Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
暂无分享,去创建一个
Habib Mani | John A. Rowlands | Luc Laperrière | Karim S. Karim | Alla Reznik | George Belev | Olivier Tousignant | Joel B. Frey | Jonathan E. Greenspan | Giovanni DeCrescenzo | Safa Kasap | Oleksandr Bubon | S. Kasap | O. Tousignant | K. Karim | J. Rowlands | G. Belev | J. Greenspan | A. Reznik | L. Laperrière | J. Frey | O. Bubon | H. Mani | G. DeCrescenzo
[1] Susumu Adachi,et al. Improvement of temporal response and output uniformity of polycrystalline CdZnTe films for high-sensitivity x-ray imaging , 2003, SPIE Medical Imaging.
[2] Arokia Nathan,et al. Amorphous silicon active pixel sensor readout circuit for digital imaging , 2003 .
[3] A. Peacock,et al. The effect of carrier diffusion on the characteristics of semiconductor imaging arrays , 2004 .
[4] J A Rowlands,et al. X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain. , 2002, Medical physics.
[5] F. Thibault,et al. Digital detectors for mammography: the technical challenges , 2004, European Radiology.
[6] Larry Partain,et al. Dark current and DQE improvements of mercuric iodide medical imagers , 2007, SPIE Medical Imaging.
[7] K. Taketoshi,et al. An avalanche-mode amorphous Selenium photoconductive layer for use as a camera tube target , 1987, IEEE Electron Device Letters.
[8] Roberto S. Murphy-Arteaga,et al. n型非晶質SiGe:H/p型結晶質Siヘテロ接合ダイオードの伝導機構に及ぼすa‐SiGe:H厚の影響 , 2005 .
[9] M. Z. Kabir,et al. Effect of repeated x-ray exposure on the resolution of amorphous selenium based x-ray imagers. , 2010, Medical physics.
[10] Arokia Nathan,et al. Amorphous silicon technology for large area digital X-ray and optical imaging , 2002, Microelectron. Reliab..
[11] Isaac N. Bankman,et al. Handbook of medical imaging , 2000 .
[12] Rena Lee,et al. Investigation of PbI2 Film Fabricated by a New Sedimentation Method as an X-ray Conversion Material , 2010 .
[13] Martin J Yaffe,et al. A CdZnTe slot-scanned detector for digital mammography. , 2002, Medical physics.
[14] Kenkichi Tanioka,et al. Ultrahigh-sensitivity New Super-HARP camera , 1996 .
[15] Habib Mani,et al. Dark current in multilayer amorphous selenium x-ray imaging detectors , 2008 .
[16] Ezio Caroli,et al. Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications , 2009, Sensors.
[17] C. Mun,et al. Effect of Annealing on the X-ray Detection Properties of Nano-sized Polycrystalline Lead Oxide Films , 2008 .
[18] Olivier Tousignant,et al. An a-Si Active Pixel Sensor (APS) Array for Medical X-ray Imaging , 2010, IEEE Transactions on Electron Devices.
[19] S. Kasap,et al. Relaxation of the electrical properties of vacuum-deposited a-Se1−xAsx photoconductive films: Charge-carrier lifetimes and drift mobilities , 2010 .
[20] Haim Hermon,et al. High-flux x-ray response of composite mercuric iodide detectors , 1999, Optics & Photonics.
[21] Safa Kasap,et al. DQE of photoconductive x-ray image detectors: application to a-Se , 2002 .
[23] John A. Rowlands,et al. Digital radiology using self-scanned readout of amorphous selenium: design considerations for mammography , 1995, Medical Imaging.
[24] JengPing Lu,et al. New materials and processes for flat panel X-ray detectors , 2003 .
[25] Satoshi Yamada,et al. Large-area deposition of a polycrystalline CdZnTe film and its applicability to x-ray panel detectors with superior sensitivity , 2002, SPIE Medical Imaging.
[27] Safa Kasap,et al. Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes , 2009 .
[28] J. Yorkston. Recent developments in digital radiography detectors , 2007 .
[29] Kanai S. Shah,et al. Electronic transport in polycrystalline Pbl2 films , 1999 .
[30] T. Mertelmeier,et al. Modulation transfer function of a selenium-based digital mammography system , 2004, IEEE Transactions on Nuclear Science.
[31] Bo Zhao,et al. Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system. , 2008, Medical physics.
[32] Safa Kasap,et al. Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors , 2004 .
[33] Safa Kasap,et al. X-ray sensitivity of photoconductors: application to stabilized a-Se , 2000 .
[34] Paul J. Sellin,et al. Recent advances in compound semiconductor radiation detectors , 2003 .
[35] Kenkichi Tanioka,et al. X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise. , 2007, Medical physics.
