Microminiaturized immunoassays using quantum dots as fluorescent label by laser confocal scanning fluorescence detection.

An immunoassay readout method based on fluorescent imaging analysis with laser confocal scanning is described. The ZnS-coated CdSe quantum dots (ZnS/CdSe QDs) were linked to a detection antibody. Immunoassay was carried out on a glass chip using a sandwich assay approach, where antibody covalently bound to a glass chip was allowed to capture antigen specially. Afterwards, the detection antibody labeled with QD was allowed to bind selectively to the captured antigen. The fluorescent signals of the sandwich conjugate were detected by a laser confocal scanner. A diode laser was used to excite efficiently the fluorescent signals while bovine serum albumin was used to eliminate nonspecific binding sites. The detection limit of this approach was up to 10(-9) M under current experimental conditions. The specificity of the QDs-labeled immunoglobulin (IgG) was tested by an experiment using goat IgG and human IgG samples. The result was consistent with the binding specificity in a sandwich-type assay. The potential of this method to function as a simple and efficient readout strategy for immunoassay in biochip is discussed.

[1]  S. Nie,et al.  Probing specific sequences on single DNA molecules with bioconjugated fluorescent nanoparticles. , 2000, Analytical chemistry.

[2]  S. Nie,et al.  Quantum dot bioconjugates for ultrasensitive nonisotopic detection. , 1998, Science.

[3]  I. Weeks,et al.  Chemiluminescence immunoassay: an overview. , 1986, Clinical science.

[4]  D. Balding,et al.  HLA Sequence Polymorphism and the Origin of Humans , 2006 .

[5]  I Hemmilä,et al.  Fluoroimmunoassays and immunofluorometric assays. , 1985, Clinical chemistry.

[6]  J. Vaitukaitis Radioimmunoassay of human choriogonadotropin. , 1985, Clinical chemistry.

[7]  Xiaogang Peng,et al.  Kinetics of II-VI and III-V Colloidal Semiconductor Nanocrystal Growth: “Focusing” of Size Distributions , 1998 .

[8]  I Karube,et al.  A novel method of immobilizing antibodies on a quartz crystal microbalance using plasma-polymerized films for immunosensors. , 1996, Analytical chemistry.

[9]  M. Bawendi,et al.  Synthesis and characterization of nearly monodisperse CdE (E = sulfur, selenium, tellurium) semiconductor nanocrystallites , 1993 .

[10]  G. Walker,et al.  Hybridization of fluorescein-labeled DNA oligomers detected by fluorescence anisotropy with protein binding enhancement. , 1995, Analytical chemistry.

[11]  R. Reich,et al.  Direct detection of nucleic acid hybridization on the surface of a charge coupled device. , 1994, Nucleic acids research.

[12]  P. Guyot-Sionnest,et al.  Synthesis and Characterization of Strongly Luminescing ZnS-Capped CdSe Nanocrystals , 1996 .