Doubly Fed Induction Generator Wind Turbine Systems Subject to Recurring Symmetrical Grid Faults

New grid codes demand the wind turbine systems to ride through recurring grid faults. In this paper, the performance of the doubly Ffed induction generator (DFIG) wind turbine system under recurring symmetrical grid faults is analyzed. The mathematical model of the DFIG under recurring symmetrical grid faults is established. The analysis is based on the DFIG wind turbine system with the typical low-voltage ride-through strategy-with rotor-side crowbar. The stator natural flux produced by the voltage recovery after the first grid fault may be superposed on the stator natural flux produced by the second grid fault, so that the transient rotor and stator current and torque fluctuations under the second grid fault may be influenced by the characteristic of the first grid fault, including the voltage dips level and the grid fault angle, as well as the duration between two faults. The mathematical model of the DFIG under recurring grid faults is verified by simulations on a 1.5-MW DFIG wind turbine system model and experiments on a 30-kW reduced scale DFIG test system.

[1]  S. M. Islam,et al.  Impacts of Symmetrical and Asymmetrical Voltage Sags on DFIG-Based Wind Turbines Considering Phase-Angle Jump, Voltage Recovery, and Sag Parameters , 2011, IEEE Transactions on Power Electronics.

[2]  S. M. Islam,et al.  Transient Control of DFIG-Based Wind Power Plants in Compliance With the Australian Grid Code , 2012, IEEE Transactions on Power Electronics.

[3]  Zhe Zhang,et al.  Study of Fault Current Characteristics of the DFIG Considering Dynamic Response of the RSC , 2014, IEEE Transactions on Energy Conversion.

[4]  Dehong Xu,et al.  Doubly fed induction generator based wind turbine systems subject to recurring grid faults , 2014, 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014.

[5]  Ehab F. El-Saadany,et al.  An improved fault ride-through strategy for doubly fed induction generator-based wind turbines , 2008 .

[6]  M. H. J. Bollen Voltage Recovery after Unbalanced and Balanced Voltage Dip in Three-Phase Systems , 2002, IEEE Power Engineering Review.

[7]  David J. Atkinson,et al.  Evaluation of the Performance of a DC-Link Brake Chopper as a DFIG Low-Voltage Fault-Ride-Through Device , 2013, IEEE Transactions on Energy Conversion.

[8]  J. Pedra,et al.  Doubly Fed Induction Generator Subject to Symmetrical Voltage Sags , 2011, IEEE Transactions on Energy Conversion.

[9]  Dehong Xu,et al.  Comparison of control strategies for Doubly fed induction generator under recurring grid faults , 2014, 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014.

[10]  Geng Yang,et al.  Analysis of the control limit for rotor-side converter of doubly fed induction generator-based wind energy conversion system under various voltage dips , 2013 .

[11]  Gonzalo Abad,et al.  Single-Phase DC Crowbar Topologies for Low Voltage Ride Through Fulfillment of High-Power Doubly Fed Induction Generator-Based Wind Turbines , 2013, IEEE Transactions on Energy Conversion.

[12]  Zhe Chen,et al.  Enhanced Control of a DFIG-Based Wind-Power Generation System With Series Grid-Side Converter Under Unbalanced Grid Voltage Conditions , 2013, IEEE Transactions on Power Electronics.

[13]  Wei Qiao,et al.  Feed-Forward Transient Current Control for Low-Voltage Ride-Through Enhancement of DFIG Wind Turbines , 2010, IEEE Transactions on Energy Conversion.

[14]  Adeola Balogun,et al.  Decoupled Direct Control of Natural and Power Variables of Doubly Fed Induction Generator for Extended Wind Speed Range Using Feedback Linearization , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[15]  Yong Kang,et al.  An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults , 2011, IEEE Transactions on Power Electronics.

[16]  G Pannell,et al.  Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind Turbine , 2010, IEEE Transactions on Energy Conversion.

[17]  Wilfried Hofmann,et al.  Modeling and Ride-Through Control of Doubly Fed Induction Generators During Symmetrical Voltage Sags , 2011, IEEE Transactions on Energy Conversion.

[18]  Luis Marroyo,et al.  Doubly Fed Induction Machine : Modeling and Control for Wind Energy Generation , 2011 .

[19]  Zhe Chen,et al.  A Review of the State of the Art of Power Electronics for Wind Turbines , 2009, IEEE Transactions on Power Electronics.

[20]  Yongchang Zhang,et al.  Predictive Direct Virtual Torque and Power Control of Doubly Fed Induction Generators for Fast and Smooth Grid Synchronization and Flexible Power Regulation , 2013, IEEE Transactions on Power Electronics.

[21]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[22]  F. Blaabjerg,et al.  Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults , 2010, IEEE Transactions on Power Electronics.

[23]  A. Nasiri,et al.  A Dynamic LVRT Solution for Doubly Fed Induction Generators , 2010, IEEE Transactions on Power Electronics.

[24]  Heng Nian,et al.  Direct Power Control of Doubly Fed Induction Generator Under Distorted Grid Voltage , 2014, IEEE Transactions on Power Electronics.

[25]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[26]  Christos Mademlis,et al.  Optimal Efficiency Control Strategy in Wind Energy Conversion System With Induction Generator , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[27]  J. Morren,et al.  Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator , 2007, IEEE Transactions on Energy Conversion.

[28]  M. Liserre,et al.  Power electronics converters for wind turbine systems , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[29]  He Yikang,et al.  Control strategy of an active crowbar for DFIG based wind turbine under grid voltage dips , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[30]  Xi Xu,et al.  Evaluation of the Performance of BTFCLs for Enhancing LVRT Capability of DFIG , 2015, IEEE Transactions on Power Electronics.

[31]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[32]  Geng Yang,et al.  An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECS , 2013, IEEE Transactions on Industrial Electronics.

[33]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .