A system for distal fixation of intramedullary nails

This article describes the design and construction of an electronic device to assist orthopedic surgeons in the intramedullary nailing of long bones. The objective of the system is to reduce the cumulative radiation to which surgeons are exposed while performing the operation, as well as reduce the time required to complete the task. The system uses the magnetic flux of permanent magnets and electronic sensors to determine, without the need for a fluoroscope, the position of the distal hole in the rod. Tests show the system is feasible.

[1]  Tianmiao Wang,et al.  BPOR: a fluoroscopy-based robot navigating system for distal locking of intramedullary nails , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[2]  C. Court-Brown,et al.  Closed intramedullary tibial nailing. Its use in closed and type I open fractures. , 1990, The Journal of bone and joint surgery. British volume.

[3]  L. Joskowicz,et al.  FRACAS: a system for computer-aided image-guided long bone fracture surgery. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[4]  C. Krettek,et al.  A new mechanical aiming device for the placement of distal interlocking screws in femoral nails , 1998, Archives of Orthopaedic and Trauma Surgery.

[5]  D. Tanna Interlocking tibial nailing without an image intensifier. , 1994, The Journal of bone and joint surgery. British volume.

[6]  S. Madan,et al.  Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb. , 2002, Injury.

[7]  Klaus Michael Stürmer,et al.  Exposure of the surgeon to radiation during surgery , 1998, International Orthopaedics.

[8]  Roger Phillips,et al.  Recovery of distal hole axis in intramedullary nail trajectory planning , 2001, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164).

[9]  S. Skjeldal,et al.  Interlocking medullary nails — Radiation doses in distal targeting , 2004, Archives of orthopaedic and traumatic surgery.

[10]  Arild Aamodt,et al.  External fixation versus locked intramedullary nailing in tibial shaft fractures: a prospective, randomised study of 78 patients , 2005, Archives of Orthopaedic and Trauma Surgery.

[11]  Vicente Rivera Hernández,et al.  Método alternativo de bloqueo distal para clavos femorales huecos sin el uso de intensificador de imágenes, mediante una guía de localización interna (GLI) , 2001 .

[12]  C. Krettek,et al.  Analyse implantationsbedingter Nagelverformung und röntgenmorphometrische Untersuchungen als Grundlage für ein Zielgerät zur distalen Verriegelung ohne Röntgenbildverstärker , 1996, Der Unfallchirurg.

[13]  S Stenzler,et al.  Exposure of the orthopaedic surgeon to radiation. , 1993, The Journal of bone and joint surgery. American volume.

[14]  T. Shope,et al.  Radiation-induced skin injuries from fluoroscopy. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.