Minimisation of the wall shear stress gradients in bypass grafts anastomoses using meshless CFD and genetic algorithms optimisation

The wall shear stress (WSS) spatial and temporal gradients are two hemodynamics parameters correlated with endothelial damage. Those two gradients become well pronounced in a bypass graft anastomosis geometry where the blood flow patterns are quite disturbed. The WSS gradient minimisation on the host artery floor can be achieved by optimising the anastomosis shape and hence may lead to an improved long-term post-surgical performance of the graft. The anastomosis shape optimisation can be executed via an integrated computational tool comprised of a meshless computational fluid dynamics (CFD) solver and a genetic algorithm (GA) shape optimiser. The meshless CFD solver serves to evaluate the WSS gradients and the GA optimiser serves to search for the end-to-side distal anastomosis (ETSDA) optimal shape that best minimises those gradients. We utilise a meshless CFD method to resolve hemodynamics and a GA for the purpose of optimisation. We consider three different anastomotic models: the conventional ETSDA, the Miller Cuff ETSDA and the hood ETSDA. The results reported herein demonstrate that the graft calibre should always be maximised whether a conventional or Miller Cuff ETSDA model is utilised. Also, it was noted that the Miller Cuff height should be minimised. The choice of an optimal anastomotic angle should be optimised to achieve a compromise between the concurrent minimisations of both the spatial WSS gradient and the temporal WSS gradient.

[1]  C. Zarins,et al.  Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses. , 2002, Journal of biomechanical engineering.

[2]  A Ratcliffe,et al.  Effects of flow patterns on endothelial cell migration into a zone of mechanical denudation. , 2001, Biochemical and biophysical research communications.

[3]  John A. Frangos,et al.  Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation , 2001, Circulation.

[4]  M Ojha,et al.  Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model. , 1993, Journal of biomechanics.

[5]  J. Désidéri,et al.  Multi-Objective Optimization in CFD by Genetic Algorithms , 1999 .

[6]  F. Harlow,et al.  Numerical Calculation of Time‐Dependent Viscous Incompressible Flow of Fluid with Free Surface , 1965 .

[7]  K. C. Chung A GENERALIZED FINITE-DIFFERENCE METHOD FOR HEAT TRANSFER PROBLEMS OF IRREGULAR GEOMETRIES , 1981 .

[8]  G L'Italien,et al.  Effect of compliance mismatch on vascular graft patency. , 1987, Journal of vascular surgery.

[9]  Chang Wook Ahn,et al.  On the practical genetic algorithms , 2005, GECCO '05.

[10]  Narayanaswamy Balakrishnan,et al.  An upwind finite difference scheme for meshless solvers , 2003 .

[11]  V. Sottiurai,et al.  Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. , 1989, Annals of vascular surgery.

[12]  R. Keynton,et al.  Intimal hyperplasia and wall shear in arterial bypass graft distal anastomoses: an in vivo model study. , 2001, Journal of biomechanical engineering.

[13]  Her Mann Tsai,et al.  Euler Solution Using Cartesian Grid with a Gridless Least-Squares Boundary Treatment , 2005 .

[14]  E. Kansa,et al.  Circumventing the ill-conditioning problem with multiquadric radial basis functions: Applications to elliptic partial differential equations , 2000 .

[15]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[16]  Deborah K. Lieu,et al.  Differential responsiveness of vascular endothelial cells to different types of fluid mechanical shear stress , 2007, Cell Biochemistry and Biophysics.

[17]  Alain J. Kassab,et al.  Localized Meshless Modeling of Natural-Convective Viscous Flows , 2008 .

[18]  Chang Shu,et al.  A generalized finite-difference (GFD) ALE scheme for incompressible flows around moving solid bodies on hybrid meshfree-Cartesian grids , 2006, J. Comput. Phys..

[19]  Thomas-Peter Fries,et al.  A stabilized and coupled meshfree/meshbased method for the incompressible Navier-Stokes equations-Part I: Stabilization , 2006 .

[20]  Hun Jung,et al.  Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery , 2004 .

