A comparison of techniques for automatic detection of stiction: simulation and application to industrial data

This paper illustrates the effect of stiction in actuators on closed loop performance and the importance of techniques, to be incorporated in the monitoring system, for automatic detection of the onset of this phenomenon. Three different techniques are compared on the basis of simulation by means of stiction models and it is shown how loop variables are affected by stiction parameters and by process characteristics. A major finding is that every technique has an uncertainty region where no decision can be taken in the absence of further information about the process. The application on industrial data, recorded on loops affected by stiction during routine plant operation, allows to confirm this result and to assess relative efficiency of the techniques. A simple test to be performed directly on the plant is also proposed to solve the remaining uncertain cases.

[1]  Alf Isaksson,et al.  A Method for Detection of Stiction in Control Valves , 1998 .

[2]  Nina F. Thornhill,et al.  Refinery-wide control loop performance assessment , 1999 .

[3]  Nina F. Thornhill,et al.  Diagnosis of poor control-loop performance using higher-order statistics , 2004, Autom..

[4]  Fredrik Gustafsson,et al.  A segmentation‐based method for detection of stiction in control valves , 2003 .

[5]  Cheng-Ching Yu,et al.  Improved Autotuning Using the Shape Factor from Relay Feedback , 2003 .

[6]  Carlos Canudas de Wit,et al.  A survey of models, analysis tools and compensation methods for the control of machines with friction , 1994, Autom..

[7]  A qualitative shape analysis formalism for monitoring control loop performance , 2001 .

[8]  William L. Luyben Getting more information from relay-feedback tests , 2001 .

[9]  Manabu Kano,et al.  Practical Model and Detection Algorithm for Valve Stiction , 2004 .

[10]  Claudio Scali,et al.  Automatic Detection of Stiction in Actuators: A Technique to Reduce the Number of Uncertain Cases , 2004 .

[11]  Alexander Horch A simple method for detection of stiction in control valves , 1999 .

[12]  Alf J. Isaksson,et al.  Detection of valve stiction in integrating processes , 2001, 2001 European Control Conference (ECC).

[13]  Tore Hägglund,et al.  A Control-Loop Performance Monitor , 1995 .

[14]  Francis J. Doyle,et al.  Friction compensation for a process control valve , 2000 .

[15]  Tore Hägglund,et al.  Detection and Diagnosis of Oscillation in Control Loops , 1997 .

[16]  Cheng-Ching Yu Autotuning of PID Controllers , 1999 .

[17]  David Clarke Sensor, actuator, and loop validation , 1995 .

[18]  Shoukat M. A. A. Choudhury,et al.  Data-Driven Model of Valve Stiction , 2003 .

[19]  Dean Karnopp,et al.  Computer simulation of stick-slip friction in mechanical dynamic systems , 1985 .

[20]  S. Joe Qin,et al.  Control performance monitoring — a review and assessment , 1998 .

[21]  T. Hägglund A friction compensator for pneumatic control valves , 2002 .