Electrical capacitance tomography with a non-circular sensor using the dbar method

In this paper, a new treatment of the dbar method for electrical capacitance tomography with a non-circular sensor is presented. It is a direct algorithm of image reconstruction and the gray value at any pixel of the reconstructed image is obtained directly and independently. The major calculations of image reconstruction in the dbar method were implemented in a circular sensor. As a result, complicated calculations of the scattering transform required by a non-circular sensor were avoided. A unique conformal transformation was used to map a circular sensor onto a non-circular sensor, e.g. a square sensor. In the experiments, a square sensor was constructed and the reconstructed results validated the feasibility and effectiveness of the dbar method in electrical capacitance tomography with a non-circular sensor.

[1]  D. Geselowitz An application of electrocardiographic lead theory to impedance plethysmography. , 1971, IEEE transactions on bio-medical engineering.

[2]  L. Ahlfors Complex Analysis , 1979 .

[3]  A. Nachman,et al.  Global uniqueness for a two-dimensional inverse boundary value problem , 1996 .

[4]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[5]  Wuliang Yin,et al.  A pre-iteration method for the inverse problem in electrical impedance tomography , 2003, Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412).

[6]  Christopher J. Zarowski,et al.  An Introduction to Numerical Analysis for Electrical and Computer Engineers: Zarowski/Intro to Numerical Analysis , 2004 .

[7]  David Isaacson,et al.  Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography , 2004, IEEE Transactions on Medical Imaging.

[8]  J C Newell,et al.  Reconstructions of conductive and insulating targets using the D-bar method on an elliptical domain. , 2007, Physiological measurement.

[9]  P. Senior,et al.  Investigation of batch fluidized-bed drying by mathematical modeling, CFD simulation and ECT measurement , 2008 .

[10]  Cuiping Wang,et al.  Experimental study on gas–solids flows in a circulating fluidised bed using electrical capacitance tomography , 2008 .

[11]  Sheng Liu,et al.  Preliminary study on ECT imaging of flames in porous media , 2008 .

[12]  Zhang Cao,et al.  Electrical impedance tomography with an optimized calculable square sensor. , 2008, The Review of scientific instruments.

[13]  Alberto J. Palma,et al.  Development of an Electrical Capacitance Tomography system using four rotating electrodes , 2008 .

[14]  Lijun Xu,et al.  Image reconstruction technique of electrical capacitance tomography for low-contrast dielectrics using Calderon's method , 2009 .

[15]  S. Schmitt,et al.  The factorization method for EIT in the case of mixed inclusions , 2009 .