Experimental study of the start-up of a fuel cell stack for backup power application

The transient response of proton exchange membrane fuel cells during start-up is an important issue for backup power systems which require a very short start-up time in order to limit the use of batteries during a blackout. The start-up procedure of a ten cells stack was studied: in the first stage the cathode channel initially filled with nitrogen was supplied with oxygen in open circuit then in the second stage it was connected to the load. The influences of the current time-profile (step or ramp), the cell voltage at the connection and the gas flow rates on the voltage variation were investigated. It was found that the voltage value during the filling of the cathode is not sufficient to determine which fraction of the cathode was filled with oxygen. In most cases, high oxygen flow rates allow reducing the start-up time of the stack. Furthermore, for fixed current density and stoichiometric coefficients it was found that a minimum start-up time exits. The analysis of transient response to current steps showed that around 70% of the maximum electrical power was available less than 2 s after the beginning of the start-up procedure.

[1]  Junxiao Wu,et al.  Study of the effects of various parameters on the transient current density at polymer electrolyte membrane fuel cell start-up , 2009 .

[2]  Hiroyuki Uchida,et al.  Response of Specific Resistance Distribution in Electrolyte Membrane to Load Change at PEFC Operation , 2007 .

[3]  K. Min,et al.  Transient response of a unit proton-exchange membrane fuel cell under various operating conditions , 2008 .

[4]  Steffen Møller-Holst,et al.  Effect of gas composition and gas utilisation on the dynamic response of a proton exchange membrane fuel cell , 2008 .

[5]  Changchun Ke,et al.  Experimental and modeling study on water dynamic transport of the proton exchange membrane fuel cell under transient air flow and load change , 2010 .

[6]  Guilin Hu,et al.  Transient computation fluid dynamics modeling of a single proton exchange membrane fuel cell with serpentine channel , 2007 .

[7]  Siew-Chong Tan,et al.  Characterization of the dynamic response of proton exchange membrane fuel cells A numerical study , 2010 .

[8]  Jérôme Dillet,et al.  Experimental characterization of internal currents during the start-up of a proton exchange membrane , 2011 .

[9]  Xianguo Li,et al.  Numerical analysis of dynamic processes in fully humidified PEM fuel cells , 2007 .

[10]  G. Maranzana,et al.  Internal currents in response to a load change during fuel cell start-up , 2012 .

[11]  C. Bordons,et al.  Development and experimental validation of a PEM fuel cell dynamic model , 2007 .

[12]  Chao-Yang Wang,et al.  Dynamics of polymer electrolyte fuel cells undergoing load changes , 2006 .

[13]  Wei-Mon Yan,et al.  Transient analysis of reactant gas transport and performance of PEM fuel cells , 2005 .

[14]  Chao-Yang Wang,et al.  Transient analysis of polymer electrolyte fuel cells , 2005 .

[15]  Sirivatch Shimpalee,et al.  The effect of stoichiometry on dynamic behavior of a proton exchange membrane fuel cell (PEMFC) during load change , 2004 .

[16]  Yann Bultel,et al.  Monodimensional modeling and experimental study of the dynamic behavior of proton exchange membrane fuel cell stack operating in dead-end mode , 2007 .