X-ray imaging glass micro-pore optics

Glass micro-pore optics technology, developed over the last years for planetary X-ray imagers, has been used to assemble optical modules in approximation of a Wolter-I configuration. These tandems of glass sectors consist of hundreds of square, millimetre sized, multi-fibres that each contain more than a thousand, 3 μm thin, X-ray mirrors with a surface roughness suitable for application at medium X-ray energies. The performance of the tandems can be traced back to the quality of the individual fibres. Extensive X-ray testing has been done on all constituents, from several fibres up to tandem level, using pencil beam and, for the first time, full beam illumination at PANTER. The results of these campaigns and of reflectometry measurements are discussed in this paper and have been used throughout the technology development program to monitor the X-ray performance. It will be shown that the quality of focussing micro-pore X-ray optics is now high enough to achieve an angular resolution of several arc minutes and that the multi-fibres are as good as 20 arc seconds, demonstrating the potential of this technology. The tandems can be combined and assembled into larger geometries, hence forming a very light and compact X-ray lens of ~200 mm diameter and a focal length of 1 m. This is part of an ESA breadboard program discussed elsewhere in this conference.

[1]  Keith A. Nugent,et al.  On the concentration, focusing, and collimation of x‐rays and neutrons using microchannel plates and configurations of holes , 1989 .

[2]  Elmar Pfeffermann,et al.  The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera , 2001 .

[3]  H. Wolter Spiegelsysteme streifenden Einfalls als abbildende Optiken für Röntgenstrahlen , 1952 .

[4]  Marco Beijersbergen,et al.  Development of micro-pore optics for x-ray applications , 2005, SPIE Optics + Photonics.

[5]  George W. Fraser,et al.  Hard X-ray imaging with microchannel plate optics , 1998 .

[6]  Marcos Bavdaz,et al.  HERMES: an imaging x-ray fluorescence spectrometer for the BepiColombo mission to Mercury , 2001, SPIE Optics + Photonics.

[7]  Elmar Pfeffermann,et al.  X-Ray Calibration Of The Rosat Position Sensitive Proportional Counter , 1988, Optics & Photonics.

[8]  J E Lees,et al.  Metrology and modeling of microchannel plate x-ray optics. , 1997, Applied optics.

[9]  Marcos Bavdaz,et al.  Microchannel-plate-based x-ray optics , 1999, Optics & Photonics.

[10]  Marco Beijersbergen,et al.  Development of x-ray pore optics: novel high-resolution silicon millipore optics for XEUS and ultralow mass glass micropore optics for imaging and timing , 2004, SPIE Optics + Photonics.

[11]  Michael Krumrey,et al.  High-accuracy detector calibration at the PTB four-crystal monochromator beamline , 2001 .

[12]  Mark R. Sims,et al.  X-ray focusing using microchannel plates , 1992, Optics & Photonics.

[13]  Marcos Bavdaz,et al.  Developments in glass micropore optics for x-ray applications , 2006, SPIE Astronomical Telescopes + Instrumentation.