[21]  D. Giddens,et al.  Pulsatile flow in an end-to-side vascular graft model: comparison of computations with experimental data. , 2001, Journal of biomechanical engineering.

[22]  Aleksandra B. Djurišić,et al.  Elite genetic algorithms with adaptive mutations for solving continuous optimization problems: application to modeling of the optical constants of solids , 1998 .

[23]  R. Hilbert,et al.  Multi-objective shape optimization of a heat exchanger using parallel genetic algorithms , 2006 .

[24]  Alain J. Kassab,et al.  An Efficient Localized Radial Basis Function Meshless Method for Fluid Flow and Conjugate Heat Transfer , 2007 .

[25]  R H Dean,et al.  Platelet-derived growth factor ligand and receptor expression in response to altered blood flow in vivo. , 1997, Circulation research.

[26]  Alain J. Kassab,et al.  Shape optimization of acoustic scattering bodies , 2003 .

[27]  C. Ross Ethier,et al.  Human Saphenous Vein Coronary Artery Bypass Graft Morphology, Geometry and Hemodynamics , 2005, Annals of Biomedical Engineering.

[28]  Kalyanmoy Deb,et al.  A fast and elitist multiobjective genetic algorithm: NSGA-II , 2002, IEEE Trans. Evol. Comput..

[29]  A. Kassab,et al.  Iterative domain decomposition meshless method modeling of incompressible viscous flows and conjugate heat transfer , 2006 .

[30]  U Losert,et al.  Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts. , 1995, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[31]  P L Harris,et al.  Optimising miller cuff dimensions: the influence of geometry on anastomotic flow patterns. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[32]  V. Sottiurai,et al.  Distal anastomotic intimal hyperplasia: Histocytomorphology, pathophysiology, etiology, and prevention , 1999, The International journal of angiology : official publication of the International College of Angiology, Inc.

[33]  M. Walsh,et al.  On Reducing Abnormal Hemodynamics in the Femoral End-to-Side Anastomosis: The Influence of Mechanical Factors , 2005, Annals of Biomedical Engineering.

[34]  M. Ojha Wall shear stress temporal gradient and anastomotic intimal hyperplasia. , 1994, Circulation research.

[35]  I. Loshchilov,et al.  A Comparison of Multiobjective Evolutionary Algorithms , 2009 .

[36]  R Hetzer,et al.  Reduction of intimal and medial thickening in sheathed vein grafts. , 1999, The Annals of thoracic surgery.

[37]  Lothar Thiele,et al.  Comparison of Multiobjective Evolutionary Algorithms: Empirical Results , 2000, Evolutionary Computation.

[38]  K Perktold,et al.  Experimental comparison of four methods of end‐to‐side anastomosis with expanded polytetrafluoroethylene , 2004, The British journal of surgery.

[39]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[40]  David E. Goldberg,et al.  Genetic Algorithms in Search Optimization and Machine Learning , 1988 .

[41]  Gianluigi Rozza,et al.  On optimization, control and shape design of an arterial bypass , 2005 .

[42]  T Matsumoto,et al.  Prosthetic above-knee femoropopliteal bypass grafting: results of a multicenter randomized prospective trial. Above-Knee Femoropopliteal Study Group. , 1997, Journal of vascular surgery.

[43]  J. Miller,et al.  Influence of a vein cuff on polytetrafluoroethylene grafts for primary femoropopliteal bypass , 1995, The British journal of surgery.

[44]  S Giordana,et al.  Local and global geometric influence on steady flow in distal anastomoses of peripheral bypass grafts. , 2005, Journal of biomechanical engineering.

[45]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[46]  Sung-Kie Youn,et al.  The least-squares meshfree method for the steady incompressible viscous flow , 2005 .

[47]  G. Truskey,et al.  Hemodynamic parameters and early intimal thickening in branching blood vessels. , 2001, Critical reviews in biomedical engineering.

[48]  C. Kleinstreuer,et al.  Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis. , 1997, Journal of vascular surgery.

[49]  C F Dewey,et al.  Shear stress gradients remodel endothelial monolayers in vitro via a cell proliferation-migration-loss cycle. , 1997, Arteriosclerosis, thrombosis, and vascular biology.