Deep UV laser-induced fluorescence for pharmaceutical cleaning validation.

Cleaning verification and validation is a requirement in the pharmaceutical industry. Due to the limited number of mobile devices that do effective and accurate onsite cleaning verification, it is mostly done via lab-based quality control techniques. These techniques, such as High-Performance Liquid Chromatography (HPLC) or Total Organic Carbon, often lead to extending the validation of cleaning by days. The void of more sensitive, accurate, and portable instruments to verify cleaning onsite has to be filled. The article discusses the use of Deep Ultra Violet (DUV) laser-induced fluorescence for detecting carryover of Active Pharmaceutical Ingredients (APIs) and detergents onsite. A modified spectrometer was used as an offsite bench type prototype for analyzing trace samples of API and cleaning detergents with various substrates. Even if the API to be detected has a low fluorescence efficiency, the specificity of the technique allows API traces having concentrations as low as ≈0.20 μg/cm2 to be identified. The work also shows the possibility of using a probe for validating cleaning of hard to reach areas using DUV laser-induced fluorescence. DUV laser-induced fluorescence of trace API over any polymer/glass substrate has better Signal to Background Ratio (SBR) compared to FTIR absorption techniques. Processing times of DUV laser-induced fluorescence trace detection are shown to be much less than swab based methods.

[1]  Joseph N. Tanyous Cleaning Validation: Complete Guide for Health - Based Approach in Chemical Cross - Contamination Risk Assessment , 2018, PDA Journal of Pharmaceutical Science and Technology.

[2]  M. Vaher,et al.  In Situ Determination of Illegal Drugs in Oral Fluid by Portable Capillary Electrophoresis with Deep UV Excited Fluorescence Detection. , 2018, Analytical chemistry.

[3]  A. Blasko,et al.  Cleaning verification: Exploring the effect of the cleanliness of stainless steel surface on sample recovery , 2017, Journal of pharmaceutical and biomedical analysis.

[4]  F. Schmitt,et al.  Fluorescence-optical handheld non-contact sensor for rapid cleaning validation of surfaces , 2015 .

[5]  S. Engelsen,et al.  Fluorescence Spectroscopy in Process Analytical Technology (PAT): Simultaneous Quantification of Two Active Pharmaceutical Ingredients in a Tablet Formulation , 2015, Applied spectroscopy.

[6]  Jürgen Popp,et al.  Ultrasensitive fiber enhanced UV resonance Raman sensing of drugs. , 2013, Analytical chemistry.

[7]  P. Cullen,et al.  Feasibility of near Infrared Chemical Imaging for Pharmaceutical Cleaning Verification , 2013 .

[8]  Dana N. Peles,et al.  Rapid at-line pharmaceutical cleaning verification using a novel light induced fluorescence (LIF) sensor. , 2013, Journal of pharmaceutical and biomedical analysis.

[9]  R. D. Reid,et al.  Improved sensing using simultaneous deep-UV Raman and fluorescence detection-II , 2012, Defense + Security Symposium.

[10]  Sergey Piletsky,et al.  Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine , 2010, The Journal of pharmacy and pharmacology.

[11]  Rohit Bhartia,et al.  Classification of Organic and Biological Materials with Deep Ultraviolet Excitation , 2008, Applied spectroscopy.

[12]  B. Perston,et al.  Grazing-Angle Fiber-Optic IRRAS for in Situ Cleaning Validation , 2005 .

[13]  David Ian Wilson,et al.  Challenges in Cleaning: Recent Developments and Future Prospects , 2005 .

[14]  M. Storrie-Lombardi,et al.  Hollow cathode ion lasers for deep ultraviolet Raman spectroscopy and fluorescence imaging , 2001 .

[15]  Mauricio S. Baptista,et al.  Fluorescence in Pharmaceutics and Cosmetics , 2019, Springer Series on Fluorescence.

[16]  M. Thomson Mid-IR Spectroscopy as a Tool for Cleanliness Validation , 2015 .