Projection angle dependence in grating-based X-ray dark-field imaging of ordered structures.

Over the recent years X-ray differential phase-contrast imaging was developed for the hard X-ray regime as produced from laboratory X-ray sources. The technique uses a grating-based Talbot-Lau interferometer and was shown to yield image contrast gain, which makes it very interesting to the fields of medical imaging and non-destructive testing, respectively. In addition to X-ray attenuation contrast, the differential phase-contrast and dark-field images provide different structural information about a specimen. For the dark-field even at length scales much smaller than the spatial resolution of the imaging system. Physical interpretation of the dark-field information as present in radiographic and tomographic (CT) images requires a detailed look onto the geometric orientation between specimen and the setup. During phase-stepping the drop in intensity modulation, due to local scattering effects within the specimen is reproduced in the dark-field signal. This signal shows strong dependencies on micro-porosity and micro-fibers if these are numerous enough in the object. Since a grating-interferometer using a common unidirectional line grating is sensitive to X-ray scattering in one plane only, the dark-field image is influenced by the fiber orientations with respect to the grating bars, which can be exploited to obtain anisotropic structural information. With this contribution, we attempt to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).

[1]  Juergen Mohr,et al.  Soft X-ray lithography of high aspect ratio SU8 submicron structures , 2008 .

[2]  Alex Dommann,et al.  Orientation-selective X-ray dark field imaging of ordered systems , 2012 .

[3]  Urs Sennhauser,et al.  Sub-pixel porosity revealed by x-ray scatter dark field imaging , 2011 .

[4]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[5]  Han Wen,et al.  Spatial Harmonic Imaging of X-ray Scattering—Initial Results , 2008, IEEE Transactions on Medical Imaging.

[6]  Atsushi Momose,et al.  Phase Tomography by X-ray Talbot Interferometry for Biological Imaging , 2006 .

[7]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[8]  Franz Pfeiffer,et al.  Directional x-ray dark-field imaging of strongly ordered systems , 2010 .

[9]  Timm Weitkamp,et al.  X-ray vector radiography for bone micro-architecture diagnostics , 2012, Physics in medicine and biology.

[10]  Franz Pfeiffer,et al.  Directional x-ray dark-field imaging , 2010, Physics in medicine and biology.

[11]  Han Wen,et al.  Fourier X-ray scattering radiography yields bone structural information. , 2009, Radiology.

[12]  Thilo Michel,et al.  Spectroscopic dark-field imaging using a grating-based Talbot-Lau interferometer , 2012, Medical Imaging.

[13]  Franz Pfeiffer,et al.  Quantitative x-ray dark-field computed tomography , 2010, Physics in medicine and biology.

[14]  C. David,et al.  The partial Talbot effect and its use in measuring the coherence of synchrotron X-rays. , 2004, Journal of synchrotron radiation.

[15]  Urs Sennhauser,et al.  Sensing small angle scattering with an X-ray grating interferometer , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[16]  A. Momose,et al.  On the origin of visibility contrast in x-ray Talbot interferometry. , 2010, Optics express.

[17]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.