Capillary scale monolithic trap column for desalting and preconcentration of peptides and proteins in one- and two-dimensional separations.

Monolithic columns based on poly-(styrene-divinylbenzene) (PS-DVB) were utilized both for preconcentration (in 10 mm x 0.20 mm I.D. format) and analytical separation (in 60 mm x 0.20 and 0.10 mm I.D. format) of peptides and proteins in column switching micro-scale high-performance liquid chromatography. A special holder for short monolithic preconcentration columns was designed and pressure durability tests approved long-term stability up to 400 bar. An 11-20% decrease in the average peak widths of nine peptides was obtained upon combining a preconcentration column with an analytical column as compared with a setup using an analytical column only. Trapping efficiency, especially for small and hydrophilic peptides, was optimized by using 0.10% heptafluorobutyric acid instead of 0.050% trifluoroacetic acid as solvent additive during sample loading. Using a 10 mm x 0.20 mm I.D. preconcentration column, loadabilities between 0.5 and 1.6 microg were determined by frontal analysis of proteins and bioactive peptides, respectively. A 100-fold concentration followed by direct on-line intact mass determination is demonstrated for diluted (3 micromolL(-1)) protein solutions. The applicability of the monolithic preconcentration column for multidimensional chromatography was tested by off-line two-dimensional separation, combining strong cation-exchange chromatography and ion-pair reversed-phase chromatography. Peptide identification data from digested protein mixtures demonstrated reproducibilities of 46-75% in triplicate analyses, and confident peptide identifications of low abundant peptides even in the presence of a 650-fold molar excess of high abundant peptides.

[1]  Nikola Tolić,et al.  Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-nanoESI MS and MS/MS. , 2004, Analytical chemistry.

[2]  J. Fréchet,et al.  Rapid reversed-phase separation of proteins and peptides using optimized 'moulded' monolithic poly(styrene-co-divinylbenzene) columns. , 1999, Journal of chromatography. A.

[3]  C. Cramers,et al.  Microcolumn liquid chromatography: Instrumentation, detection and applications , 1997 .

[4]  S. Patterson,et al.  Automated LC-LC-MS-MS platform using binary ion-exchange and gradient reversed-phase chromatography for improved proteomic analyses. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[5]  R. Anderegg,et al.  Comprehensive on-line LC/LC/MS of proteins. , 1997, Analytical chemistry.

[6]  I. Gusev,et al.  Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography. , 1999, Journal of chromatography. A.

[7]  J. Veuthey,et al.  Column-Switching Procedures for the Fast Analysis of Drugs in Biologic Samples , 2004, Therapeutic drug monitoring.

[8]  J. Fréchet,et al.  Macroporous polymeric stationary-phase rod as continuous separation medium for reversed-phase chromatography. , 1993, Analytical chemistry.

[9]  C. Huber,et al.  Characterization of some physical and chromatographic properties of monolithic poly(styrene-co-divinylbenzene) columns. , 2004, Journal of chromatography. A.

[10]  Guanghui Wang,et al.  Global protein identification and quantification technology using two-dimensional liquid chromatography nanospray mass spectrometry. , 2003, Analytical chemistry.

[11]  P. Oefner,et al.  Mutation detection by capillary denaturing high-performance liquid chromatography using monolithic columns. , 2001, Journal of biochemical and biophysical methods.

[12]  C. Huber,et al.  Multidimensional proteomic analysis of photosynthetic membrane proteins by liquid extraction‐ultracentrifugation‐liquid chromatography‐mass spectrometry , 2004, Proteomics.

[13]  J. Fréchet,et al.  Reversed-phase chromatography of small molecules and peptides on a continuous rod of macroporous poly(styrene-co-divinylbenzene). , 1994, Journal of chromatography. A.

[14]  Timothy J. Mitchison,et al.  Comparison of three directly coupled HPLC MS/MS strategies for identification of proteins from complex mixtures: single-dimension LC-MS/MS, 2-phase MudPIT, and 3-phase MudPIT , 2002 .

[15]  P. Højrup,et al.  Rapid identification of proteins by peptide-mass fingerprinting , 1993, Current Biology.

[16]  K. Mechtler,et al.  Automated, on‐line two‐dimensional nano liquid chromatography tandem mass spectrometry for rapid analysis of complex protein digests , 2004, Proteomics.

[17]  J. Yates,et al.  An automated multidimensional protein identification technology for shotgun proteomics. , 2001, Analytical chemistry.

[18]  C. Rivasseau,et al.  On‐line solid‐phase extraction in microcolumn‐ liquid chromatography coupled to UV or MS detection: Application to the analysis of cyanobacterial toxins , 2000 .

[19]  E. Schlimme,et al.  Synthesis and application of a boronic acid-substituted silica for high-performance liquid affinity chromatography , 1983 .

[20]  R. W. Frei,et al.  Selective Sample Handling and Detection in High-Performance Liquid Chromatography , 1988 .

[21]  Ronald J Moore,et al.  High-efficiency on-line solid-phase extraction coupling to 15-150-microm-i.d. column liquid chromatography for proteomic analysis. , 2003, Analytical chemistry.

[22]  C. Huber,et al.  High-performance liquid chromatography-electrospray ionization mass spectrometry of single- and double-stranded nucleic acids using monolithic capillary columns. , 2000, Analytical chemistry.

[23]  J. Henion,et al.  Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry. , 2002, Analytical chemistry.

[24]  J. Henion,et al.  Peer Reviewed: Sample Preparation for LC/MS/MS: Analyzing Biological and Environmental Samples , 1998 .

[25]  J. Veuthey,et al.  Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[26]  Li Zang,et al.  Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-microm-i.d. polystyrene-divinylbenzene monolithic capillary columns. , 2003, Analytical chemistry.

[27]  C. Huber,et al.  Capillary monoliths for the analysis of nucleic acids by high-performance liquid chromatography–electrospray ionization mass spectrometry , 2002 .

[28]  C. Huber,et al.  Operational variables in high-performance liquid chromatography-electrospray ionization mass spectrometry of peptides and proteins using poly(styrene-divinylbenzene) monoliths. , 2004, Journal of chromatography. A.

[29]  Arndt Asperger,et al.  Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation. , 2002, Journal of chromatography. A.

[30]  C. Huber,et al.  High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies. , 2001, Analytical chemistry.

[31]  D. N. Perkins,et al.  Probability‐based protein identification by searching sequence databases using mass spectrometry data , 1999, Electrophoresis.