Evaluation of the nerve fiber layer and macula in the eyes of healthy children using spectral-domain optical coherence tomography.

PURPOSE To determine the normative values of the peripapillary retinal nerve fiber layer (RNFL), macular thickness, and macular volume in healthy children using spectral-domain optical coherence tomography (SD-OCT) and analyze the correlation of such values with age, refraction error, and biometric measurements. DESIGN Observational case series. METHODS This institutional study involved 107 eyes from 107 healthy pediatric patients (54 female, 53 male) with ages between 6 and 16 years. After the biometric measurements and refractive error values (in spherical equivalent) of the cases were obtained, the peripapillary RNFL, macular thickness, and macular volume values were calculated using the Spectralis OCT device. RESULTS Among the study group, with an average age of 10.46 ± 2.94 years, the average axial length (AL) was 23.33 ± 0.89 mm; the average spherical equivalent (SE) value was -0.27 ± 0.99 diopter. The average peripapillary RNFL thickness was 106.45 ± 9.41 μm; the average macular thickness was 326.44 ± 14.17 μm; and the average macular volume was 0.257 ± 0.011 mm(3). The aforementioned OCT measurements were not significantly correlated with age, SE, or AL values (P > .05 for all). CONCLUSIONS This study reports SD-OCT findings among healthy pediatric cases. SD-OCT can be reliably used for pediatric patients because of its short exposure time and high degree of image resolution.

[1]  E Reichel,et al.  Topography of diabetic macular edema with optical coherence tomography. , 1998, Ophthalmology.

[2]  I. Scott,et al.  Expert agreement in evaluating the optic disc for glaucoma. , 1992, Ophthalmology.

[3]  Paul Mitchell,et al.  Distribution of macular thickness by optical coherence tomography: findings from a population-based study of 6-year-old children. , 2006, Investigative ophthalmology & visual science.

[4]  Mircea Mujat,et al.  Spectral Domain Optical Coherence Tomography and Glaucoma , 2008, International ophthalmology clinics.

[5]  E. Balestrazzi,et al.  Unilateral amblyopia: An optical coherence tomography study. , 2009, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[6]  A. Alm,et al.  Retinal nerve fibre layer thickness in full‐term children assessed with Heidelberg retinal tomography and optical coherence tomography: normal values and interocular asymmetry , 2011, Acta ophthalmologica.

[7]  F. Medeiros,et al.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. , 2005, American journal of ophthalmology.

[8]  J. Duker,et al.  Imaging of macular diseases with optical coherence tomography. , 1995, Ophthalmology.

[9]  A. Sommer,et al.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. , 1991, Archives of ophthalmology.

[10]  Optical Coherence Tomography Findings of Active Ocular Toxoplasmosis Complicated with Serous Macular Detachment: Case Report , 2010 .

[11]  R. Klein,et al.  The Beaver Dam Eye Study: visual acuity. , 1991, Ophthalmology.

[12]  R. Knighton,et al.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. , 2005, Investigative ophthalmology & visual science.

[13]  J. Duker,et al.  Optical coherence tomography of age-related macular degeneration and choroidal neovascularization. , 1996, Ophthalmology.

[14]  Robert N Weinreb,et al.  Evaluation of retinal nerve fiber layer progression in glaucoma: a comparison between spectral-domain and time-domain optical coherence tomography. , 2011, Ophthalmology.

[15]  H. Quigley,et al.  Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons. , 2000, Investigative ophthalmology & visual science.

[16]  Douglas R. Anderson,et al.  Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. , 2007, Ophthalmology.

[17]  P. Mitchell,et al.  Peripapillary retinal nerve fiber layer thickness in a population of 6-year-old children: findings by optical coherence tomography. , 2006, Ophthalmology.

[18]  A. Alm,et al.  A population‐based study of macular thickness in full‐term children assessed with Stratus OCT: normative data and repeatability , 2009, Acta ophthalmologica.

[19]  Barry Cense,et al.  Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging. , 2005, Archives of ophthalmology.

[20]  G. Mcgwin,et al.  Discrimination between glaucomatous and nonglaucomatous eyes using quantitative imaging devices and subjective optic nerve head assessment. , 2006, Investigative ophthalmology & visual science.

[21]  Sung Yong Kang,et al.  Detection of Glaucoma by Spectral Domain-scanning Laser Ophthalmoscopy/Optical Coherence Tomography (SD-SLO/OCT) and Time Domain Optical Coherence Tomography , 2011, Journal of glaucoma.

[22]  Effects of refraction and axial length on childhood optic disk parameters measured by optical coherence tomography. , 2007, American journal of ophthalmology.

[23]  Mahnaz Shahidi,et al.  Thickness mapping of retinal layers by spectral-domain optical coherence tomography. , 2010, American journal of ophthalmology.