[36] W. Zhao,et al. Digital radiology using active matrix readout: amplified pixel detector array for fluoroscopy. , 1999, Medical physics.
[37] J A Rowlands,et al. X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.
[38] M. Z. Kabir,et al. Recent advances in X-ray photoconductors for direct conversion X-ray image detectors , 2006 .
[39] S. Kasap,et al. Density of localized electronic states in a-Se from electron time-of-flight photocurrent measurements , 2005 .
[40] John A. Rowlands,et al. Flat Panel Detectors for Digital Radiography , 2000 .
[41] I. Blevis,et al. Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. , 1997, Medical physics.
[42] A. Nathan,et al. Readout circuit in active pixel sensors in amorphous silicon technology , 2001, IEEE Electron Device Letters.
[43] Arokia Nathan,et al. Noise performance of a current-mediated amplified pixel for large-area medical imaging , 2004 .
[44] W. Kalender,et al. Flat-detector computed tomography (FD-CT) , 2007, European Radiology.
[45] Qihua Zhao,et al. Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography. , 2007, Medical physics.
[46] Martin Hoheisel,et al. Review of medical imaging with emphasis on X-ray detectors , 2006 .
[47] Zhong He,et al. Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectors , 2001 .
[48] J A Rowlands,et al. Digital radiology using active matrix readout of amorphous selenium: geometrical and effective fill factors. , 1998, Medical physics.
[49] J A Rowlands,et al. X-ray imaging using amorphous selenium: inherent spatial resolution. , 1995, Medical physics.
[50] J. Lai,et al. High dynamic range active pixel sensor arrays for digital x-ray imaging using a-Si:H , 2006 .
[51] Qihua Zhao,et al. Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2. , 2008, Physics in medicine and biology.
[52] F. Taghibakhsh,et al. Two-Transistor Active Pixel Sensor Readout Circuits in Amorphous Silicon Technology for High-Resolution Digital Imaging Applications , 2008, IEEE Transactions on Electron Devices.
[53] Richard L. Van Metter,et al. Handbook of Medical Imaging , 2009 .
[54] Qihua Zhao,et al. Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors. , 2009, Medical physics.
[55] S. Kasap,et al. An interrupted field time‐of‐flight (IFTOF) technique in transient photoconductivity measurements , 1990 .
[56] Anthony J. Peacock,et al. Resolution degradation of semiconductor detectors due to carrier trapping , 2005 .
[57] Wei Zhao,et al. Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium. , 2005, Medical physics.
[58] Qihua Zhao,et al. An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays. , 2009, Medical physics.
[59] O. Rubel,et al. Generalized lucky-drift model for impact ionization in semiconductors with disorder , 2011, Journal of physics. Condensed matter : an Institute of Physics journal.
[60] I A Cunningham,et al. Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors. , 2006, Medical physics.
[61] K.S. Karim,et al. Digital X-Ray Imaging Using Avalanche a-Se Photoconductor , 2010, IEEE Sensors Journal.
[62] Rebecca Fahrig,et al. Design, Performance, and Applications of a Hybrid X-Ray/MR System for Interventional Guidance , 2008, Proceedings of the IEEE.
[63] R. Shaw,et al. The Equivalent Quantum Efficiency of the Photographic Process , 1963 .
[64] S. Kasap. Charge transport in selenium based amorphous xerographic photoreceptors , 1983 .
[65] S. Kasap,et al. Lucky-drift model for impact ionization in amorphous semiconductors , 2009 .
[66] J. Plešek,et al. Nonlinear elastic behavior in compression of thermally sprayed materials , 2002 .
[67] A. Shor,et al. CdTe and CdZnTe Room-Temperature X-Ray and Gamma Ray Detectors and Imaging Systems , 1997 .
[68] J A Rowlands,et al. X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology. , 1995, Medical physics.
[69] M. Z. Kabir,et al. The effects of large signals on charge collection in radiation detectors : Application to amorphous selenium detectors , 2006 .
[70] J. Rowlands,et al. Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI. , 2008, Medical physics.
[71] M. Z. Kabir. Effects of charge carrier trapping on polycrystalline PbO x-ray imaging detectors , 2008 .
[72] I. Cunningham,et al. On the Development of Digital Radiography Detectors : A Review , 2008 .
[73] Arokia Nathan,et al. Low-noise pixel architecture for advanced diagnostic medical x-ray imaging applications , 2006, SPIE Medical Imaging.
[74] S. Kasap. Dark decay of electrostatic surface potential on dielectrics via bulk space-charge buildup , 1989 .
[75] M. Braiman,et al. Novel mercuric iodide polycrystalline nuclear particles counters , 1996 .
[76] M. Z. Kabir,et al. Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trapping , 2003 .
[77] Safa Kasap,et al. Direct-conversion flat-panel X-ray image detectors , 2002 .
