Clinical multiphoton FLIM tomography

This paper gives an overview on current clinical high resolution multiphoton fluorescence lifetime imaging in volunteers and patients. Fluorescence lifetime imaging (FLIM) in Life Sciences was introduced in Jena/Germany in 1988/89 based on a ZEISS confocal picosecond dye laser scanning microscope equipped with a single photon counting unit. The porphyrin distribution in living cells and living tumor-bearing mice was studied with high spatial, temporal, and spectral resolution. Ten years later, time-gated cameras were employed to detect dental caries in volunteers based on one-photon excitation of autofluorescent bacteria with long fluorescence lifetimes. Nowadays, one-photon FLIM based on picosecond VIS laser diodes are used to study ocular diseases in humans. Already one decade ago, first clinical twophoton FLIM images in humans were taken with the certified clinical multiphoton femtosecond laser tomograph DermaInspectTM. Multiphoton tomographs with FLIM modules are now operating in hospitals at Brisbane, Tokyo, Berlin, Paris, London, Modena and other European cities. Multiple FLIM detectors allow spectral FLIM with a temporal resolution down to 20 ps (MCP) / 250 ps (PMT) and a spectral resolution of 10 nm. Major FLIM applications include the detection of intradermal sunscreen and tattoo nanoparticles, the detection of different melanin types, the early diagnosis of dermatitis and malignant melanoma, as well as the measurement of therapeutic effects in pateints suffering from dermatitis. So far, more than 1,000 patients and volunteers have been investigated with the clinical multiphoton FLIM tomographs DermaInspectTM and MPTflexTM.

[1]  Karsten König,et al.  Intravital multiphoton tomography as a novel tool for non-invasive in vivo analysis of human skin affected with atopic dermatitis , 2010, BiOS.

[2]  Iris Riemann,et al.  High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. , 2003, Journal of biomedical optics.

[3]  Karsten König,et al.  Clinical multiphoton tomography , 2008, Journal of biophotonics.

[4]  Karsten König,et al.  Spectral fluorescence lifetime detection and selective melanin imaging by multiphoton laser tomography for melanoma diagnosis , 2009, Experimental dermatology.

[5]  Christopher Dunsby,et al.  A multispectral FLIM tomograph for in-vivo imaging of skin cancer , 2011, BiOS.

[6]  I. Riemann,et al.  Fluorescence lifetime imaging of human skin and hair , 2006, SPIE BiOS.

[7]  Axel Bergmann,et al.  Picosecond fluorescence lifetime microscopy by TCSPC imaging , 2001, SPIE BiOS.

[8]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[9]  P. So,et al.  Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress , 1996, Journal of microscopy.

[10]  Dietrich Schweitzer,et al.  Autofluorescence lifetime measurements in images of the human ocular fundus , 2001, European Conference on Biomedical Optics.

[11]  Karsten König,et al.  Fluorescence lifetime imaging of skin cancer , 2011, BiOS.

[12]  Karsten König,et al.  Multiphoton fluorescence lifetime imaging of 3D‐stem cell spheroids during differentiation , 2011, Microscopy research and technique.

[13]  K. König,et al.  Non-invasive imaging of skin physiology and percutaneous penetration using fluorescence spectral and lifetime imaging with multiphoton and confocal microscopy. , 2011, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[14]  Peter Fischer,et al.  Multiphoton FLIM and spectral imaging of cells and tissues , 2004, SPIE BiOS.

[15]  Peter Fischer,et al.  Optical tomography of human skin with subcellular spatial and picosecond time resolution using intense near infrared femtosecond laser pulses , 2002, SPIE BiOS.

[16]  Thomas Zimmer,et al.  FRET measurements by TCSPC laser scanning microscopy , 2001, European Conference on Biomedical Optics.