Quality control techniques for routine analysis with liquid chromatography in laboratories.

The process of quality assurance should demonstrate that the method and the analytical instrument provide accurate and precise results, or whether deterioration occurs. For this, the quality procedure should include tests which provide information on the characteristic performance of the method. According to the recent literature, useful procedures contributing to the overall quality of analytical results are illustrated in relation with liquid chromatography. Parameters examined are carry-over, column statement, accuracy and precision. The performance of the whole system from the extraction to measurement of analytes of interest must be monitored with control charts. Data representing the routine performance of chromatographic equipment systems and method allow predicting long-term uncertainties and confidence intervals.

[1]  Ph. Quevauviller,et al.  Use of reference materials in accreditation systems for environmental laboratories , 1998 .

[2]  I. Novozamsky,et al.  Quality aspects in laboratories for soil and plant analysis , 1996 .

[3]  J. Lawrence Quality assurance for environmental monitoring programs , 1991 .

[4]  Joachim Ermer,et al.  Validation in pharmaceutical analysis. Part II: Central importance of precision to establish acceptance criteria and for verifying and improving the quality of analytical data. , 2005, Journal of pharmaceutical and biomedical analysis.

[5]  W. R. Kelly,et al.  Standard Reference Materials® (SRMs) for measurement of inorganic environmental contaminants , 2006, Analytical and Bioanalytical Chemistry.

[6]  Antonia Garrido Frenich,et al.  Internal quality-control and laboratory-management tools for enhancing the stability of results in pesticide multi-residue analytical methods , 2004 .

[7]  B. M. Simonet,et al.  Quality control in qualitative analysis , 2005 .

[8]  P. Quevauviller Improvement of quality control of speciation analysis using hyphenated techniques A decade of progress within the European Community , 1996 .

[9]  G. Maldener Requirements and tests for HPLC apparatus and methods in pharmaceutical quality control , 1989 .

[10]  Thomas Steiger,et al.  COMAR2—the internet database for certified reference materials , 2004, Analytical and bioanalytical chemistry.

[11]  B. Renger System performance and variability of chromatographic techniques used in pharmaceutical quality control. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[12]  H.-W. Hembeck GLP and other Quality Assurance Systems – A comparison , 2002 .

[13]  A. Marchetto,et al.  Ion chromatography performances evaluated from the third AQUACON freshwater analysis interlaboratory exercise , 2004 .

[14]  Bernard Griepink,et al.  Interlaboratory studies as a tool for many purposes: proficiency testing, learning exercises, quality control and certification of matrix materials , 1993 .

[15]  P. Masson,et al.  Quality control procedures for chloride and nitrate ions analysis in plant samples by ion chromatography , 2005 .

[16]  D. Patterson,et al.  Quantification of monohydroxy-PAH metabolites in urine by solid-phase extraction with isotope dilution-GC–MS , 2002, Analytical and bioanalytical chemistry.

[17]  F. S. Stover,et al.  Statistical quality control applied to ion chromatography calibrations , 1998 .

[18]  Y. Kalra,et al.  Handbook of Reference Methods for Plant Analysis , 1997 .

[19]  A. G. Frenich,et al.  Application of internal quality control to the analysis of quaternary ammonium compounds in surface and groundwater from Andalusia (Spain) by liquid chromatography with mass spectrometry. , 2004, Journal of chromatography. A.

[20]  L Escuder-Gilabert,et al.  Chromatographic multivariate quality control of pharmaceuticals giving strongly overlapped peaks based on the chromatogram profile. , 2004, Journal of chromatography. A.

[21]  C. Lucy What are the unanswered (and unasked) questions in ion analysis , 1998 .

[22]  Ilya Kuselman,et al.  Analysis of long-term distributions of calibration parameters and calibration intervals for an atomic absorption spectrophotometer , 2001 .

[23]  Jean-Jacques Daudin,et al.  Homogeneity check of agricultural and food industries samples using near infrared spectroscopy , 2003, Analytical and Bioanalytical Chemistry.

[24]  L. Huber Validation and Qualification in Analytical Laboratories , 1998 .

[25]  S. Caroli Certified reference materials : use, manufacture and certification , 1993 .

[26]  L'apport des méthodes statistiques dans la maîtrise de la qualité des analyses , 1999 .

[27]  Jordi Segura,et al.  Strategies for internal quality control in antidoping analyses , 2002 .

[28]  D L Massart,et al.  Validation of bioanalytical chromatographic methods. , 1998, Journal of pharmaceutical and biomedical analysis.

[29]  G. Frison,et al.  Quality control in toxicological analysis. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[30]  Tina Engelhard,et al.  A comparison of the complimentary and different issues in ISO/IEC 17025 and OECD GLP , 2003 .

[31]  L. D. Eicher The ISO 9000 family of International Standards , 1997 .

[32]  P. Bedson,et al.  The development and application of guidance on EQ of analytical instruments: High performance liquid chromatography , 1999 .

[33]  F. Javier Llorens-Montes,et al.  Self-implementation of ISO 9001 versus external support: an examination in laboratories involved in chemical measurement , 2005 .

[34]  Jürgen Kuballa,et al.  Benefits of high resolution IC–ICP–MS for the routine analysis of inorganic and organic arsenic species in food products of marine and terrestrial origin , 2003, Analytical and bioanalytical chemistry.

[35]  J. Vial,et al.  How to better define the characteristics of dispersion of results in liquid chromatographic analyses through an interlaboratory study. Example of collaborative studies on ketoprofen and spiramycin. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[36]  W. Thormann,et al.  Therapeutic drug monitoring of lamotrigine using capillary electrophoresis. Evaluation of assay performance and quality assurance over a 4-year period in the routine arena. , 2002, Journal of chromatography. A.