Radiation exposure during transmission measurements: comparison between CT- and germanium-based techniques with a current PET scanner

In positron emission tomographic (PET) scanning, transmission measurements for attenuation correction are commonly performed by using external germanium-68 rod sources. Recently, combined PET and computed tomographic (CT) scanners have been developed in which the CT data can be used for both anatomical-metabolic image formation and attenuation correction of the PET data. The purpose of this study was to evaluate the difference between germanium- and CT-based transmission scanning in terms of their radiation doses by using the same measurement technique and to compare the doses that patients receive during brain, cardiac and whole-body scans. Measurement of absorbed doses to organs was conducted by using a Rando Alderson phantom with thermoluminescent dosimeters. Effective doses were calculated according to the guidelines in the International Commission on Radiation Protection Publication Number 60. Compared with radionuclide doses used in routine 2-[fluorine-18]-fluoro-2-deoxy-d-glucose PET imaging, doses absorbed during germanium-based transmission scans were almost negligible. On the other hand, absorbed doses from CT-based transmission scans were significantly higher, particularly with a whole-body scanning protocol. Effective doses were 8.81 mSv in the high-speed mode and 18.97 mSv in the high-quality mode for whole-body CT-based transmission scans. These measurements revealed that the doses received by a patient during CT-based transmission scanning are more than those received in a typical PET examination. Therefore, the radiation doses represent a limitation to the generalised use of CT-based transmission measurements with current PET/CT scanner systems.

[1]  P. Jarritt,et al.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease , 1997, European Journal of Nuclear Medicine.

[2]  D W. Townsend,et al.  Combined PET/CT Imaging in Oncology. Impact on Patient Management. , 2000, Clinical positron imaging : official journal of the Institute for Clinical P.E.T.

[3]  M. Defrise,et al.  Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction , 1999, European Journal of Nuclear Medicine.

[4]  Cyrill Burger,et al.  Recurrent laryngeal nerve palsy in patients with lung cancer: detection with PET-CT image fusion -- report of six cases. , 2002, Radiology.

[5]  A. Buck,et al.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[6]  M. Cooper,et al.  Radiation dose to the bladder wall from 2-[18F]fluoro-2-deoxy-D-glucose in adult humans. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  J Hashimoto,et al.  Scatter and attenuation correction in technetium-99m brain SPECT. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  R. Wahl,et al.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  J. S. Lee,et al.  Dynamic evaluation of absorbed dose to the bladder wall with a balloon-bladder phantom during a study using [18F]fluorodeoxyglucose positron emission imaging , 2002, Nuclear medicine communications.

[10]  A. Jurik,et al.  Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni , 1996, Skeletal Radiology.

[11]  B. Tsui,et al.  Performance characteristics of transmission imaging using a uniform sheet source with parallel-hole collimation. , 1992, Medical physics.

[12]  H. M. Deloar,et al.  Internal absorbed dose estimation by a TLD method for 18F-FDG and comparison with the dose estimates from whole body PET. , 1999, Physics in medicine and biology.

[13]  M. Stabin,et al.  MIRD Pamphlet No. 14 revised: A dynamic urinary bladder model for radiation dose calculations. Task Group of the MIRD Committee, Society of Nuclear Medicine. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  N. Mullani,et al.  A segmented attenuation correction for PET. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  D. Bailey Transmission scanning in emission tomography , 1998, European Journal of Nuclear Medicine.

[16]  D W Townsend,et al.  A combined PET/CT scanner: the choices. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  Valerie Treyer,et al.  CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[18]  C. Meltzer,et al.  Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner , 2000, Clinical nuclear medicine.

[19]  Arnaud Peltier,et al.  Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters , 1998, European Journal of Nuclear Medicine.

[20]  Norbert Avril,et al.  Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images , 1997, European Journal of Nuclear Medicine.

[21]  D. Visvikis,et al.  CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[22]  Masatoshi Itoh,et al.  Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-d- glucose using whole-body positron emission tomography and magnetic resonance imaging , 1998, European Journal of Nuclear Medicine.

[23]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  Ora Israel,et al.  Combined functional and structural evaluation of cancer patients with a hybrid camera-based PET/CT system using (18)F-FDG. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Thomas F Hany,et al.  PET diagnostic accuracy: improvement with in-line PET-CT system: initial results. , 2002, Radiology.

[26]  D Visvikis,et al.  Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PET. , 2001, European journal of nuclear medicine.