Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors

In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI2 and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples.

[1]  Susumu Adachi,et al.  Improvement of temporal response and output uniformity of polycrystalline CdZnTe films for high-sensitivity x-ray imaging , 2003, SPIE Medical Imaging.

[2]  Arokia Nathan,et al.  Amorphous silicon active pixel sensor readout circuit for digital imaging , 2003 .

[3]  A. Peacock,et al.  The effect of carrier diffusion on the characteristics of semiconductor imaging arrays , 2004 .

[4]  J A Rowlands,et al.  X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain. , 2002, Medical physics.

[5]  F. Thibault,et al.  Digital detectors for mammography: the technical challenges , 2004, European Radiology.

[6]  Larry Partain,et al.  Dark current and DQE improvements of mercuric iodide medical imagers , 2007, SPIE Medical Imaging.

[7]  K. Taketoshi,et al.  An avalanche-mode amorphous Selenium photoconductive layer for use as a camera tube target , 1987, IEEE Electron Device Letters.

[8]  Roberto S. Murphy-Arteaga,et al.  n型非晶質SiGe:H/p型結晶質Siヘテロ接合ダイオードの伝導機構に及ぼすa‐SiGe:H厚の影響 , 2005 .

[9]  M. Z. Kabir,et al.  Effect of repeated x-ray exposure on the resolution of amorphous selenium based x-ray imagers. , 2010, Medical physics.

[10]  Arokia Nathan,et al.  Amorphous silicon technology for large area digital X-ray and optical imaging , 2002, Microelectron. Reliab..

[11]  Isaac N. Bankman,et al.  Handbook of medical imaging , 2000 .

[12]  Rena Lee,et al.  Investigation of PbI2 Film Fabricated by a New Sedimentation Method as an X-ray Conversion Material , 2010 .

[13]  Martin J Yaffe,et al.  A CdZnTe slot-scanned detector for digital mammography. , 2002, Medical physics.

[14]  Kenkichi Tanioka,et al.  Ultrahigh-sensitivity New Super-HARP camera , 1996 .

[15]  Habib Mani,et al.  Dark current in multilayer amorphous selenium x-ray imaging detectors , 2008 .

[16]  Ezio Caroli,et al.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications , 2009, Sensors.

[17]  C. Mun,et al.  Effect of Annealing on the X-ray Detection Properties of Nano-sized Polycrystalline Lead Oxide Films , 2008 .

[18]  Olivier Tousignant,et al.  An a-Si Active Pixel Sensor (APS) Array for Medical X-ray Imaging , 2010, IEEE Transactions on Electron Devices.

[20]  Haim Hermon,et al.  High-flux x-ray response of composite mercuric iodide detectors , 1999, Optics & Photonics.

[21]  Safa Kasap,et al.  DQE of photoconductive x-ray image detectors: application to a-Se , 2002 .

[23]  John A. Rowlands,et al.  Digital radiology using self-scanned readout of amorphous selenium: design considerations for mammography , 1995, Medical Imaging.

[24]  JengPing Lu,et al.  New materials and processes for flat panel X-ray detectors , 2003 .

[25]  Satoshi Yamada,et al.  Large-area deposition of a polycrystalline CdZnTe film and its applicability to x-ray panel detectors with superior sensitivity , 2002, SPIE Medical Imaging.

[27]  Safa Kasap,et al.  Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes , 2009 .

[28]  J. Yorkston Recent developments in digital radiography detectors , 2007 .

[29]  Kanai S. Shah,et al.  Electronic transport in polycrystalline Pbl2 films , 1999 .

[30]  T. Mertelmeier,et al.  Modulation transfer function of a selenium-based digital mammography system , 2004, IEEE Transactions on Nuclear Science.

[31]  Bo Zhao,et al.  Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system. , 2008, Medical physics.

[32]  Safa Kasap,et al.  Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors , 2004 .

[33]  Safa Kasap,et al.  X-ray sensitivity of photoconductors: application to stabilized a-Se , 2000 .

[34]  Paul J. Sellin,et al.  Recent advances in compound semiconductor radiation detectors , 2003 .

[35]  Kenkichi Tanioka,et al.  X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise. , 2007, Medical physics.

[36]  W. Zhao,et al.  Digital radiology using active matrix readout: amplified pixel detector array for fluoroscopy. , 1999, Medical physics.

[37]  J A Rowlands,et al.  X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.

[38]  M. Z. Kabir,et al.  Recent advances in X-ray photoconductors for direct conversion X-ray image detectors , 2006 .

[39]  S. Kasap,et al.  Density of localized electronic states in a-Se from electron time-of-flight photocurrent measurements , 2005 .

