A Semi-Autonomous Stereotactic Brain Biopsy Robot With Enhanced Safety

In stereotactic brain biopsy, operating the needle accurately and taking the biopsy specimen safely are two major challenges for ensuring the success of the surgical procedure. Considering this fact, surgical robots offering high accuracy and precision have been developed for neurosurgery including brain biopsy. Typical brain biopsy robots are only commanded to adjust the needle's pose before inserting the needle manually by a neurosurgeon. In the literature, there exists no robotic system that is competent to complete the needle insertion task autonomously. To move a step forward, a novel biopsy module for brain biopsy is first designed and fabricated in this paper. The biopsy module can be automated to complete a series of tasks such as inserting the needle, generating and controlling the aspiration pressure for specimen acquisition, and rotating the cannula for side-cutting. The biopsy module is further integrated with a cost-effective and lightweight UR5 robot and an optical tracking system to improve the autonomy, leading to a stereotactic neuronavigation system. Kinematic relationships of the involved elements are established via a calibration process. A quadratic programming based approach equipped with a virtual potential field method is implemented to safely control the robot with joint-limit avoidance and obstacle avoidance capabilities. The experimentation of the brain biopsy robot is performed, demonstrating that the developed robotic system has potential applicability in the brain biopsy surgery.

[1]  Giancarlo Ferrigno,et al.  Accurate multi-robot targeting for keyhole neurosurgery based on external sensor monitoring , 2012, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  E. Spiegel,et al.  Stereotaxic Apparatus for Operations on the Human Brain. , 1947, Science.

[3]  Yunong Zhang,et al.  Repetitive Motion Planning and Control of Redundant Robot Manipulators , 2013 .

[4]  D. Dlaka,et al.  Brain biopsy performed with the RONNA G3 system: a case study on using a novel robotic navigation device for stereotactic neurosurgery , 2018, The international journal of medical robotics + computer assisted surgery : MRCAS.

[5]  Thomas Czech,et al.  A novel miniature robotic device for frameless implantation of depth electrodes in refractory epilepsy. , 2017, Journal of neurosurgery.

[6]  James M. Drake,et al.  ISG Viewing Wand System , 1994 .

[7]  D. Roberts,et al.  Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety. , 2012, Journal of neurosurgery.

[8]  Abhilash Pandya,et al.  The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[9]  Russell H. Taylor,et al.  A Steady-Hand Robotic System for Microsurgical Augmentation , 1999, Int. J. Robotics Res..

[10]  D Glauser,et al.  Neurosurgical robot Minerva: first results and current developments. , 1995, Journal of image guided surgery.

[11]  V. Mok,et al.  A Sequential Comparison on the Risk of Haemorrhage with Different Sizes of Biopsy Needles for Stereotactic Brain Biopsy , 2014, Stereotactic and Functional Neurosurgery.

[12]  Giancarlo Ferrigno,et al.  Adaptive Hands-On Control for Reaching and Targeting Tasks in Surgery , 2015 .

[13]  M S Eljamel Validation of the PathFinder™ neurosurgical robot using a phantom , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[14]  Patrick Toussaint,et al.  The Impact of the Reference Imaging Modality, Registration Method and Intraoperative Flat-Panel Computed Tomography on the Accuracy of the ROSA® Stereotactic Robot , 2014, Stereotactic and Functional Neurosurgery.

[15]  Alexandra J Golby,et al.  Comparative effectiveness of frame-based, frameless, and intraoperative magnetic resonance imaging-guided brain biopsy techniques. , 2015, World neurosurgery.

[16]  Willi A Kalender,et al.  Development of a robotic FD‐CT‐guided navigation system for needle placement—preliminary accuracy tests , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.

[17]  S. Hayati,et al.  A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery , 1988, IEEE Transactions on Biomedical Engineering.

[18]  Alireza Gharabaghi,et al.  Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot. , 2015, Journal of neurosurgery.

[19]  S Baron,et al.  Percutaneous inner-ear access via an image-guided industrial robot system , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  Tao Zhang,et al.  Real-time motion planning for mobile robots by means of artificial potential field method in unknown environment , 2010, Ind. Robot.

[21]  Yin-Cheng Huang,et al.  Stereotactic brain biopsy: Single center retrospective analysis of complications , 2009, Clinical Neurology and Neurosurgery.

[22]  Estela Bicho,et al.  A Simple Control Approach for Stereotactic Neurosurgery Using a Robotic Manipulator , 2017 .