Automatic local state detection for synchronous distributed generators

In order to avoid unnecessary loss of supply especially for high priority loads, distributed generators (DGs) stand-alone operation is getting more attention. However, to ensure more reliability, the islanded distribution network must reconnect to the grid as soon as the quality of supply from grid is refined. As the circuit breaker (CB) which had been opened for unintentional/intentional islanding operation is often kilometers far from the DG, introducing a reliable method for localized reconnection detection and proper DG control mode activation will be an interesting issue. Such a method could be implemented via a micro-processor based relay as a low cost alternate for the expensive communication means required between all of the CBs that may initiate the islanding and the DG. In this paper a suitable procedure to provide reconnection detection signal for synchronous type DGs is presented. The procedure is based on governor signal processing.

[1]  Peter W. Lehn,et al.  Microgrid autonomous operation during and subsequent to islanding process , 2004 .

[2]  Mohsen Karimi,et al.  Intelligent islanding detection of a synchronous distributed generation using governor signal cluste , 2011 .

[3]  Math Bollen,et al.  Controlled island operation of part of the 50-kV grid in Southern Sweden , 2009, 2009 IEEE Bucharest PowerTech.

[4]  G. Joós,et al.  A Fuzzy Rule-Based Approach for Islanding Detection in Distributed Generation , 2010, IEEE Transactions on Power Delivery.

[5]  P.W. Lehn,et al.  Micro-grid autonomous operation during and subsequent to islanding process , 2005, IEEE Transactions on Power Delivery.

[6]  R.J. Best,et al.  Synchronous Islanded Operation of a Diesel Generator , 2007, IEEE Transactions on Power Systems.

[7]  S.M. Kay,et al.  Spectrum analysis—A modern perspective , 1981, Proceedings of the IEEE.

[8]  M.H.J. Bollen,et al.  Categorization and analysis of power system transients , 2005, IEEE Transactions on Power Delivery.

[9]  Ehab F. El-Saadany,et al.  Islanding detection of grid connected distributed generators using TLS-ESPRIT , 2007 .

[10]  Birgitte Bak-Jensen,et al.  Control and operation of distributed generation in distribution systems , 2011 .

[11]  A Baum,et al.  Risks From Utility Supply Disruption , 2011, IEEE Industry Applications Magazine.

[12]  Dimitris G. Manolakis,et al.  Statistical and Adaptive Signal Processing , 2000 .

[13]  S. P. Chowdhury,et al.  Islanding protection of active distribution networks with renewable distributed generators: A comprehensive survey , 2009 .

[14]  Emilio Figueres,et al.  Review of anti-islanding techniques in distributed generators , 2010 .

[15]  D. John Morrow,et al.  Techniques for Multiple-Set Synchronous Islanding Control , 2011, IEEE Transactions on Smart Grid.

[16]  Walmir Freitas,et al.  Control systems analysis of industrial plants with synchronous generators during islanded operation , 2010, IEEE PES General Meeting.

[17]  Irene Yu-Hua Gu,et al.  Signal processing of power quality disturbances , 2006 .