FEM-based evaluation of deformable image registration for radiation therapy

This paper presents a new concept to automatically detect the neighborhood in an image where deformable registration is mis-performing. Specifically, the displacement vector field (DVF) from a deformable image registration is substituted into a finite-element-based elastic framework to calculate unbalanced energy in each element. The value of the derived energy indicates the quality of the DVF in its neighborhood. The new voxel-based evaluation approach is compared with three other validation criteria: landmark measurement, a finite element approach and visual comparison, for deformable registrations performed with the optical-flow-based 'demons' algorithm as well as thin-plate spline interpolation. This analysis was performed on three pairs of prostate CT images. The results of the analysis show that the four criteria give mutually comparable quantitative assessments on the six registration instances. As an objective concept, the unbalanced energy presents no requirement on boundary constraints in its calculation, different from traditional mechanical modeling. This method is automatic, and at voxel level suitable to evaluate deformable registration in a clinical setting.

[1]  D. Yan,et al.  Reducing uncertainties in volumetric image based deformable organ registration. , 2003, Medical physics.

[2]  Carl-Fredrik Westin,et al.  Capturing intraoperative deformations: research experience at Brigham and Women's hospital , 2005, Medical Image Anal..

[3]  Jun Duan,et al.  Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study. , 2006, Medical physics.

[4]  James C. Gee,et al.  Validation of a non-rigid registration algorithm for multi-modal data , 2002 .

[5]  Y Chi,et al.  A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models. , 2006, Medical physics.

[6]  R. Rabbitt,et al.  3D brain mapping using a deformable neuroanatomy. , 1994, Physics in medicine and biology.

[7]  O. C. Zienkiewicz,et al.  The Finite Element Method: Basic Formulation and Linear Problems , 1987 .

[8]  J. Greenleaf,et al.  Selected methods for imaging elastic properties of biological tissues. , 2003, Annual review of biomedical engineering.

[9]  G S Bauman,et al.  Tracking the dose distribution in radiation therapy by accounting for variable anatomy , 2004, Physics in medicine and biology.

[10]  Joe Y. Chang,et al.  Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy , 2005, Physics in medicine and biology.

[11]  Ken Goldberg,et al.  Image Registration for Prostate MR Spectroscopy Using Biomechanical Modeling and Optimization of Force and Stiffness Parameters , 2004, EMBC 2004.

[12]  Kawal S. Rhode,et al.  Tissue deformation and shape models in image-guided interventions: a discussion paper , 2005, Medical Image Anal..

[13]  David J. Hawkes,et al.  Validation of nonrigid image registration using finite-element methods: application to breast MR images , 2003, IEEE Transactions on Medical Imaging.

[14]  Ron Kikinis,et al.  Serial registration of intraoperative MR images of the brain , 2002, Medical Image Anal..

[15]  Christos Davatzikos,et al.  Spatial Transformation and Registration of Brain Images Using Elastically Deformable Models , 1997, Comput. Vis. Image Underst..

[16]  Terry M. Peters,et al.  Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries , 2004, Medical Image Anal..

[17]  Hualiang Zhong,et al.  A real time finite element based tissue simulation method incorporating nonlinear elastic behavior , 2005, Computer methods in biomechanics and biomedical engineering.

[18]  D. Louis Collins,et al.  Twenty New Digital Brain Phantoms for Creation of Validation Image Data Bases , 2006, IEEE Transactions on Medical Imaging.

[19]  Ron Kikinis,et al.  3D Image Matching Using a Finite Element Based Elastic Deformation Model , 1999, MICCAI.

[20]  A. Sarvazyan,et al.  Development of mechanical models of breast and prostate with palpable nodules , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[21]  Radhe Mohan,et al.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. , 2005, Medical physics.

[22]  Morten Bro-Nielsen,et al.  Fast Fluid Registration of Medical Images , 1996, VBC.

[23]  Ron Kikinis,et al.  Registration of 3D Intraoperative MR Images of the Brain Using a Finite Element Biomechanical Model , 2001, IEEE Trans. Medical Imaging.

[24]  Jean-Philippe Thirion,et al.  Image matching as a diffusion process: an analogy with Maxwell's demons , 1998, Medical Image Anal..

[25]  I-Chow Hsu,et al.  Image registration for prostate MR spectroscopy using modeling and optimization of force and stiffness parameters , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[26]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[27]  Sarang Joshi,et al.  Large deformation three-dimensional image registration in image-guided radiation therapy , 2005, Physics in medicine and biology.

[28]  James C. Gee,et al.  Validation of a nonrigid registration algorithm for multimodal data , 2002, SPIE Medical Imaging.

[29]  A. Boyer,et al.  Inverse planning for functional image-guided intensity-modulated radiation therapy. , 2002, Physics in medicine and biology.

[30]  A. Riegel,et al.  Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion. , 2005, International journal of radiation oncology, biology, physics.

[31]  Karl Rohr,et al.  Parameter-Free Elastic Deformation Approach for 2D and 3D Registration Using Prescribed Displacements , 1999, Journal of Mathematical Imaging and Vision.

[32]  S Webb,et al.  Does elastic tissue intrafraction motion with density changes forbid motion-compensated radiotherapy? , 2006, Physics in medicine and biology.

[33]  Jeffrey V Siebers,et al.  Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans. , 2005, International journal of radiation oncology, biology, physics.