The effect of articular conformity and the size of the humeral head component on laxity and motion after glenohumeral arthroplasty. A study in cadavera.

We used a cadaveric model to examine the mechanical effects of changes in the conformity of the articular surfaces and the size of the humeral head component in glenohumeral arthroplasty. The experimental system permitted a manual clinical examination of the glenohumeral joint while sensors monitored the humeroscapular position and orientation as well as the forces and torques applied by the examiner. Four preparations were compared: an anatomical humeroscapular preparation and three glenohumeral arthroplasty preparations (one with anatomically sized components and a radius of curvature of the glenoid that was four millimeters larger than that of the humeral head, one with anatomically sized components and a radius of curvature of the glenoid that was equal to that of the humeral head, and one with a non-anatomical, large humeral head component and a radius of curvature of the glenoid that was equal to that of the humeral head). All motions, including flexion, external and internal rotation, and maximum elevation, were diminished with use of the non-anatomical, large humeral head component. Laxity of the joint on drawer and sulcus tests was not affected by the conformity of the articular surfaces but was decreased significantly by implantation of the large humeral head component. The kinematics of the glenohumeral joint were not markedly altered by reduction of the uniformity between the articular surfaces of the prosthetic components. In all preparations, obligate displacement of the humeral head associated with a passive range of motion occurred at smaller angles with the large humeral head component.

[1]  C. Neer Replacement arthroplasty for glenohumeral osteoarthritis. , 1974, The Journal of bone and joint surgery. American volume.

[2]  S M Howell,et al.  Normal and abnormal mechanics of the glenohumeral joint in the horizontal plane. , 1988, The Journal of bone and joint surgery. American volume.

[3]  C. Neer,et al.  Recent experience in total shoulder replacement. , 1982, The Journal of bone and joint surgery. American volume.

[4]  R. Hawkins,et al.  Glenohumeral osteoarthrosis. A late complication of the Putti-Platt repair. , 1990, The Journal of bone and joint surgery. American volume.

[5]  J A Sidles,et al.  Translation of the humeral head on the glenoid with passive glenohumeral motion. , 1990, The Journal of bone and joint surgery. American volume.

[6]  N. Poppen,et al.  Normal and abnormal motion of the shoulder. , 1976, The Journal of bone and joint surgery. American volume.

[7]  Frederick A. Matsen,et al.  The technique of glenohumeral arthroplasty , 1991 .

[8]  F A Matsen,et al.  Glenoid loosening in total shoulder arthroplasty. Association with rotator cuff deficiency. , 1988, The Journal of arthroplasty.

[9]  J A Sidles,et al.  Laxity of the normal glenohumeral joint: A quantitative in vivo assessment. , 1992, Journal of shoulder and elbow surgery.

[10]  F A Matsen,et al.  Total shoulder arthroplasty. , 1987, The Journal of bone and joint surgery. American volume.

[11]  J A Sidles,et al.  The role of the rotator interval capsule in passive motion and stability of the shoulder. , 1992, The Journal of bone and joint surgery. American volume.