[24]  S. Asrani,et al.  Optical coherence tomography in the eyes of normal children. , 2009, Archives of ophthalmology.

[25]  K. Sung,et al.  Comparison of retinal nerve fiber layer thickness measured by Cirrus HD and Stratus optical coherence tomography. , 2009, Ophthalmology.

[26]  J. Jonas,et al.  Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes. , 1988, Investigative ophthalmology & visual science.

[27]  William J Feuer,et al.  Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography. , 2009, Ophthalmology.

[28]  R. Beck,et al.  Retinal nerve fiber layer thickness in amblyopic eyes. , 2007, American journal of ophthalmology.

[29]  B. Alamouti,et al.  Retinal thickness decreases with age: an OCT study , 2003, The British journal of ophthalmology.

[30]  M. Hangai,et al.  Detection of localized retinal nerve fiber layer defects in glaucoma using enhanced spectral-domain optical coherence tomography. , 2011, Ophthalmology.

[31]  Andrew K C Lam,et al.  Retinal Nerve Fiber Layer Thickness in Normal Hong Kong Chinese Children Measured With Optical Coherence Tomography , 2010, Journal of glaucoma.

[32]  Michael F Chiang,et al.  Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography. , 2006, Ophthalmology.

[33]  Parul Sony,et al.  Diagnostic capability of optical coherence tomography in evaluating the degree of glaucomatous retinal nerve fiber damage. , 2006, Investigative ophthalmology & visual science.

[34]  F. Medeiros,et al.  Differences in visual function and optic nerve structure between healthy eyes of blacks and whites. , 2005, Archives of ophthalmology.

[35]  A. Tafreshi,et al.  Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. , 2011, American journal of ophthalmology.

[36]  H. Quigley Number of people with glaucoma worldwide. , 1996, The British journal of ophthalmology.

[37]  L. Sakata,et al.  Optical coherence tomography of the retina and optic nerve – a review , 2009, Clinical & experimental ophthalmology.

[38]  E A Swanson,et al.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. , 1995, Archives of ophthalmology.

[39]  Joel S Schuman,et al.  Optic nerve head and retinal nerve fiber layer analysis: a report by the American Academy of Ophthalmology. , 2007, Ophthalmology.

[40]  L. Zangwill,et al.  The retinal nerve fiber layer thickness in ocular hypertensive, normal, and glaucomatous eyes with optical coherence tomography. , 2000, Archives of ophthalmology.

[41]  Xiaodong Sun,et al.  Optical Coherence Tomography Measurements of Retinal Nerve Fiber Layer Thickness in Chinese Children and Teenagers , 2010, Journal of glaucoma.

[42]  G. Tomita,et al.  Evaluation of the Effect of Aging on the Retinal Nerve Fiber Layer Thickness Using Scanning Laser Polarimetry , 1995, Journal of glaucoma.

[43]  J. Jonas,et al.  Human optic nerve fiber count and optic disc size. , 1992, Investigative ophthalmology & visual science.

[44]  Ki Ho Park,et al.  Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fiber layer defects in preperimetric glaucoma. , 2010, Investigative ophthalmology & visual science.

[45]  Maciej Wojtkowski,et al.  Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning. , 2007, Investigative ophthalmology & visual science.

[46]  Rohit Varma,et al.  Optical tomography-measured retinal nerve fiber layer thickness in normal latinos. , 2003, Investigative ophthalmology & visual science.

[47]  A. Fercher,et al.  In vivo human retinal imaging by Fourier domain optical coherence tomography. , 2002, Journal of biomedical optics.

[48]  P. Mitchell,et al.  Macular thickness, retinal thickness, and optic disk parameters in dominant compared with nondominant eyes. , 2009, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[49]  Malgorzata Mrugacz,et al.  Optical Coherence Tomography Measurement of the Retinal Nerve Fiber Layer in Normal and Juvenile Glaucomatous Eyes , 2005, Ophthalmologica.

[50]  Wing-Ho Yung,et al.  Comparison of macular and peripapillary measurements for the detection of glaucoma: an optical coherence tomography study. , 2005, Ophthalmology.

[51]  A. Negi,et al.  Association of retinal nerve fibre layer thickness measured by confocal scanning laser ophthalmoscopy and optical coherence tomography with disc size and axial length , 2008, British Journal of Ophthalmology.

[52]  E. Blumenthal,et al.  Morphometric analysis of human peripapillary retinal nerve fiber layer thickness. , 2008, Investigative ophthalmology & visual science.

[53]  R. Ramakrishnan,et al.  Retinal nerve fibre layer thickness measurements in normal Indian population by optical coherence tomography. , 2006, Indian journal of ophthalmology.

[54]  D E Gaasterland,et al.  The Advanced Glaucoma Intervention Study (AGIS): 10. Variability among academic glaucoma subspecialists in assessing optic disc notching. , 2001, Transactions of the American Ophthalmological Society.