Phase-contrast MRI volume flow – a comparison of breath held and navigator based acquisitions

BackgroundMagnetic Resonance Imaging (MRI) 2D phase-contrast flow measurement has been regarded as the gold standard in blood flow measurements and can be performed with free breathing or breath held techniques. We hypothesized that the accuracy of flow measurements obtained with segmented phase-contrast during breath holding, and in particular higher number of k-space segments, would be non-inferior compared to navigator phase-contrast. Volumes obtained from anatomic segmentation of cine MRI and Doppler echocardiography were used for additional reference.MethodsForty patients, five women and 35 men, mean age 65 years (range 53–80), were randomly selected and consented to the study. All underwent EKG-gated cardiac MRI including breath hold cine, navigator based free-breathing phase-contrast MRI and breath hold phase-contrast MRI using k-space segmentation factors 3 and 5, as well as transthoracic echocardiography within 2 days.ResultsIn navigator based free-breathing phase-contrast flow, mean stroke volume and cardiac output were 79.7 ± 17.1 ml and 5071 ± 1192 ml/min, respectively. The duration of the acquisition was 50 ± 6 s. With k-space segmentation factor 3, the corresponding values were 77.7 ml ± 17.5 ml and 4979 ± 1211 ml/min (p = 0.15 vs navigator). The duration of the breath hold was 17 ± 2 s. K-space segmentation factor 5 gave mean stroke volume 77.9 ± 16.4 ml, cardiac output 5142 ± 1197 ml/min (p = 0.33 vs navigator), and breath hold time 11 ± 1 s. Anatomical segmentation of cine gave mean stroke volume and cardiac output 91.2 ± 20.8 ml and 5963 ± 1452 ml/min, respectively. Echocardiography was reliable in 20 of the 40 patients. The mean diameter of the left ventricular outflow tract was 20.7 ± 1.5 mm, stroke volume 78.3 ml ± 15.2 ml and cardiac output 5164 ± 1249 ml/min.ConclusionsIn forty consecutive patients with coronary heart disease, breath holding and segmented k-space sampling techniques for phase-contrast flow produced stroke volumes and cardiac outputs similar to those obtained with free-breathing navigator based phase-contrast MRI, using less time. The values obtained agreed fairly well with Doppler echocardiography while there was a larger difference when compared with anatomical volume determinations using SSFP (steady state free precession) cine MRI.

[1]  R. Mohiaddin,et al.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI , 2005, European Radiology.

[2]  S. Wolff,et al.  Baseline correction of phase contrast images improves quantification of blood flow in the great vessels. , 2007, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[3]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[4]  E. Edelman,et al.  Cardiology is flow. , 2006, Circulation.

[5]  Bernd Hamm,et al.  Head-to-head comparison of left ventricular function assessment with 64-row computed tomography, biplane left cineventriculography, and both 2- and 3-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging as the reference standard. , 2012, Journal of the American College of Cardiology.

[6]  Sebastian Ley,et al.  Accuracy of Right and Left Ventricular Functional Assessment by Short-Axis vs Axial Cine Steady-State Free-Precession Magnetic Resonance Imaging: Intrapatient Correlation with Main Pulmonary Artery and Ascending Aorta Phase-Contrast Flow Measurements , 2013, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[7]  L. Shaw,et al.  Journal of Cardiovascular Magnetic Resonance Clinical Indications for Cardiovascular Magnetic Resonance (cmr): Consensus Panel Report , 2022 .

[8]  Victor Mor-Avi,et al.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. , 2015, European heart journal cardiovascular Imaging.

[9]  Åse A. Johnsson,et al.  Mitral regurgitation quantification by cardiovascular magnetic resonance: a comparison of indirect quantification methods , 2015, The International Journal of Cardiovascular Imaging.

[10]  Roberto Lang,et al.  Discordance between echocardiography and MRI in the assessment of mitral regurgitation severity: a prospective multicenter trial. , 2015, Journal of the American College of Cardiology.

[11]  P. Kilner,et al.  The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mapping , 2009, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[12]  J. Francis,et al.  Operator induced variability in left ventricular measurements with cardiovascular magnetic resonance is improved after training. , 2007, Journal of Cardiovascular Magnetic Resonance.

[13]  Piet Claus,et al.  Multi-centre validation of an automatic algorithm for fast 4D myocardial segmentation in cine CMR datasets. , 2016, European heart journal cardiovascular Imaging.

[14]  David N Firmin,et al.  A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors , 2012, Journal of Cardiovascular Magnetic Resonance.

[15]  A. van Rossum,et al.  Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements , 2010, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[16]  J. Pauly,et al.  One‐shot spatially resolved velocity imaging , 1998, Magnetic resonance in medicine.

[17]  Raad Mohiaddin,et al.  How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping. , 2005, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[18]  B Wranne,et al.  Subaortic flow profiles in aortic valve disease: a two-dimensional color Doppler study. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[19]  Hans-Ulrich Kauczor,et al.  MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers. , 2006, AJR. American journal of roentgenology.

[20]  N J Pelc,et al.  Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.

[21]  Douglas G. Altman,et al.  Practical statistics for medical research , 1990 .

[22]  Scott D Flamm,et al.  Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing , 2013, Journal of Cardiovascular Magnetic Resonance.

[23]  K. Takeda,et al.  Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI , 2001, Magnetic resonance in medicine.

[24]  Alistair A. Young,et al.  Quantification of LV function and mass by cardiovascular magnetic resonance: multi-center variability and consensus contours , 2015, Journal of Cardiovascular Magnetic Resonance.

[25]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[26]  Jan D’hooge,et al.  Determining optimal noninvasive parameters for the prediction of left ventricular remodeling in chronic ischemic patients , 2013, Scandinavian cardiovascular journal : SCJ.