Analysis of physiological impact while reading stereoscopic radiographs

A stereoscopic viewing technology is expected to improve diagnostic performance in terms of reading efficiency by adding one more dimension to the conventional 2D images. Although a stereoscopic technology has been applied to many different field including TV, movies and medical applications, physiological fatigue through reading stereoscopic radiographs has been concerned although no established physiological fatigue data have been provided. In this study, we measured the α-amylase concentration in saliva, heart rates and normalized tissue hemoglobin index (nTHI) in blood of frontal area to estimate physiological fatigue through reading both stereoscopic radiographs and the conventional 2D radiographs. In addition, subjective assessments were also performed. As a result, the pupil contraction occurred just after the reading of the stereoscopic images, but the subjective assessments regarding visual fatigue were nearly identical for the reading the conventional 2D and stereoscopic radiographs. The α-amylase concentration and the nTHI continued to decline while examinees read both 2D and stereoscopic images, which reflected the result of subjective assessment that almost half of the examinees reported to feel sleepy after reading. The subjective assessments regarding brain fatigue showed that there were little differences between 2D and stereoscopic reading. In summary, this study shows that the physiological fatigue caused by stereoscopic reading is equivalent to the conventional 2D reading including ocular fatigue and burden imposed on brain.

[1]  Yuzo Hirayama,et al.  Evaluation of the influence on the human body of the autostereoscopic display based on the integral imaging method , 2008, Electronic Imaging.

[2]  Masaki Emoto,et al.  Two factors in visual fatigue caused by stereoscopic HDTV images , 2004 .

[3]  James S. Wolffsohn,et al.  Target spatial frequency determines the response to conflicting defocus- and convergence-driven accommodative stimuli , 2006, Vision Research.

[4]  Yoshitaka Yanagihara,et al.  A Study of Vergence Effect on Binocular-Stereo-Vision System , 2001 .

[5]  S Ishikawa,et al.  A quasistatic study of pupil and accommodation after‐effects following near vision , 1989, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[6]  Ehsan Samei,et al.  Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection. , 2011, Medical physics.

[7]  Roberta L. Moldow,et al.  Developing psychophysiological profiles for monitoring stress , 2006, SPIE Defense + Commercial Sensing.

[8]  Masayuki Nakajima,et al.  Study of asthenopia caused by the viewing of stereoscopic images: measurement by MEG and other devices , 2006, Electronic Imaging.

[9]  Takashi Maeda,et al.  [Evaluation of image quality using the normalized-rank approach for primary class liquid-crystal display (LCD) monitors with different colors and resolution]. , 2010, Nihon Hoshasen Gijutsu Gakkai zasshi.

[10]  Tohru Yagi,et al.  Study on Physiological Indexes during Mental Focus Task , 2009 .

[11]  Hiroki Takada,et al.  Effect of an Eyesight Recovering Stereoscopic Movie System on Visual Acuity and Asthenopia , 2009, HCI.

[12]  Masaki Emoto,et al.  Visual comfort/discomfort and visual fatigue caused by stereoscopic HDTV viewing , 2004, IS&T/SPIE Electronic Imaging.

[13]  Carl J. D'Orsi,et al.  Stereoscopic Digital Mammography: Improved Accuracy of Lesion Detection in Breast Cancer Screening , 2008, Digital Mammography / IWDM.

[14]  Kevin J. MacKenzie,et al.  Eliminating accommodation-convergence conflicts in stereoscopic displays: Can multiple-focal-plane displays elicit continuous and consistent vergence and accommodation responses? , 2010, Electronic Imaging.

[15]  Zygmunt Pizlo,et al.  Preclinical ROC studies of digital stereomammography , 1995, IEEE Trans. Medical Imaging.

[16]  Michael Cik,et al.  Feasibility of testing three salivary stress biomarkers in relation to naturalistic traffic noise exposure. , 2010, International journal of hygiene and environmental health.

[17]  Hiroyuki Nagatani Application of integral imaging autostereoscopic display to medical training equipment , 2010, Electronic Imaging.

[18]  Takashi Shibata,et al.  Development and evaluation of amusement machine using autostereoscopic 3D display , 2004, IS&T/SPIE Electronic Imaging.