[78] Thomas J. Meyer,et al. Effect of 1/f noise in integrating sensors and detectors , 2011, IET Circuits Devices Syst..
[79] J. Anthony Seibert,et al. Flat-panel detectors: how much better are they? , 2006, Pediatric Radiology.
[80] L. Antonuk,et al. Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. , 2010, Medical physics.
[83] J A Rowlands,et al. Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. , 2004, Medical physics.
[84] John A Rowlands,et al. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system. , 2008, Medical physics.
[85] Denny L. Y. Lee,et al. New digital detector for projection radiography , 1995, Medical Imaging.
[86] Ho Kyung Kim. Analytical model for incomplete signal generation in semiconductor detectors , 2006 .
[87] Safa Kasap,et al. Reduction of the dark current in stabilized a-Se based X-ray detectors , 2006 .
[88] Sunetra K. Mendis,et al. CMOS active pixel image sensor , 1994 .
[89] Kanai S. Shah,et al. X-ray imaging with PbI2-based A-Si:H flat panel detectors , 2001 .
[90] Maximilian F Reiser,et al. Advances in digital radiography: physical principles and system overview. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.
[91] K. Arlauskas,et al. Features of Hot Carriers in Amorphous Selenium , 1983 .
[92] Safa Kasap,et al. Amorphous selenium as an X-ray photoconductor , 2004 .
[93] Ulrich Neitzel,et al. Status and prospects of digital detector technology for CR and DR. , 2005, Radiation protection dosimetry.
[94] Safa Kasap,et al. Direct-conversion flat-panel X-ray image sensors for digital radiography , 2002, Proceedings of the IEEE.
[95] Qihua Zhao,et al. Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. , 2010, Medical physics.
[96] J. Krenn,et al. Improvement of light extraction from high-power flip-chip light-emitting diodes by femtosecond laser direct structuring of the sapphire backside surface , 2008 .
[97] Kenneth C. Young,et al. Breast Cancer: Advances in X-ray mammography , 2010 .
[99] Paul J. Sellin,et al. Thick film compound semiconductors for X-ray imaging applications , 2006 .
[100] Martin Spahn,et al. Flat detectors and their clinical applications , 2005, European Radiology.
[101] S. Kasap,et al. Charge transport and electron-hole-pair creation energy in stabilized a-Se x-ray photoconductors , 1999 .
[102] Wei Zhao,et al. Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector. , 2003, Medical physics.
[103] S. Kasap,et al. Effect of aging on glass transformation measurements by temperature modulated DSC , 2002 .
[104] S. Kröger,et al. Bismuth tri-iodide polycrystalline films for X-ray direct and digital imagers , 2009 .
[105] H. B. Barber,et al. Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.
[106] J. Iwanczyk,et al. HgI/sub 2/ polycrystalline films for digital X-ray imagers , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).
[107] S. Bloom,et al. Electron-Hole-Pair Creation Energies in Semiconductors , 1975 .
[108] Kenkichi Tanioka,et al. Avalanche multiplication phenomenon in amorphous semiconductors : Amorphous selenium versus hydrogenated amorphous silicon , 2007 .
[109] M. Z. Kabir,et al. Sensitivity of stabilized a-Se based X-ray photoconductors , 2006 .
[110] Habib Mani,et al. Spatial and temporal image characteristics of a real-time large area a-Se x-ray detector , 2005, SPIE Medical Imaging.
[111] Safa Kasap,et al. Charge collection and absorption-limited sensitivity of x-ray photoconductors: Applications to a-Se and HgI2 , 2002 .
[113] Denny L. Y. Lee,et al. Discussion on resolution and dynamic range of Se-TFT direct digital radiographic detector , 1996, Medical Imaging.
[114] S. Kasap,et al. Electronic and thermal properties of magnesium‐doped a‐Se films , 2009 .
[115] Richard L. Weisfield,et al. Two Dimensional Amorphous Silicon Image Sensor Arrays , 1995 .
[116] Olivier Bonnaud,et al. Low-frequency noise in low temperature unhydrogenated polysilicon thin film transistors , 2000 .
[117] K. Arlauskas,et al. Impact Ionization and Mobilities of Charge Carriers at High Electric Fields in Amorphous Selenium , 1980, May 16.
[118] Kenkichi Tanioka,et al. Lucky drift impact ionization in amorphous semiconductors , 2004 .
[119] Robert A. Street,et al. Thick films of X-ray polycrystalline mercuric iodide detectors , 2001 .
[120] Kanai S. Shah,et al. Comparison of PbI2 and HgI2 for direct detection active matrix x-ray image sensors , 2002 .
[121] J A Rowlands,et al. X-ray imaging with amorphous selenium: pulse height measurements of avalanche gain fluctuations. , 2006, Medical physics.
