Landsat-8 Thermal Infrared Sensor (TIRS) Vicarious Radiometric Calibration

Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 μm (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board Landsat-8. The TIRS instrument has an internal calibration system consisting of a variable temperature blackbody and a special viewport with which it can see deep space; a two point calibration can be performed twice an orbit. Immediately after launch, a rigorous vicarious calibration program was started to validate the absolute calibration of the system. The two vicarious calibration teams, NASA/Jet Propulsion Laboratory (JPL) and the Rochester Institute of Technology (RIT), both make use of buoys deployed on large water bodies as the primary monitoring technique. RIT took advantage of cross-calibration opportunity soon after launch when Landsat-8 and Landsat-7 were imaging the same targets within a few minutes of each other to perform a validation of the absolute calibration. Terra MODIS is also being used for regular monitoring of the TIRS absolute calibration. The buoy initial results showed a large error in both bands, 0.29 and 0.51 W/m2·sr·μm or −2.1 K and −4.4 K at 300 K in Band 10 and 11 respectively, where TIRS data was too hot. A calibration update was recommended for both bands to correct for a bias error and was implemented on 3 February 2014 in the USGS/EROS processing system, but the residual variability is still larger than desired for both bands (0.12 and 0.2 W/m2·sr·μm or 0.87 and 1.67 K at 300 K). Additional work has uncovered the source of the calibration error: out-of-field stray light. While analysis continues to characterize the stray light contribution, the vicarious calibration work proceeds. The additional data have not changed the statistical assessment but indicate that the correction (particularly in band 11) is probably only valid for a subset of data. While the stray light effect is small enough in Band 10 to make the data useful across a wide array of applications, the effect in Band 11 is larger and the vicarious results suggest that Band 11 data should not be used where absolute calibration is required.

[1]  Edward J. Knight,et al.  Landsat-8 Operational Land Imager Design, Characterization and Performance , 2014, Remote. Sens..

[2]  Gyanesh Chander,et al.  In-flight validation and recovery of water surface temperature with Landsat-5 thermal infrared data using an automated high-altitude lake validation site at Lake Tahoe , 2004, IEEE Transactions on Geoscience and Remote Sensing.

[3]  Julia A. Barsi,et al.  Calibration of Landsat thermal data and application to water resource studies , 2001 .

[4]  Simon J. Hook,et al.  In-flight validation of mid- and thermal infrared data from the Multispectral Thermal Imager (MTI) using an automated high-altitude validation site at Lake Tahoe CA/NV, USA , 2005, IEEE Transactions on Geoscience and Remote Sensing.

[5]  Matthew Montanaro,et al.  Stray Light Artifacts in Imagery from the Landsat 8 Thermal Infrared Sensor , 2014, Remote. Sens..

[6]  Kenton Lee,et al.  The Spectral Response of the Landsat-8 Operational Land Imager , 2014, Remote. Sens..

[7]  Julia A. Barsi,et al.  Thermal infrared radiometric calibration of the entire Landsat 4, 5, and 7 archive (1982–2010) , 2012 .

[8]  Obi Reddy P. Gangalakunta,et al.  Global irrigated area map (GIAM), derived from remote sensing, for the end of the last millennium , 2009 .

[9]  Eva Rubio,et al.  Thermal band selection for the PRISM instrument: 3. Optimal band configurations , 1998 .

[10]  Matthew Montanaro,et al.  Radiometric Calibration Methodology of the Landsat 8 Thermal Infrared Sensor , 2014, Remote. Sens..

[11]  Matthew Montanaro,et al.  On-Orbit Radiometric Performance of the Landsat 8 Thermal Infrared Sensor , 2014, Remote. Sens..

[12]  Lawrence Ong,et al.  Landsat-8 Operational Land Imager Radiometric Calibration and Stability , 2014, Remote. Sens..

[13]  Jan Kleissl,et al.  From High Overhead: ET Measurement via Remote Sensing , 2008 .

[14]  Julia A. Barsi,et al.  Calibration of Landsat 5 thermal infrared channel: updated calibration history and assessment of the errors associated with the methodology , 2010 .

[15]  Simon J. Hook,et al.  Measuring surface currents in lakes with high spatial resolution thermal infrared imagery , 2005 .

[16]  Gail P. Anderson,et al.  MODTRAN4 radiative transfer modeling for atmospheric correction , 1999, Optics & Photonics.

[17]  Matthew Montanaro,et al.  The Thermal Infrared Sensor (TIRS) on Landsat 8: Design Overview and Pre-Launch Characterization , 2015, Remote. Sens..

[18]  Simon J. Hook,et al.  Absolute Radiometric In-Flight Validation of Mid Infrared and Thermal Infrared Data From ASTER and MODIS on the Terra Spacecraft Using the Lake Tahoe, CA/NV, USA, Automated Validation Site , 2007, IEEE Transactions on Geoscience and Remote Sensing.

[19]  Simon J. Hook,et al.  Retrieval of Lake Bulk and Skin Temperatures Using Along-Track Scanning Radiometer ( ATSR-2 ) Data : A Case Study Using Lake Tahoe , 2002 .