Accuracy of home blood pressure measurement: the ACCURAPRESS study – a proposal of Young Investigator Group of the Italian Hypertension Society (Società Italiana dell’Ipertensione Arteriosa)

Abstract Purpose Home blood pressure monitoring (HBPM) might be considered a valid alternative to ambulatory blood pressure monitoring (ABPM) for both the diagnosis and management of hypertension. Correct information on how to perform HBPM are crucial for its reliability. The aim of the present survey was to assess if hypertensive patients followed current recommendation on how to correctly perform HBPM measurements. Materials and methods The survey included 30 different items on how to perform the HBPM. It was developed by the ‘Young Investigators’ group of the Italian Society of Arterial Hypertension (SIIA) and it was administered during the office visit between May 2019 and December 2021. Results A total of 643 hypertensive patients participated in the study. Main results show that, despite the rate of informed patients was relatively high (71% of the whole population), unacceptable number of patients did not follow indications on how to perform a correct HBPM. Patients who were informed on how to measure home BP had a significantly higher rate of correct position during measurement (78 vs. 22%, p < 0.01), avoidance of talking and moving during measurement (68 vs. 32%, p < 0.0001), and correct number and time interval between two measurements (85 vs. 15%, p < 0.001). More accurate measurements of home BP were associated with less prevalence of carotid plaque. Conclusions Correct performance for HBPM is low among patients treated in Italian hypertension centers. These findings shed light on the importance of correct HBPM measurements for the detection of accurate BP values for the proper management of hypertensive patients.

[1]  P. Gosse,et al.  Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension , 2021, Journal of hypertension.

[2]  Kwang-il Kim,et al.  Effect of home blood pressure monitoring for blood pressure control in hypertensive patients taking multiple antihypertensive medications including fimasartan (the FORTE study) , 2020, Clinical Hypertension.

[3]  Thomas Kahan,et al.  [2018 ESC/ESH Guidelines for the management of arterial hypertension]. , 2019, Kardiologia polska.

[4]  James Brian Byrd,et al.  Out-of-Office Blood Pressure Monitoring in 2018 , 2018, JAMA.

[5]  G. Lip,et al.  2018 ESC/ESH Guidelines for the management of arterial hypertension. , 2018, European heart journal.

[6]  S. Ulusoy,et al.  Home sphygmomanometers can help in the control of blood pressure: a nationwide field survey , 2018, Hypertension Research.

[7]  Wilbert S Aronow,et al.  2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. , 2017, Journal of the American College of Cardiology.

[8]  C. Dufouil,et al.  Impact of home blood pressure monitoring on blood pressure control in older individuals: a French randomized study , 2017, Journal of hypertension.

[9]  G. de Simone,et al.  Left Ventricular Hypertrophy Regression During Antihypertensive Treatment in an Outpatient Clinic (the Campania Salute Network) , 2017, Journal of the American Heart Association.

[10]  Mark S. Horswill,et al.  Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings: a systematic review , 2016, Journal of hypertension.

[11]  V. Tikhonoff,et al.  Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study , 2016, Hypertension.

[12]  Uneven Accuracy of Home Blood Pressure Measurement: A Multicentric Survey , 2015, Journal of clinical hypertension.

[13]  Peter Ahrendt,et al.  Measurement adherence in the blood pressure self-measurement room. , 2013, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[14]  G. Stergiou,et al.  Home versus ambulatory and office blood pressure in predicting target organ damage in hypertension: a systematic review and meta-analysis , 2012, Journal of hypertension.

[15]  J. Baguet Out-of-office blood pressure: from measurement to control , 2012, Integrated blood pressure control.

[16]  Thomas Skjødeberg Toftegaard,et al.  Challenges in Blood Pressure Self-Measurement , 2012, International journal of telemedicine and applications.

[17]  N. Roberts,et al.  Relative effectiveness of clinic and home blood pressure monitoring compared with ambulatory blood pressure monitoring in diagnosis of hypertension: systematic review , 2011, BMJ : British Medical Journal.

[18]  Janusz Kaczorowski,et al.  Home blood pressure monitoring among Canadian adults with hypertension: results from the 2009 Survey on Living with Chronic Diseases in Canada. , 2010, The Canadian journal of cardiology.

[19]  Roger Watson,et al.  The effect of crossing legs on blood pressure in hypertensive patients. , 2010, Journal of clinical nursing.

[20]  Roberto Sega,et al.  Prognostic Value of Ambulatory and Home Blood Pressures Compared With Office Blood Pressure in the General Population: Follow-Up Results From the Pressioni Arteriose Monitorate e Loro Associazioni (PAMELA) Study , 2005, Circulation.

[21]  K. Kohara,et al.  Home blood pressure is a better predictor of carotid atherosclerosis than office blood pressure in community-dwelling subjects. , 2004, Hypertension research : official journal of the Japanese Society of Hypertension.

[22]  Gilles Chatellier,et al.  Cardiovascular prognosis of "masked hypertension" detected by blood pressure self-measurement in elderly treated hypertensive patients. , 2004, JAMA.

[23]  Giuseppe Andronico,et al.  Value of Home Blood Pressures as Predictor of Target Organ Damage in Mild Arterial Hypertension , 2002, Journal of cardiovascular risk.

[24]  W. Cushman,et al.  Effect of back support and stethoscope head on seated blood pressure determinations. , 1990, American journal of hypertension.