An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging

Recent studies suggests that contrast ultrasound for molecular imaging or vasa vasorum (VV) assessment may be promising in identification of vulnerable plaques. However, conventional intravascular ultrasound (IVUS) transducers with frequency of 15 MHz - 60 MHz are not optimized for imaging with micro bubble contrast agents due to the ineffective micro bubble excitation at high frequencies and poor signal separation from tissue. This paper presents design and fabrication of a lateral mode transducer array with center frequency of 2 MHz for contrast enhanced IVUS (CE-IVUS) imaging, which can generate sufficient pressure to excite microbubbles more effectively and therefore could be used for dual-frequency microbubble superharmonic imaging, or `acoustic angiography'. Several commercial transducers with central frequency of 15 MHz, 20 MHz and 25 MHz were used as receivers to receive the contrast signal. In the contrast testing, the high frequency echo of the nonlinear response from microbubbles in a micro-tube with diameter of 0.2 mm was detected. The maximum contrast to noise ratio was 12.2 dB. The results show that superharmonic signals (over 9th harmonic) can be received; suggesting good resolution and signal separation in contrast enhanced IVUS imaging.

[1]  Nico de Jong,et al.  Subharmonic contrast intravascular ultrasound for vasa vasorum imaging. , 2007, Ultrasound in medicine & biology.

[2]  Paul A Dayton,et al.  Mapping microvasculature with acoustic angiography yields quantifiable differences between healthy and tumor-bearing tissue volumes in a rodent model. , 2012, Radiology.

[3]  Aloke V. Finn,et al.  Atherosclerotic Plaque Progression and Vulnerability to Rupture: Angiogenesis as a Source of Intraplaque Hemorrhage , 2005, Arteriosclerosis, thrombosis, and vascular biology.

[4]  F. Stuart Foster,et al.  Acoustic Angiography: A New Imaging Modality for Assessing Microvasculature Architecture , 2013, Int. J. Biomed. Imaging.

[5]  Jianguo Ma,et al.  Small aperture, dual frequency ultrasound transducers for intravascular contrast imaging , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[6]  M. Daemen,et al.  Novel concepts in atherogenesis: angiogenesis and hypoxia in atherosclerosis , 2009, The Journal of pathology.

[7]  N de Jong,et al.  Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border. , 1999, The American journal of cardiology.

[8]  K. Ferrara,et al.  A new imaging strategy using wideband transient response of ultrasound contrast agents , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Xiaoning Jiang,et al.  High Frequency Piezo Composites Microfabricated Ultrasound Transducers for Intravascular Imaging , 2006 .

[10]  S. Rhee,et al.  60 MHz PMN-PT based 1-3 composite transducer for IVUS imaging , 2008, 2008 IEEE Ultrasonics Symposium.

[11]  Paul A Dayton,et al.  High-resolution, high-contrast ultrasound imaging using a prototype dual-frequency transducer: In vitro and in vivo studies , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  F. T. ten Cate,et al.  Super harmonic imaging: a new imaging technique for improved contrast detection. , 2002, Ultrasound in medicine & biology.

[13]  David Zurakowski,et al.  Inhibition of plaque neovascularization reduces macrophage accumulation and progression of advanced atherosclerosis , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Nico de Jong,et al.  Contrast Harmonic Intravascular Ultrasound: A Feasibility Study for Vasa Vasorum Imaging , 2006, Investigative radiology.

[15]  K. Sueishi,et al.  Intimal neovascularization in human coronary atherosclerosis: its origin and pathophysiological significance. , 1995, Human pathology.