Validity of pulse oximetry during exercise in elite endurance athletes.

Eleven highly trained male cyclists [maximal aerobic power (VO2max) = 70.6 +/- 4.2 ml.kg-1.min-1] performed both high intensity constant load (90-95% VO2max) and incremental cycle exercise tests with arterial blood sampling to evaluate the accuracy of pulse oximeter estimates (%SpO2) of arterial oxyhemoglobin fraction of total hemoglobin (%HbO2). Three subjects also performed an incremental exercise test in hypoxic conditions (inspired partial pressure of O2 = 89, 93, or 100 Torr). Arterial %HbO2 was determined via CO-oximetry and ranged from 72 to 99%. Three Ohmeda 3740 pulse oximeters were used to estimate %HbO2, one on each ear lobe and a finger probe. The finger probe tended to provide the best estimate of %HbO2 during exercise: the mean %SpO2 - %HbO2 difference for 232 exercise observations was 0.52 +/- 1.36% (SD). Finger probe %SpO2 and %HbO2 were highly correlated [r = 0.98, standard error of the estimate (SEE) = 1.32%, P less than 0.0001]. The accuracy of pulse oximeters has been questioned during high-intensity exercise. When aerobic power was greater than 81% of VO2max (n = 75), the finger probe's mean error was -0.01 +/- 1.40%. Finger probe %SpO2 and %HbO2 were highly correlated (r = 0.97, SEE = 1.32%, P less than 0.0001). These results indicate that this pulse oximeter is a valid predictor of %HbO2 in elite athletes during cycle exercise.

[1]  J. Dempsey,et al.  Effects of incomplete pulmonary gas exchange on VO2 max. , 1989, Journal of applied physiology.

[2]  S. Powers,et al.  Hemoglobin desaturation in highly trained athletes during heavy exercise. , 1986, Medicine and science in sports and exercise.

[3]  J. E. Hansen,et al.  Validity of ear oximetry in clinical exercise testing. , 1987, Chest.

[4]  A. Ries,et al.  Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. , 2015, The American review of respiratory disease.

[5]  Arthur S Slutsky,et al.  Ear oximetry during combined hypoxia and exercise. , 1986, Journal of applied physiology.

[6]  J. Gross,et al.  Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient response characteristics. , 1987, Anesthesiology.

[7]  S. Powers,et al.  Linear relationship between VO2max and VO2max decrement during exposure to acute hypoxia. , 1988, Journal of applied physiology.

[8]  J. Morris,et al.  Spirometric standards for healthy nonsmoking adults. , 2015, The American review of respiratory disease.