[40]  John A. Rowlands,et al.  Flat Panel Detectors for Digital Radiography , 2000 .

[41]  I. Blevis,et al.  Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. , 1997, Medical physics.

[42]  A. Nathan,et al.  Readout circuit in active pixel sensors in amorphous silicon technology , 2001, IEEE Electron Device Letters.

[43]  Arokia Nathan,et al.  Noise performance of a current-mediated amplified pixel for large-area medical imaging , 2004 .

[44]  W. Kalender,et al.  Flat-detector computed tomography (FD-CT) , 2007, European Radiology.

[45]  Qihua Zhao,et al.  Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography. , 2007, Medical physics.

[46]  Martin Hoheisel,et al.  Review of medical imaging with emphasis on X-ray detectors , 2006 .

[47]  Zhong He,et al.  Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectors , 2001 .

[48]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: geometrical and effective fill factors. , 1998, Medical physics.

[49]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: inherent spatial resolution. , 1995, Medical physics.

[50]  J. Lai,et al.  High dynamic range active pixel sensor arrays for digital x-ray imaging using a-Si:H , 2006 .

[51]  Qihua Zhao,et al.  Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2. , 2008, Physics in medicine and biology.

[52]  F. Taghibakhsh,et al.  Two-Transistor Active Pixel Sensor Readout Circuits in Amorphous Silicon Technology for High-Resolution Digital Imaging Applications , 2008, IEEE Transactions on Electron Devices.

[53]  Richard L. Van Metter,et al.  Handbook of Medical Imaging , 2009 .

[54]  Qihua Zhao,et al.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors. , 2009, Medical physics.

[55]  S. Kasap,et al.  An interrupted field time‐of‐flight (IFTOF) technique in transient photoconductivity measurements , 1990 .

[56]  Anthony J. Peacock,et al.  Resolution degradation of semiconductor detectors due to carrier trapping , 2005 .

[57]  Wei Zhao,et al.  Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium. , 2005, Medical physics.

[58]  Qihua Zhao,et al.  An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays. , 2009, Medical physics.

[59]  O. Rubel,et al.  Generalized lucky-drift model for impact ionization in semiconductors with disorder , 2011, Journal of physics. Condensed matter : an Institute of Physics journal.

[60]  I A Cunningham,et al.  Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors. , 2006, Medical physics.

[61]  K.S. Karim,et al.  Digital X-Ray Imaging Using Avalanche a-Se Photoconductor , 2010, IEEE Sensors Journal.

[62]  Rebecca Fahrig,et al.  Design, Performance, and Applications of a Hybrid X-Ray/MR System for Interventional Guidance , 2008, Proceedings of the IEEE.

[63]  R. Shaw,et al.  The Equivalent Quantum Efficiency of the Photographic Process , 1963 .

[64]  S. Kasap Charge transport in selenium based amorphous xerographic photoreceptors , 1983 .

[65]  S. Kasap,et al.  Lucky-drift model for impact ionization in amorphous semiconductors , 2009 .

[66]  J. Plešek,et al.  Nonlinear elastic behavior in compression of thermally sprayed materials , 2002 .

[67]  A. Shor,et al.  CdTe and CdZnTe Room-Temperature X-Ray and Gamma Ray Detectors and Imaging Systems , 1997 .

[68]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology. , 1995, Medical physics.

[69]  M. Z. Kabir,et al.  The effects of large signals on charge collection in radiation detectors : Application to amorphous selenium detectors , 2006 .

[70]  J. Rowlands,et al.  Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI. , 2008, Medical physics.

[71]  M. Z. Kabir Effects of charge carrier trapping on polycrystalline PbO x-ray imaging detectors , 2008 .

[72]  I. Cunningham,et al.  On the Development of Digital Radiography Detectors : A Review , 2008 .

[73]  Arokia Nathan,et al.  Low-noise pixel architecture for advanced diagnostic medical x-ray imaging applications , 2006, SPIE Medical Imaging.

[74]  S. Kasap Dark decay of electrostatic surface potential on dielectrics via bulk space-charge buildup , 1989 .

[75]  M. Braiman,et al.  Novel mercuric iodide polycrystalline nuclear particles counters , 1996 .

[76]  M. Z. Kabir,et al.  Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trapping , 2003 .

[77]  Safa Kasap,et al.  Direct-conversion flat-panel X-ray image detectors , 2002 .

[78]  Thomas J. Meyer,et al.  Effect of 1/f noise in integrating sensors and detectors , 2011, IET Circuits Devices Syst..

[79]  J. Anthony Seibert,et al.  Flat-panel detectors: how much better are they? , 2006, Pediatric Radiology.

[80]  L. Antonuk,et al.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. , 2010, Medical physics.

