Use of intra-articular carbon dioxide and air for MR arthrography: a feasibility study.

During animal experiments, carbon dioxide (CO(2)) and air were used as a novel contrast agent for direct magnetic resonance arthrography (MRAr). MRAr was performed after injection of CO(2) and air in the knee joints of two pigs. MR images of phantoms containing air, CO(2) and nitrogen were compared. After intra-articular injection, both present as a signal void on various sequences and permit sharp delineation of cartilage and other adjacent structures. Despite the potential for artefact generation, only a slight susceptibility artefact was seen after injection of CO(2) and air. In phantom experiments, air, CO(2) and nitrogen demonstrated identical slight regular susceptibility artefacts at the phantom margins. CO(2) MRAr can yield high contrast between cartilage, ligaments and synovium relative to the joint compartment. Therefore, this technique might be useful as an investigational method for the evaluation of cartilage surface lesions and possibly as an alternative contrast agent for clinical use.

[1]  J. Lewin,et al.  Combined use of the intravascular blood‐pool agent, gadomer, and carbon dioxide: A novel type of double‐contrast magnetic resonance angiography (MRA) , 2005, Journal of magnetic resonance imaging : JMRI.

[2]  T. Takei,et al.  Venous air embolism during knee arthrography , 2004, Archives of Orthopaedic and Trauma Surgery.

[3]  Adam C Zoga,et al.  Indirect Magnetic Resonance Arthrography: Applications in Sports Imaging , 2003, Topics in magnetic resonance imaging : TMRI.

[4]  K. Scheffler,et al.  Optimization of signal behavior in the transition to driven equilibrium in steady‐state free precession sequences , 2002, Magnetic resonance in medicine.

[5]  M. Schweitzer,et al.  Special focus session. MR arthrography. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[6]  L. Dougherty,et al.  Effects of iodinated contrast and field strength on gadolinium enhancement: Implications for direct MR arthrography , 2002, Journal of magnetic resonance imaging : JMRI.

[7]  L. White,et al.  Diagnosis of recurrent meniscal tears: prospective evaluation of conventional MR imaging, indirect MR arthrography, and direct MR arthrography. , 2002, Radiology.

[8]  W. Bautz,et al.  Direct MR arthrography of the shoulder: 2D vs. 3D gradient-echo imaging. , 2001, Magnetic resonance imaging.

[9]  C. Gerber,et al.  MR arthrography of the glenohumeral joint: two concentrations of gadoteridol versus Ringer solution as the intraarticular contrast material. , 2001, Radiology.

[10]  D G Nishimura,et al.  MR imaging of articular cartilage using driven equilibrium , 1999, Magnetic resonance in medicine.

[11]  N. Goudsouzian,et al.  Carbon Dioxide Embolism During Hip Arthography in an Infant , 1998 .

[12]  K. Hahn,et al.  Prospective evaluation of MR arthrography performed with high-volume intraarticular saline enhancement in patients with recurrent anterior dislocations of the shoulder. , 1998, AJR. American journal of roentgenology.

[13]  H. Genant,et al.  Indirect MR arthrography: techniques and applications , 1998, European Radiology.

[14]  C. Gückel,et al.  The rope ladder: an uncommon artifact and potential pitfall in MR arthrography of the shoulder. , 1997, AJR. American journal of roentgenology.

[15]  M. Zanetti,et al.  Contrast media in MR arthrography of the glenohumeral joint: intra-articular gadopentetate vs saline: preliminary results , 1997, European Radiology.

[16]  I. Hawkins,et al.  Carbon dioxide digital subtraction angiography: expanding applications and technical evolution. , 1995, AJR. American journal of roentgenology.

[17]  R. Patten Vacuum phenomenon: a potential pitfall in the interpretation of gradient-recalled-echo MR images of the shoulder. , 1994, AJR. American journal of roentgenology.

[18]  B. Flannigan,et al.  MR arthrography of the shoulder: comparison with conventional MR imaging. , 1990, AJR. American journal of roentgenology.

[19]  J. Mink,et al.  Air or CO2 for knee arthrography? , 1980, AJR. American journal of roentgenology.

[20]  J. Rehn,et al.  [The technique of arthroscopy with nitrous oxide insufflation (author's transl)]. , 1978, Unfallheilkunde.