Implant Surface Topographies Analyzed Using Fractal Dimension

Purpose:The aim of this study was to assess the fractal dimension (Df) of disks with 3 different surface topographies. Materials and Methods:Thirty disk-shaped samples (10 × 2 mm) with 3 different surface topographies (Dental Tech, Misinto, Italy) were analyzed by scanning electron microscopy: group A, machined surface; group B, titanium plasma-spray surface; group C, acid-etched and sandblasted surface (Blasted Wrinkled Surface). Results:The amplitude roughness parameter (Sa) of the machined surfaces was 0.6 &mgr;m, while the developed surface area ratio (Sdr) was 14%; for the titanium plasma-spray surfaces, the values were, respectively, 5.3 &mgr;m and 97%, and for the Blasted Wrinkled Surfaces, 1.5 &mgr;m and 63%. Images at 1.000, 20.000, and 50.000 magnifications were processed for quantitative analysis of Df using the box-counting method. At 1.000×, Df for group A, B, and C was 1.86, 1.80, and 1.81, respectively; at 20.000×, Df for group A, B, and C was 1.85, 1.71, 1.58, respectively; and at 50.000×, Df was 1.83, 1.61, and 1.51 for A, B, and C groups. Statistically significant differences were found for Df values. Conclusions:Df provides not only an index of roughness size values but also a measure of roughness spatial organization; therefore, it could be a promising method to differentiate between rough surfaces capable of supporting osseointegration.

[1]  Caterina Guiot,et al.  Fractal parameters and vascular networks: facts & artifacts , 2008, Theoretical Biology and Medical Modelling.

[2]  Gabriel Landini,et al.  Quantification of the global and local complexity of the epithelial-connective tissue interface of normal, dysplastic, and neoplastic oral mucosae using digital imaging. , 2003, Pathology, research and practice.

[3]  V. Velanovich Fractal analysis of mammographic lesions: a feasibility study quantifying the difference between benign and malignant masses. , 1996, The American journal of the medical sciences.

[4]  Sophia Xiang Updike,et al.  Fractal analysis of dental radiographs to detect periodontitis-induced trabecular changes. , 2008, Journal of periodontal research.

[5]  E. Patsouris,et al.  Nuclear fractal dimension as a prognostic factor in oral squamous cell carcinoma. , 2008, Oral oncology.

[6]  Maxence Bigerelle,et al.  Qualitative and quantitative study of human osteoblast adhesion on materials with various surface roughnesses. , 2000, Journal of biomedical materials research.

[7]  Paulo G Coelho,et al.  Classification of osseointegrated implant surfaces: materials, chemistry and topography. , 2010, Trends in biotechnology.

[8]  Reinhilde Jacobs,et al.  Bone quality assessment based on cone beam computed tomography imaging. , 2009, Clinical oral implants research.

[9]  Maxence Bigerelle,et al.  Topography effects of pure titanium substrates on human osteoblast long-term adhesion. , 2005, Acta biomaterialia.

[10]  J R Jakobsen,et al.  Fractal dimension in radiographic analysis of alveolar process bone. , 1996, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[11]  Kinam Park,et al.  Fractal Analysis of Pharmaceutical Particles by Atomic Force Microscopy , 1998, Pharmaceutical Research.

[12]  Pranab Dey,et al.  Fractal dimension in endometrial carcinoma. , 2004, Analytical and quantitative cytology and histology.

[13]  Werner Lutzenberger,et al.  Fractal dimensions of short EEG time series in humans , 1997, Neuroscience Letters.

[14]  Takashi Sato,et al.  Image analysis of irregularity of cluster shape in cytological diagnosis of breast tumors: Cluster analysis with 2D‐fractal dimension , 2005, Diagnostic cytopathology.

[15]  B. Boyan,et al.  Regulation of angiogenesis during osseointegration by titanium surface microstructure and energy. , 2010, Biomaterials.

[16]  Martin A Mainster,et al.  The fractal properties of retinal vessels: Embryological and clinical implications , 1990, Eye.

[17]  Erkan Aydar,et al.  Quantitative analysis on volcanic ash surfaces: application of extended depth-of-field (focus) algorithm for light and scanning electron microscopy and 3D reconstruction. , 2008, Micron.

