Effect of upstream crest length on flow characteristics and discharge capacity of triangular labyrinth side weirs.

A series of laboratory experiments were performed within this study in order to investigate the hydraulic characteristics and the discharge capacity of sharp-crested triangular labyrinth side weirs with various upstream crest lengths. To conduct the experiment series, twenty seven different labyrinth side weir models having triangular plan view that are manufactured from steel were tested in the laboratory flume. A labyrinth weir is an overflow weir that is folded in plan view to provide a longer total effective length for a given overall weir width. To estimate the outflow over a side weir, the discharge coefficient in the side weir equation needs to be determined. A comprehensive laboratory study including 679 tests was conducted to determine the discharge coefficient of the side weirs. It was found that the discharge coefficient of triangular labyrinth side weirs was higher than that of classical side weirs. In addition, reliable equations to calculate the discharge coefficient of side weirs are presented.

[1]  Özgür Kisi,et al.  Predicting discharge capacity of triangular labyrinth side weir located on a straight channel by using an adaptive neuro-fuzzy technique , 2010, Adv. Eng. Softw..

[2]  Alireza Keshavarzi,et al.  A study of spatial variation of discharge coefficient in broad‐crested inclined side weirs , 2009 .

[3]  Santosh K. Pathak,et al.  TRIANGULAR SIDE WEIRS , 1987 .

[4]  Kenneth V. H. Smith,et al.  Closure of "Experimental Investigation of Flow Over Side Weirs" , 1978 .

[5]  D. Manivannan,et al.  Discharge Coefficient of Rectangular Side Weirs , 1994 .

[6]  H. Aǵaçcioǵlu,et al.  Discharge Coefficient of a Triangular Side-Weir Located on a Curved Channel , 2004 .

[7]  G S Coleman,et al.  THE DISCHARGING-CAPACITY OF SIDE WEIRS. (INCLUDES APPENDICES). , 1923 .

[8]  William Frazer THE BEHAVIOR OF SIDE WEIRS IN PRISMATIC RECTANGULAR CHANNELS , 1957 .

[9]  Masoud Ghodsian Supercritical flow over a rectangular side weir , 2003 .

[10]  Ali Uyumaz,et al.  Flow Over Side Weirs in Circular Channels , 1985 .

[11]  W. Hager Lateral Outflow Over Side Weirs , 1987 .

[12]  Özgür Kisi,et al.  Application of two different neural network techniques to lateral outflow over rectangular side weirs located on a straight channel , 2010, Adv. Eng. Softw..

[13]  J. P. Tullis,et al.  Design of Labyrinth Spillways , 1995 .

[14]  Prabhata K. Swamee,et al.  Side-weir analysis using elementary discharge coefficient , 1994 .

[15]  Willi H. Hager Supercritical Flow in Circular‐Shaped Side Weir , 1994 .

[16]  R. W. P. May,et al.  Hydraulic Design of Side Weirs , 2003 .

[17]  Smith,et al.  A THEORETICAL CONSIDERATION OF SIDE WEIRS AS STORMWATER OVERFLOWS. HYDRAULICS PAPER NO 11. SYMPOSIUM OF FOUR PAPERS ON SIDE SPILLWAYS. , 1957 .

[18]  Nihat Kaya,et al.  Discharge Capacity of Labyrinth Side Weir Located on a Straight Channel , 2010 .

[19]  Mauro Fiorentino,et al.  Hydraulic features of supercritical flow along prismatic side weirs , 2001 .

[20]  Hin-Fatt Cheong Discharge Coefficient of Lateral Diversion from Trapezoidal Channel , 1991 .

[21]  Yalçın Yüksel,et al.  SIDE-WEIR FLOW IN CURVED CHANNELS , 1998 .

[22]  Kanakatti Subramanya,et al.  Spatially Varied Flow over Side-Weirs , 1972 .

[23]  T. Nadesamoorthy,et al.  Discussion of Spatially Varied Flow over Side-Weirs by Kanakatti Subramanya and Subhash Chandra Awasthy , 1972 .

[24]  Otto J. Helweg Microcomputer Applications in Water Resources , 1990 .

[25]  V K Colling THE DISCHARGE CAPACITY OF SIDE WEIRS , 1957 .

[26]  Kittur G. Ranga Raju,et al.  Side Weir in Rectangular Channel , 1979 .

[27]  Masoud Ghodsian,et al.  DISCHARGE COEFFICIENT FOR SHARP-CRESTED SIDE WEIR IN SUBCRITICAL FLOW , 1999 .