Fault ride-through performance evaluation of an interleaved grid-connected converter employing low switching frequency

This paper presents the performance evaluation under grid voltage sags of a two parallel-interleaved grid-connected converters employing low switching frequency. A current controller based on the synchronous reference frame including voltage feed-forward is used. The dominant frequency components from the direct- and quadrature-axis voltage Vd and Vq are eliminated by using an adaptive moving average filter. The dynamic performance of the converter during voltage sags is improved using an adaptive approach which minimizes the filter delay during the faults. The presented results conclude the performance of the converter system.

[1]  Ghanshyamsinh Vijaysinh Line filter design of parallel interleaved VSCs for high power wind energy conversion systems , 2016 .

[2]  S. Munk‐Nielsen,et al.  Analysis and modelling of circulating current in two parallel-connected inverters , 2015 .

[3]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[4]  M. Liserre,et al.  Power electronics converters for wind turbine systems , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[5]  Remus Teodorescu,et al.  Comparison between grid side and inverter side current control for parallel interleaved grid connected converters , 2015, 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe).

[6]  F. Blaabjerg,et al.  Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[7]  Jian Sun,et al.  A Comprehensive Study of Harmonic Cancellation Effects in Interleaved Three-Phase VSCs , 2007, 2007 IEEE Power Electronics Specialists Conference.

[8]  Josep M. Guerrero,et al.  Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines , 2014, IEEE Transactions on Power Electronics.

[9]  G. Narayanan,et al.  Minimization of Grid Current Distortion in Parallel-Connected Converters Through Carrier Interleaving , 2014, IEEE Transactions on Industrial Electronics.

[10]  Frede Blaabjerg,et al.  Integrated inductor for interleaved operation of two parallel three-phase voltage source converters , 2015, 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe).

[11]  Vassilios G. Agelidis,et al.  Current-Balancing Technique for Interleaved Voltage Source Inverters With Magnetically Coupled Legs Connected in Parallel , 2015, IEEE Transactions on Industrial Electronics.

[12]  F. Forest,et al.  Design and Comparison of Inductors and Intercell Transformers for Filtering of PWM Inverter Output , 2009, IEEE Transactions on Power Electronics.

[13]  Frede Blaabjerg,et al.  Design of the trap filter for the high power converters with parallel interleaved VSCs , 2014, IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society.

[14]  Frede Blaabjerg,et al.  An Integrated Inductor for Parallel Interleaved VSCs and PWM Schemes for Flux Minimization , 2015, IEEE Transactions on Industrial Electronics.

[15]  B. Andresen,et al.  A high power density converter system for the Gamesa G10x 4,5 MW wind turbine , 2007, 2007 European Conference on Power Electronics and Applications.

[16]  Frede Blaabjerg,et al.  An Integrated Inductor for Parallel Interleaved Three-Phase Voltage Source Converters , 2016, IEEE Transactions on Power Electronics.

[17]  M. Liserre,et al.  Evaluation of Current Controllers for Distributed Power Generation Systems , 2009, IEEE Transactions on Power Electronics.