Modeling and experimental validation of the solar loop for absorption solar cooling system using double-glazed collectors

Solar cooling applied to buildings is without a doubt an interesting alternative for reducing energy consumption in traditional mechanical steam compression air conditioning systems. The study of these systems should have a closely purely fundamental approach including the development of numerical models in order to predict the overall installation performance. The final objective is to estimate cooling capacity, power consumption, and overall installation performance with relation to outside factors (solar irradiation, outside temperature...). The first stage in this work consists of estimating the primary energy produced by the solar collector field. The estimation of this primary energy is crucial to ensure the evaluation of the cooling capacity and therefore the cooling distribution and thermal comfort in the building. Indeed, the absorption chiller performance is directly related to its heat source. This study presents dynamic models for double glazing solar collectors and compares the results of the simulation with experimental results taken from our test bench (two collectors). In the second part, we present an extensive collector field model (36 collectors) from our solar cooling installation at The University Institute of Technology in St Pierre, Reunion Island as well as our stratified tank storage model. A comparison of the simulation results with real scale solar experimental data taken from our installation enables validation of the double glazing solar collector and stratified tank dynamic models.

[1]  Paul Bourdoukan,et al.  Potential of solar heat pipe vacuum collectors in the desiccant cooling process: Modelling and experimental results , 2008 .

[2]  W. Beckman,et al.  Solar energy thermal processes , 1974 .

[3]  Ursula Eicker,et al.  Design and performance of solar powered absorption cooling systems in office buildings , 2009 .

[4]  Simon Furbo,et al.  Theoretical variations of the thermal performance of different solar collectors and solar combi systems as function of the varying yearly weather conditions in Denmark , 2009 .

[5]  Franck Lucas,et al.  Experimental investigation of a solar cooling absorption system operating without any backup system under tropical climate , 2010 .

[6]  Marc A. Rosen,et al.  Thermal performance of integrated collector storage solar water heater with corrugated absorber surface , 2010 .

[7]  Ibrahim Atmaca,et al.  Simulation of solar-powered absorption cooling system , 2003 .

[8]  Philip Haves,et al.  Efficient solution strategies for building energy system simulation , 2001 .

[9]  Armando C. Oliveira,et al.  Energy and economic analysis of an integrated solar absorption cooling and heating system in different building types and climates , 2009 .

[10]  W. Beckman,et al.  A design procedure for solar heating systems , 1976 .

[11]  Mehmet Esen Thermal performance of a solar cooker integrated vacuum-tube collector with heat pipes containing different refrigerants , 2004 .

[12]  Mehmet Esen,et al.  Experimental investigation of a two-phase closed thermosyphon solar water heater , 2005 .

[13]  M. Venegas,et al.  Optimum hot water temperature for absorption solar cooling , 2009 .

[14]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[15]  D. C. Larson,et al.  Calculation of the top loss coefficient of a flat-plate collector , 1981 .

[16]  Felix Ziegler,et al.  Sorption heat pumping technologies: Comparisons and challenges , 2009 .

[17]  Darine Zambrano,et al.  Model development and validation of a solar cooling plant , 2008 .

[18]  Shigenao Maruyama,et al.  Theoretical approach of a flat plate solar collector with clear and low-iron glass covers taking into account the spectral absorption and emission within glass covers layer , 2005 .