[122] Kenkichi Tanioka,et al. X-ray imaging using avalanche multiplication in amorphous selenium: investigation of intrinsic avalanche noise. , 2007, Medical physics.
[123] Daniela Dragoman,et al. Optical analogue of a type II semiconductor heterostructure , 2000 .
[124] Sung-Ho Cho,et al. Quantitative evaluation of mercuric iodide thick film for x-ray imaging device , 2006, SPIE Medical Imaging.
[125] M. Schieber,et al. Near single-crystal electrical properties of polycrystalline HgI/sub 2/ produced by physical vapor deposition , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.
[126] Safa Kasap,et al. Amorphous Semiconductors Usher in Digital X‐Ray Imaging , 1997 .
[127] Claude A. Klein,et al. Bandgap Dependence and Related Features of Radiation Ionization Energies in Semiconductors , 1968 .
[128] J A Rowlands,et al. Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors. , 2001, Medical physics.
[129] Matthias Simon,et al. PbO as direct conversion x-ray detector material , 2004, SPIE Medical Imaging.
[130] Wei Zhao,et al. Amorphous selenium flat panel detectors for medical applications , 2005 .
[131] T. Peter Brody. The birth and early childhood of active matrix — A personal memoir , 1996 .
[132] J A Rowlands,et al. The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors. , 2007, Medical physics.
[133] J A Rowlands,et al. A solid-state amorphous selenium avalanche technology for low photon flux imaging applications. , 2010, Medical physics.
[134] M. Schieber,et al. ADVANCES IN PHYSICAL VAPOR DEPOSITED POLYCRYSTALLINE-HgI2 X-RAY IMAGING DETECTORS , 2003 .
[135] A. Peacock,et al. Analytic model for the spatial and spectral resolution of pixellated semiconducting detectors of high-energy photons , 2005 .
[136] Laurie L Fajardo,et al. Digital mammography: a review of technical development and clinical applications. , 2003, Clinical breast cancer.
[137] F. Ren,et al. Science of dry etching of III-V materials , 1994 .
[138] H. S. Wolff,et al. iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.
[139] J A Rowlands,et al. Design and feasibility of active matrix flat panel detector using avalanche amorphous selenium for protein crystallography. , 2008, Medical physics.
[140] R. A. Ford,et al. Analysis of lead oxide (PbO) layers for direct conversion X-ray detection , 2004, IEEE Transactions on Nuclear Science.
[141] Yael Nemirovsky,et al. STATISTICAL MODELING OF CHARGE COLLECTION IN SEMICONDUCTOR GAMMA-RAY SPECTROMETERS , 1999 .
[142] R. Brenner,et al. Calculation of the modulation transfer function for the X-ray imaging detector DIXI using Monte Carlo simulation data , 2001 .
[143] H. Nilsson,et al. Spectral response of pixellated semiconductor X-ray detectors , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.
[144] Karim S. Karim,et al. High dynamic range pixel architecture for advanced diagnostic medical x-ray imaging applications , 2006 .
[145] Satoshi Tokuda,et al. Preparation and characterization of polycrystalline CdZnTe films for large-area, high-sensitivity X-ray detectors , 2004 .
[146] R. Steadman,et al. Status of Direct Conversion Detectors for Medical Imaging With X-Rays , 2009, IEEE Transactions on Nuclear Science.
[147] M. Z. Kabir,et al. Direct conversion X-ray sensors: sensitivity, DQE and MTF , 2003 .
[148] J A Rowlands,et al. Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection. , 1998, Medical physics.
[149] J A Rowlands,et al. Flat-panel digital radiology with amorphous selenium and active-matrix readout. , 1997, Radiographics : a review publication of the Radiological Society of North America, Inc.
[150] J. Rowlands,et al. Investigation of a direct conversion flat panel imager for portal imaging. , 2001, Medical physics.
[151] I. Aguiar,et al. Comparison Of Mercuric Bromide And Lead Bromide Layers as Photoconductors For Direct X-ray Imaging Applications , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.
[152] M. Z. Kabir,et al. Time and exposure dependent x-ray sensitivity in multilayer amorphous selenium detectors , 2008 .
[153] L. Fornaro,et al. Low dark current (00l) mercuric iodide thick films for X-ray direct and digital imagers , 2004, IEEE Transactions on Nuclear Science.
[154] M. Rabbani,et al. Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms. , 1987, Journal of the Optical Society of America. A, Optics and image science.
[155] J A Rowlands,et al. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency. , 1997, Medical physics.
[156] J A Rowlands,et al. Development of high quantum efficiency flat panel detectors for portal imaging: intrinsic spatial resolution. , 2002, Medical physics.
[157] Martin J Yaffe,et al. Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency. , 2002, Medical physics.