Failure analysis of tendon breakout on bottom slab of a pre-stressed concrete box gird bridge during construction
暂无分享,去创建一个
Abstract There were several tendons breakout on bottom slabs happening during construction stage of continuous pre-stressed concrete bridges in recent years in China. The paper studies one case based on numerical simulation that happened on a 47 + 75 + 47 m continuous pre-stressed concrete rigidframe bridge. In this paper, both linear elastic and nonlinear inelastic analysis are developed, concrete and reinforcements stress levels before and after pre-stressed tendons stressed are compared, and the path of crack appearance are revealed by calculation. The effects of the incorrect arrangement of reinforcement during construction are also analyzed, which is proved not to be the leading reason of the failure. The outcomes of the finite element analysis indicate that oversize of the longitudinal prestressed tendons and unreasonable sizes of the bottom slab are the main reasons of the failure. Some advices to avoid similar accident are given for future design.
[1] Nigel R Hewson,et al. Prestressed concrete bridges : design and construction , 2003 .
[2] Bao Li-xin. Approach to Crack Problems of Bottom Plate of Continuous Rigid Frame Bridges , 2004 .
[3] Li Chao-yang,et al. Analysis of Accident of Bursting Crack in Bottom Slab of a Continuous Rigid-Frame Bridge , 2006 .
[4] Gregor P. Wollmann,et al. Steel Girder Design per AASHTO LRFD Specifications (Part 1) , 2004 .