[83]  J A Rowlands,et al.  Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. , 2004, Medical physics.

[84]  John A Rowlands,et al.  Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system. , 2008, Medical physics.

[85]  Denny L. Y. Lee,et al.  New digital detector for projection radiography , 1995, Medical Imaging.

[86]  Ho Kyung Kim Analytical model for incomplete signal generation in semiconductor detectors , 2006 .

[87]  Safa Kasap,et al.  Reduction of the dark current in stabilized a-Se based X-ray detectors , 2006 .

[88]  Sunetra K. Mendis,et al.  CMOS active pixel image sensor , 1994 .

[89]  Kanai S. Shah,et al.  X-ray imaging with PbI2-based A-Si:H flat panel detectors , 2001 .

[90]  Maximilian F Reiser,et al.  Advances in digital radiography: physical principles and system overview. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[91]  K. Arlauskas,et al.  Features of Hot Carriers in Amorphous Selenium , 1983 .

[92]  Safa Kasap,et al.  Amorphous selenium as an X-ray photoconductor , 2004 .

[93]  Ulrich Neitzel,et al.  Status and prospects of digital detector technology for CR and DR. , 2005, Radiation protection dosimetry.

[94]  Safa Kasap,et al.  Direct-conversion flat-panel X-ray image sensors for digital radiography , 2002, Proc. IEEE.

[95]  Qihua Zhao,et al.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. , 2010, Medical physics.

[96]  J. Krenn,et al.  Improvement of light extraction from high-power flip-chip light-emitting diodes by femtosecond laser direct structuring of the sapphire backside surface , 2008 .

[97]  Kenneth C. Young,et al.  Breast Cancer: Advances in X-ray mammography , 2010 .

[99]  Paul J. Sellin,et al.  Thick film compound semiconductors for X-ray imaging applications , 2006 .

[100]  Martin Spahn,et al.  Flat detectors and their clinical applications , 2005, European Radiology.

[101]  S. Kasap,et al.  Charge transport and electron-hole-pair creation energy in stabilized a-Se x-ray photoconductors , 1999 .

[102]  Wei Zhao,et al.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector. , 2003, Medical physics.

[103]  S. Kasap,et al.  Effect of aging on glass transformation measurements by temperature modulated DSC , 2002 .

[104]  S. Kröger,et al.  Bismuth tri-iodide polycrystalline films for X-ray direct and digital imagers , 2009 .

[105]  H. B. Barber,et al.  Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.

[106]  J. Iwanczyk,et al.  HgI/sub 2/ polycrystalline films for digital X-ray imagers , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[107]  S. Bloom,et al.  Electron-Hole-Pair Creation Energies in Semiconductors , 1975 .

[108]  Kenkichi Tanioka,et al.  Avalanche multiplication phenomenon in amorphous semiconductors : Amorphous selenium versus hydrogenated amorphous silicon , 2007 .

[109]  M. Z. Kabir,et al.  Sensitivity of stabilized a-Se based X-ray photoconductors , 2006 .

[110]  Habib Mani,et al.  Spatial and temporal image characteristics of a real-time large area a-Se x-ray detector , 2005, SPIE Medical Imaging.

[111]  Safa Kasap,et al.  Charge collection and absorption-limited sensitivity of x-ray photoconductors: Applications to a-Se and HgI2 , 2002 .

[113]  Denny L. Y. Lee,et al.  Discussion on resolution and dynamic range of Se-TFT direct digital radiographic detector , 1996, Medical Imaging.

[114]  S. Kasap,et al.  Electronic and thermal properties of magnesium‐doped a‐Se films , 2009 .

[115]  Richard L. Weisfield,et al.  Two Dimensional Amorphous Silicon Image Sensor Arrays , 1995 .

[116]  Olivier Bonnaud,et al.  Low-frequency noise in low temperature unhydrogenated polysilicon thin film transistors , 2000 .

[117]  K. Arlauskas,et al.  Impact Ionization and Mobilities of Charge Carriers at High Electric Fields in Amorphous Selenium , 1980, May 16.

[118]  Kenkichi Tanioka,et al.  Lucky drift impact ionization in amorphous semiconductors , 2004 .

[119]  Robert A. Street,et al.  Thick films of X-ray polycrystalline mercuric iodide detectors , 2001 .

[120]  Kanai S. Shah,et al.  Comparison of PbI2 and HgI2 for direct detection active matrix x-ray image sensors , 2002 .

[121]  J A Rowlands,et al.  X-ray imaging with amorphous selenium: pulse height measurements of avalanche gain fluctuations. , 2006, Medical physics.

