Macular ganglion cell imaging study: glaucoma diagnostic accuracy of spectral-domain optical coherence tomography.

PURPOSE We evaluated the diagnostic accuracy of macular ganglion cell-inner plexiform layer (GCIPL) measurements using a high-definition optical coherence tomography (Cirrus HD-OCT) ganglion cell analysis algorithm for detecting early and moderate-to-severe glaucoma. METHODS Totals of 119 normal subjects and 306 glaucoma patients (164 patients with early glaucoma and 142 with moderate-to-severe glaucoma) were enrolled from the Macular Ganglion Cell Imaging Study. Macular GCIPL, peripapillary retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured in each subject. Areas under the receiver operating characteristic curves (AUROCs) were calculated and compared. Based on the internal normative database, the sensitivity and specificity for detecting early and moderate-to-severe glaucoma were calculated. RESULTS There was no statistically significant difference between the AUROCs for the best OCT parameters. For detecting early glaucoma, the sensitivity of the Cirrus GCIPL parameters ranged from 26.8% to 73.2% and that of the Cirrus RNFL parameters ranged from 6.1% to 61.6%. For the early glaucoma group, the best parameter from the GCIPL generally had a higher sensitivity than those of the RNFL and ONH parameters with comparable specificity (P < 0.05, McNemar's test). CONCLUSIONS There were no significant differences between the AUROCs for Cirrus GCIPL, RNFL, and ONH parameters, indicating that these maps have similar diagnostic potentials for glaucoma. The minimum GCIPL showed better glaucoma diagnostic performance than the other parameters at comparable specificities. However, other GCIPL parameters showed performances comparable to those of the RNFL parameters.

[1]  Masanori Hangai,et al.  A novel method to detect local ganglion cell loss in early glaucoma using spectral-domain optical coherence tomography. , 2012, Investigative ophthalmology & visual science.

[2]  Jean-Claude Mwanza,et al.  Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness: comparison with nerve fiber layer and optic nerve head. , 2012, Ophthalmology.

[3]  Kiyoshi Tanaka,et al.  A New Color Visual Function Test to Evaluate the Aging Changes in Normal Eyes , 2012 .

[4]  Youngrok Lee,et al.  Macular and retinal nerve fiber layer thickness: which is more helpful in the diagnosis of glaucoma? , 2011, Investigative ophthalmology & visual science.

[5]  G. Wollstein,et al.  Profile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[6]  W. Feuer,et al.  Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. , 2011, Investigative ophthalmology & visual science.

[7]  M. Hangai,et al.  Detection of localized retinal nerve fiber layer defects in glaucoma using enhanced spectral-domain optical coherence tomography. , 2011, Ophthalmology.

[8]  M. Hangai,et al.  Three-dimensional imaging of macular inner structures in glaucoma by using spectral-domain optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[9]  I. Schmidtmann,et al.  Diagnostic ability of retinal ganglion cell complex, retinal nerve fiber layer, and optic nerve head measurements by Fourier-domain optical coherence tomography , 2011, Graefe's Archive for Clinical and Experimental Ophthalmology.

[10]  Eun Suk Lee,et al.  Structure-function relationship and diagnostic value of macular ganglion cell complex measurement using Fourier-domain OCT in glaucoma. , 2010, Investigative ophthalmology & visual science.

[11]  Boris Hermann,et al.  Robust segmentation of intraretinal layers in the normal human fovea using a novel statistical model based on texture and shape analysis. , 2010, Optics express.

[12]  Alexander Wong,et al.  Intra-retinal layer segmentation in optical coherence tomography images. , 2009, Optics express.

[13]  Delia Cabrera DeBuc,et al.  Reliability and reproducibility of macular segmentation using a custom-built optical coherence tomography retinal image analysis software. , 2009, Journal of biomedical optics.

[14]  Joel S Schuman,et al.  Combining nerve fiber layer parameters to optimize glaucoma diagnosis with optical coherence tomography. , 2008, Ophthalmology.

[15]  Xiaodong Wu,et al.  Intraretinal Layer Segmentation of Macular Optical Coherence Tomography Images Using Optimal 3-D Graph Search , 2008, IEEE Transactions on Medical Imaging.

[16]  Dirk J. Faber,et al.  Recent developments in optical coherence tomography for imaging the retina , 2007, Progress in Retinal and Eye Research.

[17]  Barry Cense,et al.  Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging. , 2005, Archives of ophthalmology.

[18]  U. Schmidt-Erfurth,et al.  Three-dimensional ultrahigh-resolution optical coherence tomography of macular diseases. , 2005, Investigative ophthalmology & visual science.

[19]  Hiroshi Ishikawa,et al.  Macular segmentation with optical coherence tomography. , 2005, Investigative ophthalmology & visual science.

[20]  R S Harwerth,et al.  Ganglion cell losses underlying visual field defects from experimental glaucoma. , 1999, Investigative ophthalmology & visual science.

[21]  Douglas R. Anderson,et al.  Clinical Decisions In Glaucoma , 1993 .

[22]  C. Curcio,et al.  Topography of ganglion cells in human retina , 1990, The Journal of comparative neurology.

[23]  E. DeLong,et al.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. , 1988, Biometrics.

[24]  G. Holló,et al.  Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma , 2011, Eye.

[25]  中谷 雄介 Evaluation of macular thickness and peripapillary retinal nerve fiber layer thickness for detection of early glaucoma using spectral domain optical coherence tomography , 2010 .

[26]  J. D. Cascajosa,et al.  Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography , 2010 .

[27]  J. Katz,et al.  Sensitivity and specificity of the StratusOCT for perimetric glaucoma. , 2005, Ophthalmology.

[28]  A. Sommer,et al.  An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. , 1992, Ophthalmology.

[29]  A. Sommer,et al.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. , 1991, Archives of ophthalmology.