Tissue-like phantoms for quantitative birefringence imaging.

Birefringence imaging, including polarization sensitive optical coherence tomography (PS-OCT), can provide valuable insight into the microscopic structure and organization of many biological tissues. In this paper, we report on a method to fabricate tissue-like birefringence phantoms for such imaging modalities. We utilize the photo-elastic effect, wherein birefringence is induced by stretching a polymer sample after heating it above its glass-transition temperature. The cooled samples stably exhibit homogeneous birefringence, and were assembled into phantoms containing multiple well-defined regions of distinct birefringence. We present planar slab phantoms for microscopy applications and cylindrical phantoms for catheter-based imaging and demonstrate quantitative analysis of the birefringence within individual regions of interest. Birefringence phantoms enable testing, validating, calibrating, and improving PS-OCT acquisition systems and reconstruction strategies.

[1]  Martin Villiger,et al.  Spectral binning for mitigation of polarization mode dispersion artifacts in catheter-based optical frequency domain imaging. , 2013, Optics express.

[2]  C. M. Roland,et al.  Elasticity of natural rubber networks , 1996 .

[3]  B. Pogue,et al.  Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. , 2006, Journal of biomedical optics.

[4]  Guy Lamouche,et al.  Artery phantoms for intravascular optical coherence tomography: diseased arteries , 2013, Journal of biomedical optics.

[5]  U. Schmidt-Erfurth,et al.  Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography. , 2008, Optics express.

[6]  M. V. van Gemert,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.

[7]  J. Fujimoto,et al.  Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging , 1992 .

[8]  J. Nelson,et al.  High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin. , 2000, Optics letters.

[9]  Brett E. Bouma,et al.  Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivo , 2016, Science Translational Medicine.

[10]  Bernhard Baumann,et al.  Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications , 2017 .

[11]  Yoshiaki Yasuno,et al.  Passive component based multifunctional Jones matrix swept source optical coherence tomography for Doppler and polarization imaging. , 2012, Optics letters.

[12]  Rebekah Drezek,et al.  Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom. , 2010, Optics letters.

[13]  Kelsey M. Kennedy,et al.  Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography , 2012, Biomedical optics express.

[14]  Brett E. Bouma,et al.  First-in-man assessment of plaque rupture by polarization-sensitive optical frequency domain imaging in vivo , 2016, European heart journal.

[15]  Sang June Yoon,et al.  In vivo imaging of human burn injuries with polarization-sensitive optical coherence tomography. , 2012, Journal of biomedical optics.

[16]  D. Sampson,et al.  Deep tissue volume imaging of birefringence through fibre-optic needle probes for the delineation of breast tumour , 2016, Scientific Reports.

[17]  SANAZ ALALI,et al.  Rapid wide-field Mueller matrix polarimetry imaging based on four photoelastic modulators with no moving parts. , 2016, Optics letters.

[18]  Martin Villiger,et al.  Degree of polarization (uniformity) and depolarization index: unambiguous depolarization contrast for optical coherence tomography. , 2015, Optics letters.

[19]  Daniel X. Hammer,et al.  Retina-simulating phantom for optical coherence tomography , 2013, Journal of biomedical optics.

[20]  B E Bouma,et al.  High-speed polarization sensitive optical frequency domain imaging with frequency multiplexing. , 2008, Optics express.

[21]  Michael Pircher,et al.  Polarization-Sensitive Optical Coherence Tomography and Conventional Retinal Imaging Strategies in Assessing Foveal Integrity in Geographic Atrophy. , 2015, Investigative ophthalmology & visual science.

[22]  Stephen A. Boppart,et al.  Differentiation of Ex Vivo Human Breast Tissue using Polarization-Sensitive Optical Coherence Tomography , 2014 .

[23]  Martin Villiger,et al.  Artifacts in polarization-sensitive optical coherence tomography caused by polarization mode dispersion. , 2013, Optics letters.

[24]  Barry Cense,et al.  Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography. , 2004, Burns : journal of the International Society for Burn Injuries.

[25]  Y. Yasuno,et al.  Repeatability of corneal phase retardation measurements by polarization-sensitive optical coherence tomography. , 2015, Investigative ophthalmology & visual science.

[26]  Gang Yao,et al.  Mapping local retardance in birefringent samples using polarization sensitive optical coherence tomography. , 2012, Optics letters.

[27]  Chuanmao Fan,et al.  Imaging myocardial fiber orientation using polarization sensitive optical coherence tomography , 2013, Biomedical optics express.

[28]  Shuichi Makita,et al.  Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging. , 2010, Optics express.

[29]  B E Bouma,et al.  Single-detector polarization-sensitive optical frequency domain imaging using high-speed intra A-line polarization modulation. , 2008, Optics letters.

[30]  Brett E Bouma,et al.  Measurement of collagen and smooth muscle cell content in atherosclerotic plaques using polarization-sensitive optical coherence tomography. , 2007, Journal of the American College of Cardiology.

[31]  C. Hitzenberger,et al.  Polarization sensitive optical coherence tomography - a review [Invited]. , 2017, Biomedical optics express.

[32]  Zhenyang Ding,et al.  Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix. , 2015, Biomedical optics express.

[33]  Jean-Pierre Bouchard,et al.  Toward an automated method for optical coherence tomography characterization , 2015, Journal of biomedical optics.

[34]  Linbo Liu,et al.  Spectral estimation optical coherence tomography for axial super-resolution. , 2015, Optics express.

[35]  Martin Villiger,et al.  Longitudinal, 3D Imaging of Collagen Remodeling in Murine Hypertrophic Scars In Vivo Using Polarization-Sensitive Optical Frequency Domain Imaging. , 2015, The Journal of investigative dermatology.

[36]  A. Fercher,et al.  Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography. , 2001, Optics express.

[37]  Barry Cense,et al.  Real-time multi-functional optical coherence tomography. , 2003, Optics express.

[38]  Brendan F Kennedy,et al.  Structured three-dimensional optical phantom for optical coherence tomography. , 2011, Optics express.