Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion

Abstract Much of the published works assessing the reliability of smartphone goniometer apps (SG) have poor generalizability since the reliability was assessed in healthy subjects. No research has established the values for standard error of measurement (SEM) or minimal detectable change (MDC) which have greater clinical utility to contextualize the range of motion (ROM) assessed using the SG. This research examined the test‐retest reproducibility, concurrent validity, SEM, and MDC values for the iPhone goniometer app (i‐Goni; June Software Inc., v.1.1, San Francisco, CA) in assessing knee ROM in patients with knee osteoarthritis or those after total knee replacement. A total of 60 participants underwent data collection which included the assessment of active knee ROM using the i‐Goni and the universal goniometer (UG; EZ Read Jamar Goniometer, Patterson Medical, Warrenville, IL), knee muscle strength, and assessment of pain and lower extremity disability using quadruple numeric pain rating scale (Q‐NPRS) and lower extremity functional scale (LEFS), respectively. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of the knee ROM assessed using the i‐Goni and UG. Bland and Altman technique examined the agreement between these knee ROM. The SEM and MDC values were calculated for i‐Goni assessed knee ROM to characterize the error in a single score and the index of true change, respectively. Pearson correlation coefficient examined concurrent relationships between the i‐Goni and other measures. The ICC values for the knee flexion/extension ROM were superior for i‐Goni (0.97/0.94) compared with the UG (0.95/0.87). The SEM values were smaller for i‐Goni assessed knee flexion/extension (2.72/1.18 degrees) compared with UG assessed knee flexion/extension (3.41/1.62 degrees). Similarly, the MDC values were smaller for both these ROM for the i‐Goni (6.3 and 2.72 degrees) suggesting smaller change required to infer true change in knee ROM. The i‐Goni assessed knee ROM showed expected concurrent relationships with UG, knee muscle strength, Q‐NPRS, and the LEFS. In conclusion, the i‐Goni demonstrated superior reproducibility with smaller measurement error compared with UG in assessing knee ROM in the recruited cohort. Future research can expand the inquiry for assessing the reliability of the i‐Goni to other joints.

[1]  L. Brosseau,et al.  Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. , 2001, Archives of physical medicine and rehabilitation.

[2]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[3]  Stephanie Morton,et al.  Reliability and validity of goniometric iPhone applications for the assessment of active shoulder external rotation , 2014, Physiotherapy theory and practice.

[4]  Vero Vanden Abeele,et al.  Increasing the reliability and validity of quantitative laddering data with LadderUX , 2012, CHI Extended Abstracts.

[5]  Susan Gordon,et al.  Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians. , 2014, Manual therapy.

[6]  Mayerson Nh,et al.  Goniometric measurement reliability in physical medicine. , 1984 .

[7]  P. Stratford,et al.  Modelling knee range of motion post arthroplasty: clinical applications. , 2010, Physiotherapy Canada. Physiotherapie Canada.

[8]  S. Summers Evidence-based practice part 2: reliability and validity of selected acute pain instruments. , 2001, Journal of perianesthesia nursing : official journal of the American Society of PeriAnesthesia Nurses.

[9]  Thomas Bandholm,et al.  Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter? , 2010, Physiotherapy research international : the journal for researchers and clinicians in physical therapy.

[10]  N. Mayerson,et al.  Goniometric measurement reliability in physical medicine. , 1984, Archives of physical medicine and rehabilitation.

[11]  M. Jensen,et al.  Increasing the reliability and validity of pain intensity measurement in chronic pain patients , 1993, Pain.

[12]  S. Mehta,et al.  Measurement Properties of the Lower Extremity Functional Scale: A Systematic Review. , 2015, The Journal of orthopaedic and sports physical therapy.

[13]  R. Deyo,et al.  Back pain in primary care. Outcomes at 1 year. , 1993, Spine.

[14]  M. Sumitani,et al.  Novel 3-Dimensional Motion Analysis Method for Measuring the Lumbar Spine Range of Motion: Repeatability and Reliability Compared With an Electrogoniometer , 2013, Spine.

[15]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Elbow and knee measurements. , 1984, Physical therapy.

[16]  D. Altman,et al.  Agreement Between Methods of Measurement with Multiple Observations Per Individual , 2007, Journal of biopharmaceutical statistics.

[17]  B. Jolles,et al.  Reliability of the Knee Smartphone-Application Goniometer in the Acute Orthopedic Setting , 2016, The Journal of Knee Surgery.

[18]  M. Ockendon,et al.  Validation of a Novel Smartphone Accelerometer-Based Knee Goniometer , 2012, The Journal of Knee Surgery.

[19]  J. Jenny,et al.  Measurement of the knee flexion angle with a Smartphone-application is precise and accurate. , 2013, The Journal of arthroplasty.

[20]  S. Rose,et al.  Reliability and validity of goniometric measurements at the knee. , 1987, Physical therapy.

[21]  B. Tiplady,et al.  Validity and sensitivity of visual analogue scales in young and older healthy subjects. , 1998, Age and ageing.

[22]  S L Wolf,et al.  Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. , 1988, Physical therapy.

[23]  Rebecca Sealey,et al.  Concurrent validity and reliability of the Simple Goniometer iPhone app compared with the Universal Goniometer , 2014, Physiotherapy theory and practice.

[24]  L. Brosseau,et al.  Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. , 1997, Physiotherapy research international : the journal for researchers and clinicians in physical therapy.

[25]  Avner Schlessinger,et al.  ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI , 2012 .

[26]  PD Dr. Werner Müller,et al.  The Knee , 1982, Springer Berlin Heidelberg.

[27]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[28]  R. Wellmon,et al.  Validity and Reliability of 2 Goniometric Mobile Apps: Device, Application, and Examiner Factors. , 2016, Journal of sport rehabilitation.

[29]  M J Buxton,et al.  Evaluating patient-based outcome measures for use in clinical trials. , 1998, Health technology assessment.

[30]  Jennifer McGinley,et al.  Test-retest reliability and inter-tester reliability of kinematic data from a three-dimensional gait analysis system. , 2003, Journal of the Japanese Physical Therapy Association = Rigaku ryoho.

[31]  N. Thompson,et al.  The influence of pain on knee motion in patients with osteoarthritis undergoing total knee arthroplasty. , 2009, Orthopedics.

[32]  M M Horger,et al.  The reliability of goniometric measurements of active and passive wrist motions. , 1990, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[33]  M. Jensen,et al.  The use of multiple-item scales for pain intensity measurement in chronic pain patients , 1996, PAIN.

[34]  C. Arnold,et al.  The Reliability and Validity of Handheld Dynamometry for the Measurement of Lower-Extremity Muscle Strength in Older Adults , 2010, Journal of strength and conditioning research.

[35]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[36]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[37]  Geraldo Fabiano de Souza Moraes,et al.  Confiabilidade intra e interexaminadores e erro da medição no uso do goniômetro e inclinômetro digital , 2012 .