Passive magnetic shielding in MRI-Linac systems

Passive magnetic shielding refers to the use of ferromagnetic materials to redirect magnetic field lines away from vulnerable regions. An application of particular interest to the medical physics community is shielding in MRI systems, especially integrated MRI-linear accelerator (MRI-Linac) systems. In these systems, the goal is not only to minimize the magnetic field in some volume, but also to minimize the impact of the shield on the magnetic fields within the imaging volume of the MRI scanner. In this work, finite element modelling was used to assess the shielding of a side coupled 6 MV linac and resultant heterogeneity induced within the 30 cm diameter of spherical volume (DSV) of a novel 1 Tesla split bore MRI magnet. A number of different shield parameters were investigated; distance between shield and magnet, shield shape, shield thickness, shield length, openings in the shield, number of concentric layers, spacing between each layer, and shield material. Both the in-line and perpendicular MRI-Linac configurations were studied. By modifying the shield shape around the linac from the starting design of an open ended cylinder, the shielding effect was boosted by approximately 70% whilst the impact on the magnet was simultaneously reduced by approximately 10%. Openings in the shield for the RF port and beam exit were substantial sources of field leakage; however it was demonstrated that shielding could be added around these openings to compensate for this leakage. Layering multiple concentric shield shells was highly effective in the perpendicular configuration, but less so for the in-line configuration. Cautious use of high permeability materials such as Mu-metal can greatly increase the shielding performance in some scenarios. In the perpendicular configuration, magnetic shielding was more effective and the impact on the magnet lower compared with the in-line configuration.

[1]  Paul Keall,et al.  Impact of the MLC on the MRI field distortion of a prototype MRI-linac. , 2013, Medical physics.

[2]  F. Schweizer MAGNETIC SHIELDING FACTORS OF A SYSTEM OF CONCENTRIC SPHERICAL SHELLS , 1962 .

[3]  A. Mager,et al.  Magnetic Shielding Efficiencies of Cylindrical Shells with Axis Parallel to the Field , 1968 .

[4]  B G Fallone,et al.  The design of a simulated in-line side-coupled 6 MV linear accelerator waveguide. , 2010, Medical physics.

[5]  C. Ménard,et al.  Introduction: Systems for magnetic resonance image guided radiation therapy. , 2014, Seminars in radiation oncology.

[6]  T. Sumner,et al.  Convectional magnetic shielding , 1987 .

[7]  B G Fallone,et al.  Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system. , 2012, Medical physics.

[8]  Dong-Chul Park,et al.  Shielding factors of grain oriented 3% SiFe cylinder , 1999, IEEE International Magnetics Conference.

[9]  Jan J W Lagendijk,et al.  MRI/linac integration. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  I. Sasada,et al.  A new estimation of the axial shielding factors for multishell cylindrical shields , 2000 .

[11]  Ling Xia,et al.  A Hybrid Field-Harmonics Approach for Passive Shimming Design in MRI , 2011, IEEE Transactions on Applied Superconductivity.

[12]  Rebecca Fahrig,et al.  Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy. , 2016, Medical physics.

[13]  W. G. Wadey Magnetic Shielding with Multiple Cylindrical Shells , 1956 .

[14]  Installation of the 1.5 T MRI accelerator next to clinical accelerators: impact of the fringe field. , 2009, Physics in medicine and biology.

[15]  F. Elhalouani,et al.  The effect of cold work on structure and properties of AISI 304 stainless steel , 2008 .

[16]  R. Ilmoniemi,et al.  Design, construction, and performance of a large-volume magnetic shield , 1982 .

[17]  B G Fallone,et al.  Magnetic decoupling of the linac in a low field biplanar linac-MR system. , 2010, Medical physics.

[18]  M. Bock,et al.  An MRI-Compatible Surgical Robot for Precise Radiological Interventions , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[19]  Rebecca Fahrig,et al.  A novel electron accelerator for MRI-Linac radiotherapy. , 2016, Medical physics.

[20]  Rebecca Fahrig,et al.  A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators. , 2011, Medical physics.

[21]  N J Pelc,et al.  A truly hybrid interventional MR/X‐ray system: Feasibility demonstration , 2001, Journal of magnetic resonance imaging : JMRI.

[22]  B G Fallone,et al.  Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac. , 2010, Medical physics.

[23]  Y. Reutov Choice of the Number of Shells for a Spherical Magnetostatic Shield , 2001 .

[24]  Stuart Crozier,et al.  The Australian magnetic resonance imaging-linac program. , 2014, Seminars in radiation oncology.

[25]  Rebecca Fahrig,et al.  Thermal limits on MV x‐ray production by bremsstrahlung targets in the context of novel linear accelerators , 2017, Medical physics.

[26]  T. Young,et al.  Natural magick: in twenty books [...] wherein are set forth all the riches and delights of the natural sciences , 2009 .

[27]  Stan Majewski,et al.  Simultaneous MRI and PET imaging of a rat brain. , 2006, Physics in medicine and biology.

[28]  A. Rücker VII.On the magnetic shielding of concentric spherical shells , 1894 .

[29]  J Yun,et al.  Brushed permanent magnet DC MLC motor operation in an external magnetic field. , 2010, Medical physics.