Requirements for oversized holes for reusable steel-concrete composite floor systems

The design of sustainable structures is increasingly gaining attention in the construction sector as a societal and technological challenge. Demountability and reuse of structures contributes to the reduction of the environmental impact of the built environment. Welded headed studs used in traditional steel-concrete composite floor systems need to be replaced by demountable shear connectors to enable the transition of the construction sector to a circular business model. The demountable shear connectors are embedded in large prefabricated concrete floor elements and connected to steel beams by bolts. The holes in the beam flange are oversized to account for geometrical and dimensional deviations of all members and to facilitate rapid execution and easy demounting. The goal of this paper is to present a methodology that quantifies the required nominal hole clearance for reusable composite floor systems. Statistical characteristics of dimensional and geometrical deviations serve as input for Monte-Carlo simulations. The aggregated results of the Monte Carlo simulations are used to determine the required nominal hole clearance for a specified probability of successful installation of the demountable shear connectors. The proposed methodology is applied to the composite floor system of a demountable and reusable car park building. The contradicting requirement of oversized holes and composite interaction is solved by injecting the hole clearance with a (steel-reinforced) epoxy resin. The bearing resistance of the (steel-reinforced) epoxy resin is addressed based on preliminary results of creep experiments on resin-injected bolted connections.

[1]  Buick Davison,et al.  Design for deconstruction and material reuse , 2011 .

[2]  Peter F. Dux,et al.  INELASTIC BEAM BUCKLING EXPERIMENTS , 1983 .

[3]  Milan Veljkovic,et al.  Non-linear hybrid homogenization method for steel-reinforced resin , 2018, Construction and Building Materials.

[4]  M. P. Nijgh,et al.  New Materials for Injected Bolted Connections: A Feasibility Study for Demountable Connections , 2017 .

[5]  Ulf Arne Girhammar,et al.  A simplified analysis method for composite beams with interlayer slip , 2009 .

[6]  Andrei Gîrbacea Assessment of demountable steel-concrete composite flooring systems , 2018 .

[7]  D. J. Laurie Kennedy,et al.  Distortional buckling of steel beams , 1993 .

[8]  A.A.J.F. Van den Dobbelsteen,et al.  The Sustainable Office. An exploration of the potential for factor 20 environmental improvement of office accommodation , 2004 .

[9]  Milan Veljkovic,et al.  FE validation of push‐out tests , 2017 .

[10]  Milan Veljkovic,et al.  Computational homogenization simulation on steel reinforced resin used in the injected bolted connections , 2019, Composite Structures.

[11]  Luís Simões da Silva,et al.  Design of Steel Structures: Eurocode 3: Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings , 2010 .

[12]  Milan Veljkovic,et al.  Elastic behaviour of a tapered steel-concrete composite beam optimized for reuse , 2019, Engineering Structures.

[13]  Milan Veljkovic,et al.  Push-out tests on demountable shear connectors of steel-concrete composite structures , 2019, Structures.

[14]  Theodore L. Karavasilis,et al.  Removable shear connector for steel-concrete composite bridges , 2018 .

[15]  Shao-Fei Jiang,et al.  Effect of Shear Connector Layout on the Behavior of Steel-Concrete Composite Beams with Interface Slip , 2019, Applied Sciences.

[16]  Zdeněk Kala Sensitivity analysis of steel plane frames with initial imperfections , 2011 .