extraction of phenolic compounds. II , 1995 .
[48] T. Schmidt,et al. Determination of the polar pesticide degradation product N,N-dimethylsulfamide in aqueous matrices by UPLC–MS/MS , 2009, Analytical and bioanalytical chemistry.
[49] C. Banta-Green,et al. Eliminating solid phase extraction with large-volume injection LC/MS/MS: analysis of illicit and legal drugs and human urine indicators in U.S. wastewaters. , 2008, Environmental science & technology.
[50] B. Patterson,et al. Fate of nine recycled water trace organic contaminants and metal(loid)s during managed aquifer recharge into a anaerobic aquifer: Column studies. , 2010, Water research.
[51] Francesco Busetti,et al. Rapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry. , 2008, Journal of chromatography. A.
[52] R. Gloor,et al. Practical Aspects off Reverse Phase Ion Pair Chromatography , 1977 .
[53] J. Hlavay,et al. A simple method for the determination of capacity factor on solid-phase extraction cartridges. I , 1995 .
[54] Stuart Williams,et al. Ghost peaks in reversed-phase gradient HPLC: a review and update. , 2004, Journal of chromatography. A.
[55] G. Saccani,et al. Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry. , 2004, Journal of chromatography. A.
[56] A. Cappiello,et al. Enhanced detection sensitivity by large volume injection in reversed-phase micro-high-performance liquid chromatography , 1996 .
[57] Jennifer A Field,et al. Quantitative determination of fluorinated alkyl substances by large-volume-injection liquid chromatography tandem mass spectrometry-characterization of municipal wastewaters. , 2006, Environmental science & technology.
[58] M. Hutta,et al. Method of analysis of a selected group of pyrethroids in soil samples using off-line flow-through extraction and on-column direct large-volume injection in reversed phase high performance liquid chromatography. , 2006, Journal of separation science.
[59] F. Busetti,et al. Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant. , 2006, Journal of chromatography. A.
[60] A. D. de Jong,et al. Screening and analysis of polar pesticides in environmental monitoring programmes by coupled-column liquid chromatography and gas chromatography-mass spectrometry. , 1996, Journal of chromatography. A.
[61] T. Reemtsma,et al. Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry. , 2005, Analytical chemistry.
[62] W. Niessen,et al. Determination of pesticides in vegetables using large-volume injection column liquid chromatography-electrospray tandem mass spectrometry. , 2000, Journal of chromatography. A.
[63] Y. Kiso,et al. Pesticide analysis by high-performance liquid chromatography using the direct injection method , 1996 .
[64] L. Pérez-Arribas,et al. Large injection volumes in capillary liquid chromatography: Study of the effect of focusing on chromatographic performance. , 2010, Journal of chromatography. A.