[18]  S. Cross,et al.  Quantitation of the renal arterial tree by fractal analysis , 1993, The Journal of pathology.

[19]  F. Yaşar,et al.  Fractal dimension and lacunarity analysis of dental radiographs. , 2005, Dento maxillo facial radiology.

[20]  R Balon,et al.  Fractal dimension of heart rate time series: an effective measure of autonomic function. , 1993, Journal of applied physiology.

[21]  R. Cortvrindt,et al.  Confocal microscopy: principles and applications to the field of reproductive biology. , 2001, Folia histochemica et cytobiologica.

[22]  C. Kittas,et al.  Fractal dimension as a prognostic factor for laryngeal carcinoma. , 2005, Anticancer research.

[23]  E. Gelsema,et al.  Estimation of fractal dimension in radiographs. , 1996, Medical physics.

[24]  I. Ohlídal,et al.  Influence of the atomic force microscope tip on the multifractal analysis of rough surfaces. , 2004, Ultramicroscopy.

[25]  S S Cross,et al.  FRACTALS IN PATHOLOGY , 1997, The Journal of pathology.

[26]  G. Henebry,et al.  Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images. , 2001, Medical engineering & physics.

[27]  P. D. de Oliveira,et al.  In vitro osteogenesis on a microstructured titanium surface with additional submicron-scale topography. , 2007, Clinical oral implants research.

[28]  Nebojsa T. Milosevic,et al.  Fractal and nonfractal analysis of cell images: comparison and application to neuronal dendritic arborization , 2002, Biological Cybernetics.

[29]  Peter S Ungar,et al.  Quantification of dental microwear by tandem scanning confocal microscopy and scale-sensitive fractal analyses. , 2006, Scanning.

[30]  E. Sabo,et al.  Microscopic analysis and significance of vascular architectural complexity in renal cell carcinoma. , 2001, Clinical cancer research : an official journal of the American Association for Cancer Research.

[31]  Bruce J. West,et al.  The fractal lung: Universal and species-related scaling patterns , 1990, Experientia.

[32]  E Oczeretko,et al.  Fractal geometric analysis of lung cancer angiogenic patterns. , 2001, Folia histochemica et cytobiologica.

[33]  Konradin Metze,et al.  Shannon's entropy and fractal dimension provide an objective account of bone tissue organization during calvarial bone regeneration , 2008, Microscopy research and technique.

[34]  Naomichi Ogihara,et al.  Mechanism of skull suture maintenance and interdigitation , 2009, Journal of anatomy.

[35]  Soon-Chul Choi,et al.  Fractal analysis of mandibular bony healing after orthognathic surgery. , 2002, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[36]  Luigi Pannarale,et al.  Fractal and Fourier analysis of the hepatic sinusoidal network in normal and cirrhotic rat liver , 2005, Journal of anatomy.

[37]  R. Wilding,et al.  The use of fractal analysis to reveal remodelling in human alveolar bone following the placement of dental implants. , 1995, Archives of oral biology.

[38]  P. Waliszewski,et al.  Distribution of gland‐like structures in human gallbladder adenocarcinomas possesses fractal dimension , 1999, Journal of surgical oncology.

[39]  G. Latini,et al.  Abnormal oral vascular network pattern geometry: a new clinical sign of down syndrome. , 2006, The Journal of pediatrics.

[40]  Yongping Chen,et al.  Role of surface roughness characterized by fractal geometry on laminar flow in microchannels. , 2009, Physical review. E, Statistical, nonlinear, and soft matter physics.

[41]  T. Albrektsson,et al.  On implant surfaces: a review of current knowledge and opinions. , 2010, The International journal of oral & maxillofacial implants.

[42]  Franz Halberg,et al.  Circadian rhythmic fractal scaling of heart rate variability in health and coronary artery disease , 1997, Clinical cardiology.

[43]  J. Bassingthwaighte,et al.  Fractal Nature of Regional Myocardial Blood Flow Heterogeneity , 1989, Circulation research.

[44]  N Pradhan,et al.  Use of running fractal dimension for the analysis of changing patterns in electroencephalograms. , 1993, Computers in biology and medicine.