Intrathoracic Impedance Monitoring in Patients With Heart Failure: Correlation With Fluid Status and Feasibility of Early Warning Preceding Hospitalization

Background—Patients with heart failure are frequently hospitalized for fluid overload. A reliable method for chronic monitoring of fluid status is therefore desirable. We evaluated an implantable system capable of measuring intrathoracic impedance to identify potential fluid overload before heart failure hospitalization and to determine the correlation between intrathoracic impedance and standard measures of fluid status during hospitalization. Methods and Results—Thirty-three patients with NYHA class III and IV heart failure were implanted with a special pacemaker in the left pectoral region and a defibrillation lead in the right ventricle. Intrathoracic impedance was regularly measured and recorded between the lead and the pacemaker case. During hospitalizations, pulmonary capillary wedge pressure and fluid status were monitored. Ten patients were hospitalized for fluid overload 25 times over 20.7±8.4 months. Intrathoracic impedance decreased before each admission by an average of 12.3±5.3% (P<0.001) over an average of 18.3±10.1 days. Impedance reduction began 15.3±10.6 days (P<0.001) before the onset of worsening symptoms. There was an inverse correlation between intrathoracic impedance and pulmonary capillary wedge pressure (r=−0.61, P<0.001) and between intrathoracic impedance and net fluid loss (r=−0.70, P<0.001) during hospitalization. Automated detection of impedance decreases was 76.9% sensitive in detecting hospitalization for fluid overload, with 1.5 false-positive (threshold crossing without hospitalization) detections per patient-year of follow-up. Conclusions—Intrathoracic impedance is inversely correlated with pulmonary capillary wedge pressure and fluid balance and decreased before the onset of patient symptoms and before hospital admission for fluid overload. Regular monitoring of impedance may provide early warning of impending decompensation and diagnostic information for titration of medication.

[1]  T. Yamamoto,et al.  Characteristics of skin admittance for dry electrodes and the measurement of skin moisturisation , 2006, Medical and Biological Engineering and Computing.

[2]  W. Olson,et al.  Feasibility of Using an Implantable System to Measure Thoracic Congestion in an Ambulatory Chronic Heart Failure Canine Model , 2005, Pacing and clinical electrophysiology : PACE.

[3]  W. Abraham,et al.  Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure: Prognostic Value of Heart Rate Variability Measured by an Implanted Cardiac Resynchronization Device , 2004, Circulation.

[4]  D. DeMets,et al.  Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. , 2004, The New England journal of medicine.

[5]  A. Louis,et al.  A systematic review of telemonitoring for the management of heart failure , 2003, European journal of heart failure.

[6]  M. Walsh,et al.  Randomized trial of a daily electronic home monitoring system in patients with advanced heart failure: the Weight Monitoring in Heart Failure (WHARF) trial. , 2003, American heart journal.

[7]  R. Canby,et al.  Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. , 2003, JAMA.

[8]  S. Silver,et al.  Heart Failure , 1937, The New England journal of medicine.

[9]  Milton Packer,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[10]  D. Delurgio,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[11]  Simon Capewell,et al.  The current cost of heart failure to the National Health Service in the UK , 2002, European journal of heart failure.

[12]  J. Oss,et al.  PROPHYLACTIC IMPLANTATION OF A DEFIBRILLATOR IN PATIENTS WITH MYOCARDIAL INFARCTION AND REDUCED EJECTION FRACTION , 2002 .

[13]  E. Antman,et al.  ACC/AHA PRACTICE GUIDELINES ACC/AHA Guidelines for the Evaluation and Management of Chronic Heart Failure in the Adult: Executive Summary , 2002 .

[14]  G Charach,et al.  Transthoracic monitoring of the impedance of the right lung in patients with cardiogenic pulmonary edema , 2001, Critical care medicine.

[15]  B H Brown,et al.  Monitoring patients with left ventricular failure by electrical impedance tomography , 1999, European journal of heart failure.

[16]  G. Huster,et al.  Characterization of the precipitants of hospitalization for heart failure decompensation. , 1998, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[17]  M. Friedman,et al.  Older adults' symptoms and their duration before hospitalization for heart failure. , 1997, Heart & lung : the journal of critical care.

[18]  N. Secher,et al.  Thoracic electrical impedance and fluid balance during aortic surgery , 1995, Acta Anaesthesiologica Scandinavica.

[19]  N. Secher,et al.  Thoracic impedance as an index of body fluid balance during cardiac surgery , 1991, Acta anaesthesiologica Scandinavica.

[20]  C. Saunders The use of transthoracic electrical bioimpedance in assessing thoracic fluid status in emergency department patients. , 1988, The American journal of emergency medicine.

[21]  J N Sahalos,et al.  The electrical impedance of the human thorax as a guide in evaluation of intrathoracic fluid volume. , 1986, Physics in medicine and biology.

[22]  T. Yamamoto,et al.  Electrical properties of the epidermal stratum corneum. , 1973, Medical & biological engineering.

[23]  W. Kubicek,et al.  Transthoracic electric impedance. A clinical guide of pulmonary fluid accumulation in congestive heart failure. , 1975, Minnesota medicine.

[24]  R. Patterson,et al.  The Minnesota impedance cardiograph- theory and applications. , 1974, Biomedical engineering.

[25]  L. Baker,et al.  Noninvasive measurement of intrathoracic fluids. , 1974, Chest.

[26]  D. Aviado Pulmonary Edema Due To Intracranial Lesions , 1974 .

[27]  J M Van de Water,et al.  Monitoring the chest with impedance. , 1973, Chest.

[28]  R. Luepker,et al.  Transthoracic electrical impedance; quantitative evaluation of a non-invasive measure of thoracic fluid volume. , 1973, American Heart Journal.

[29]  THE PARAMETERS OF TRANSTHORACIC ELECTRICAL CONDUCTION * , 1970 .

[30]  B Eiseman,et al.  Transthoracic electrical impedance for the early detection of pulmonary edema. , 1969, Surgery.