In vivo high-speed imaging of individual cells in fast blood flow.

In vivo, label-free, high-speed (up to 10,000 with the potential for 40,000 frames per second), high-resolution (up to 300 nm) real-time continuous imaging with successive framing of circulating individual erythrocytes, leukocytes, and platelets in fast blood flow is developed. This technique, used in an animal model, reveals the extremely high dynamic deformability of erythrocytes in natural flow. Potential applications of this technique are discussed with focus on time-resolved monitoring of the cell deformation dynamics in the native biological environment, which may have diagnostic value for the early diagnosis of diseases.

[1]  Valery V Tuchin,et al.  In vivo photothermal flow cytometry: Imaging and detection of individual cells in blood and lymph flow , 2006, Journal of cellular biochemistry.

[2]  Stefan Schinkinger,et al.  Deformability‐based flow cytometry , 2004, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[3]  V. Tuchin,et al.  In vivo integrated flow image cytometry and lymph/blood vessels dynamic microscopy. , 2005, Journal of biomedical optics.

[4]  Xunbin Wei,et al.  In vivo imaging of specialized bone marrow endothelial microdomains for tumour engraftment , 2005, Nature.

[5]  Gabriel Popescu,et al.  Erythrocyte structure and dynamics quantified by Hilbert phase microscopy. , 2005, Journal of biomedical optics.

[6]  Erik Lindsley,et al.  In vivo cytometry: A spectrum of possibilities , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[7]  R. Skalak,et al.  Deformation of Red Blood Cells in Capillaries , 1969, Science.

[8]  Magalie Faivre,et al.  High-speed microfluidic differential manometer for cellular-scale hydrodynamics. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[9]  H. H. Lipowsky,et al.  Leukocyte margination and deformation in mesenteric venules of rat. , 1989, The American journal of physiology.

[10]  C. Scheinecker Application of in vivo microscopy: evaluating the immune response in living animals , 2005, Arthritis research & therapy.

[11]  Aleksander S Popel,et al.  Effect of erythrocyte aggregation at normal human levels on functional capillary density in rat spinotrapezius muscle. , 2006, American journal of physiology. Heart and circulatory physiology.

[12]  Valery V. Tuchin,et al.  Optical Clearing of Tissues and Blood , 2005 .

[13]  H. H. Lipowsky,et al.  Microvascular Rheology and Hemodynamics , 2005, Microcirculation.

[14]  H. Schmid-schönbein Blood rheology and physiology of microcirculation. , 1981, La Ricerca in clinica e in laboratorio.

[15]  Aleksander S Popel,et al.  Aggregate formation of erythrocytes in postcapillary venules. , 2005, American journal of physiology. Heart and circulatory physiology.

[16]  Valery V Tuchin,et al.  Integrated photothermal flow cytometry in vivo. , 2005, Journal of biomedical optics.

[17]  K. Tsukada,et al.  Optical bioimaging: from living tissue to a single molecule: imaging and functional analysis of blood flow in organic microcirculation. , 2003, Journal of pharmacological sciences.

[18]  Gerard L Coté,et al.  Measuring microlymphatic flow using fast video microscopy. , 2005, Journal of biomedical optics.

[19]  Valery V Tuchin,et al.  Photothermal image flow cytometry in vivo. , 2005, Optics letters.