High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging.

PURPOSE To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr, Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. METHODS AND MATERIALS The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (Nmax) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, Nmax measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and Nmax (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ("outlier detection") for corrective actions than the DDHC and the BVI ("sliding average"). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. RESULTS The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the AvL and 0% in the DDHC and BVI), in agreement with the results of the simulation. The number of corrections (about 0.7 on the average per patient) was not larger than predicted. CONCLUSION The verification procedure appeared to be feasible in the three institutions and enabled a significant reduction of mean 3D setup deviations. The computer simulation of the procedure proved to be a useful tool, because it enabled an accurate prediction of the setup accuracy and the required number of corrections.

[1]  S. Griffiths,et al.  Quality control of radiotherapy during pelvic irradiation. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[3]  M van Herk,et al.  Automatic on-line inspection of patient setup in radiation therapy using digital portal images. , 1993, Medical physics.

[4]  R E Vijlbrief,et al.  Transfer errors of planning CT to simulator: a possible source of setup inaccuracies? , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  M van Herk,et al.  Optimization of automatic portal image analysis. , 1995, Medical physics.

[6]  A Dutreix,et al.  Is it necessary to repeat quality control procedures for head and neck patients? , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  D Yan,et al.  A new model for "accept or reject" strategies in off-line and on-line megavoltage treatment evaluation. , 1995, International journal of radiation oncology, biology, physics.

[8]  A G Visser,et al.  Accuracy in radiation field alignment in head and neck cancer: a prospective study. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  J W Denham,et al.  Objective decision-making following a portal film: the results of a pilot study. , 1993, International journal of radiation oncology, biology, physics.

[10]  J Bijhold,et al.  Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  M van Herk,et al.  A comprehensive system for the analysis of portal images. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  A Bel,et al.  Time trend of patient setup deviations during pelvic irradiation using electronic portal imaging. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  A Fenster,et al.  A digital fluoroscopic imaging device for radiotherapy localization. , 1990, International journal of radiation oncology, biology, physics.

[14]  M Coghe,et al.  Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  M van Herk,et al.  A verification procedure to improve patient set-up accuracy using portal images. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  J. Lebesque,et al.  The simultaneous boost technique: the concept of relative normalized total dose. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  A Fenster,et al.  Daily monitoring and correction of radiation field placement using a video-based portal imaging system: a pilot study. , 1992, International journal of radiation oncology, biology, physics.

[18]  A G Visser,et al.  Performance of a prototype fluoroscopic radiotherapy imaging system. , 1990, International journal of radiation oncology, biology, physics.

[19]  D. Hallahan,et al.  Radiation induction of immediate early genes: effectors of the radiation-stress response. , 1994, International journal of radiation oncology, biology, physics.

[20]  D P Dearnaley,et al.  A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  S. Shalev Progress in the evaluation of electronic portal imaging--taking one step at a time. , 1994, International journal of radiation oncology, biology, physics.

[22]  M van Herk,et al.  A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[24]  J Bijhold,et al.  Detection of systematic patient setup errors by portal film analysis. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  J. Lebesque,et al.  Abstracts of ASTRO proffered papers, posters, and scientific exhibit to be presentedSet-up accuracy for pelvic fields after application of a 3-d correction procedure using digital portal imaging , 1994 .

[26]  R Mohan,et al.  The role of uncertainty analysis in treatment planning. , 1991, International journal of radiation oncology, biology, physics.