Comparison of retinal nerve fiber layer thickness measurements by spectral‐domain optical coherence tomography systems using a phantom eye model

To quantify differences in nerve fiber layer thickness measurements by various spectral-domain optical coherence tomography (SD-OCT) systems, we developed a phantom eye model. We tested twelve SD-OCT systems of four manufacturers. All systems combined overestimated the 49 µm thick phantom RNFL thickness on average by 18 µm. Within brands, thickness measurements differed statistically significant for one Topcon, one RTVue and one Cirrus. Between brands, thickness determined with RTVue and Topcon differed statistically significant from Cirrus and Spectralis. The maximum difference between mean thicknesses is 3.6 µm within brands and 7.7 µm between brands.

[1]  James G. Fujimoto,et al.  Retinal nerve fibre layer thickness measurement reproducibility improved with spectral domain optical coherence tomography , 2009, British Journal of Ophthalmology.

[2]  Dirk Faber,et al.  Functional optical coherence tomography : spatially resolved measurements of optical properties , 2005 .

[3]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[4]  Krishnakumar Venkateswaran,et al.  Optical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope. , 2005, Applied optics.

[5]  R. Knighton,et al.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. , 2005, Investigative ophthalmology & visual science.

[6]  J. Ramella-Roman,et al.  Dynamic eye phantom for retinal oximetry measurements. , 2009, Journal of biomedical optics.

[7]  A. Tafreshi,et al.  Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. , 2011, American journal of ophthalmology.

[8]  L. Jampol,et al.  Optical coherence tomography use in evaluation of the vitreoretinal interface: a review. , 2007, Survey of ophthalmology.

[9]  Dirk J. Faber,et al.  Measurement of the axial point spread function in scattering media using single-mode fiber-based optical coherence tomography , 2003 .

[10]  F. Medeiros,et al.  Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. , 2009, American journal of ophthalmology.

[11]  C. Cheung,et al.  Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. , 2008, Ophthalmology.

[12]  D. D. de Bruin,et al.  Optical phantoms of varying geometry based on thin building blocks with controlled optical properties. , 2010, Journal of biomedical optics.

[13]  G. Savini,et al.  Retinal Nerve Fiber Layer Thickness Measurement by Fourier-domain Optical Coherence Tomography: A Comparison Between Cirrus-HD OCT and RTVue in Healthy Eyes , 2010, Journal of glaucoma.

[14]  Dirk J. Faber,et al.  Recent developments in optical coherence tomography for imaging the retina , 2007, Progress in Retinal and Eye Research.

[15]  Ton G van Leeuwen,et al.  Doppler calibration method for Spectral Domain OCT spectrometers , 2009, Journal of biophotonics.

[16]  U. Schmidt-Erfurth,et al.  Reproducibility of high-resolution optical coherence tomography measurements of the nerve fibre layer with the new Heidelberg Spectralis optical coherence tomography , 2010, British Journal of Ophthalmology.

[17]  G. Muyo,et al.  Validation of human whole blood oximetry, using a hyperspectral fundus camera with a model eye. , 2011, Investigative ophthalmology & visual science.

[18]  Veit Sturm,et al.  Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT. , 2008, Investigative ophthalmology & visual science.

[19]  J. Fujimoto,et al.  Determination of the refractive index of highly scattering human tissue by optical coherence tomography. , 1995, Optics letters.

[20]  Robert J. Zawadzki,et al.  New developments in eye models with retina tissue phantoms for ophthalmic optical coherence tomography , 2012, BiOS.