[122]  Kenkichi Tanioka,et al.  X-ray imaging using avalanche multiplication in amorphous selenium: investigation of intrinsic avalanche noise. , 2007, Medical physics.

[123]  Daniela Dragoman,et al.  Optical analogue of a type II semiconductor heterostructure , 2000 .

[124]  Sung-Ho Cho,et al.  Quantitative evaluation of mercuric iodide thick film for x-ray imaging device , 2006, SPIE Medical Imaging.

[125]  M. Schieber,et al.  Near single-crystal electrical properties of polycrystalline HgI/sub 2/ produced by physical vapor deposition , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[126]  Safa Kasap,et al.  Amorphous Semiconductors Usher in Digital X‐Ray Imaging , 1997 .

[127]  Claude A. Klein,et al.  Bandgap Dependence and Related Features of Radiation Ionization Energies in Semiconductors , 1968 .

[128]  J A Rowlands,et al.  Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors. , 2001, Medical physics.

[129]  Matthias Simon,et al.  PbO as direct conversion x-ray detector material , 2004, SPIE Medical Imaging.

[130]  Wei Zhao,et al.  Amorphous selenium flat panel detectors for medical applications , 2005 .

[131]  T. Peter Brody The birth and early childhood of active matrix — A personal memoir , 1996 .

[132]  J A Rowlands,et al.  The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors. , 2007, Medical physics.

[133]  J A Rowlands,et al.  A solid-state amorphous selenium avalanche technology for low photon flux imaging applications. , 2010, Medical physics.

[134]  M. Schieber,et al.  ADVANCES IN PHYSICAL VAPOR DEPOSITED POLYCRYSTALLINE-HgI2 X-RAY IMAGING DETECTORS , 2003 .

[135]  A. Peacock,et al.  Analytic model for the spatial and spectral resolution of pixellated semiconducting detectors of high-energy photons , 2005 .

[136]  Laurie L Fajardo,et al.  Digital mammography: a review of technical development and clinical applications. , 2003, Clinical breast cancer.

[137]  F. Ren,et al.  Science of dry etching of III-V materials , 1994 .

[138]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[139]  J A Rowlands,et al.  Design and feasibility of active matrix flat panel detector using avalanche amorphous selenium for protein crystallography. , 2008, Medical physics.

[140]  R. A. Ford,et al.  Analysis of lead oxide (PbO) layers for direct conversion X-ray detection , 2004, IEEE Transactions on Nuclear Science.

[141]  Yael Nemirovsky,et al.  STATISTICAL MODELING OF CHARGE COLLECTION IN SEMICONDUCTOR GAMMA-RAY SPECTROMETERS , 1999 .

[142]  R. Brenner,et al.  Calculation of the modulation transfer function for the X-ray imaging detector DIXI using Monte Carlo simulation data , 2001 .

[143]  H. Nilsson,et al.  Spectral response of pixellated semiconductor X-ray detectors , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[144]  Karim S. Karim,et al.  High dynamic range pixel architecture for advanced diagnostic medical x-ray imaging applications , 2006 .

[145]  Satoshi Tokuda,et al.  Preparation and characterization of polycrystalline CdZnTe films for large-area, high-sensitivity X-ray detectors , 2004 .

[146]  R. Steadman,et al.  Status of Direct Conversion Detectors for Medical Imaging With X-Rays , 2009, IEEE Transactions on Nuclear Science.

[147]  M. Z. Kabir,et al.  Direct conversion X-ray sensors: sensitivity, DQE and MTF , 2003 .

[148]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection. , 1998, Medical physics.

[149]  J A Rowlands,et al.  Flat-panel digital radiology with amorphous selenium and active-matrix readout. , 1997, Radiographics : a review publication of the Radiological Society of North America, Inc.

[150]  J. Rowlands,et al.  Investigation of a direct conversion flat panel imager for portal imaging. , 2001, Medical physics.

[151]  I. Aguiar,et al.  Comparison Of Mercuric Bromide And Lead Bromide Layers as Photoconductors For Direct X-ray Imaging Applications , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[152]  M. Z. Kabir,et al.  Time and exposure dependent x-ray sensitivity in multilayer amorphous selenium detectors , 2008 .

[153]  L. Fornaro,et al.  Low dark current (00l) mercuric iodide thick films for X-ray direct and digital imagers , 2004, IEEE Transactions on Nuclear Science.

[154]  M. Rabbani,et al.  Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[155]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency. , 1997, Medical physics.

[156]  J A Rowlands,et al.  Development of high quantum efficiency flat panel detectors for portal imaging: intrinsic spatial resolution. , 2002, Medical physics.

[157]  Martin J Yaffe,et al.  Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency. , 2002, Medical physics.