Gaseous microemboli and the influence of microporous membrane oxygenators.

Gaseous microemboli (GME) are still an unsolved problem of extracorporeal circuits. They are associated with organ injury during cardiopulmonary bypass. Microbubbles of different sizes and number are generated in the blood as the result of different components of the extracorporeal circuit as well as surgical maneuvers. The aim of our study was to observe the behavior of microporous membrane oxygenators to GME in the daily use and in an in vitro model. For the detection of microbubbles, we used a two-channel ultrasonic bubble counter based on 2-MHz Doppler-System with special ultrasound probes. The amount and size of GME were monitored before and after membrane. In 28 scheduled cases with 3 different oxygenators and variability of surgical procedures, we observed the bubble activity in the extracorporeal circuit. In addition, we used an in-vitro model to study the ability of six different oxygenators by removing air in various tests. The oxygenators tested were manufactured with different membrane technologies. The results of our investigations showed varying membrane design lead to a partial removal of GME as well as a change in size and numbers of microbubbles.

[1]  J. Sistino,et al.  The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli. , 2004, The journal of extra-corporeal technology.

[2]  Bruce D Butler,et al.  Bubbles and bypass: an update , 2004, Perfusion.

[3]  H. Tiedtke,et al.  Improved methods for measurement of gaseous microbubbles during extracorporeal circulation , 2002, Perfusion.

[4]  D. Stump,et al.  How effective are cardiopulmonary bypass circuits at removing gaseous microemboli? , 2002, The journal of extra-corporeal technology.

[5]  T. Willcox,et al.  Vacuum-assisted venous drainage: to air or not to air, that is the question. Has the bubble burst? , 2002, The journal of extra-corporeal technology.

[6]  S. Mitchell,et al.  The pathophysiology of cerebral arterial gas embolism. , 2002, The journal of extra-corporeal technology.

[7]  C. Peniston,et al.  Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions. , 2001, The Journal of thoracic and cardiovascular surgery.

[8]  M. Borger,et al.  Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions. , 1999, The Annals of thoracic surgery.

[9]  U. Cobet,et al.  Detection of micro bubbles in the extracorporeal circulation , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[10]  P. Beckley,et al.  A comparison of gaseous emboli release in five membrane oxygenators , 1997, Perfusion.

[11]  B. Troost,et al.  Brain embolic phenomena associated with cardiopulmonary bypass , 1993, Journal of the Neurological Sciences.

[12]  R. Clayton,et al.  Clinical comparison of two devices for detection of microemboli during cardiopulmonary bypass. , 1990, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[13]  C. Blauth,et al.  Demonstration of cerebral microemboli occurring during coronary artery bypass graft surgery using fluorescein angiography. , 1990, The Journal of audiovisual media in medicine.

[14]  J. Hammon,et al.  Cerebral emboli and cognitive outcome after cardiac surgery. , 1996, Journal of cardiothoracic and vascular anesthesia.