Quantification of plasmid DNA reference materials for Shiga toxin-producing Escherichia coli based on UV, HR-ICP-MS and digital PCR

BackgroundThe accuracy and metrology traceability of DNA quantification is becoming a critical theme in many fields, including diagnosis, forensic analysis, microorganism detection etc. Thus the research of DNA reference materials (RMs) and consistency of DNA quantification methods has attracted considerable research interest.ResultsIn this work, we developed 3 plasmid candidate RMs, containing 3 target genes of Escherichia coli O157:H7 (E. coli O157:H7) and other Shiga toxin-producing Escherichia coli (STEC): stx1, stx2, and fliC (h7) respectively. Comprehensive investigation of the plasmid RMs was performed for their sequence, purity, homogeneity and stability, and then the concentration was quantified by three different methods: ultraviolet spectrophotometer (UV), high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) and digital PCR. As a routinely applied method for DNA analysis, UV was utilized for the quantification (OD260) and purity analysis for the plasmids. HR-ICP-MS quantified the plasmid DNA through analysing the phosphorus in DNA molecules. Digital PCR distributed the DNA samples onto a microarray chip containing thousands of reaction chambers, and quantified the DNA copy numbers by analysing the number of positive signals without any calibration curves needed.ConclusionsBased on the high purification of the DNA reference materials and the optimization of dPCR analysis, we successfully achieved good consistency between UV, HR-ICP-MS and dPCR, with relative deviations lower than 10 %. We then performed the co-quantification of 3 DNA RMs with three different methods together, and the uncertainties of their concentration were evaluated. Finally, the certified values and expanded uncertainties for 3 DNA RMs (pFliC, pStx1 and pStx2) were (1.60 ± 0.10) × 1010 copies/μL, (1.53 ± 0.10) × 1010 copies/μL and (1.70 ± 0.11) × 1010 copies/μL respectively.Graphical abstractWe developed 3 plasmid candidate RMs, containing 3 target genes of Escherichia coli O157:H7 (E. coli O157:H7) and other Shiga toxin-producing Escherichia coli (STEC): stx1, stx2, and fliC (h7) respectively, and the quantification of three different methods (UV, dPCR, ICP) was studied.

[1]  Jim F Huggett,et al.  Comparative study of sensitivity, linearity, and resistance to inhibition of digital and nondigital polymerase chain reaction and loop mediated isothermal amplification assays for quantification of human cytomegalovirus. , 2014, Analytical chemistry.

[2]  L. Garrelly,et al.  The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR , 2013, Journal of applied microbiology.

[3]  Kerry R Emslie,et al.  Comparison of methods for accurate quantification of DNA mass concentration with traceability to the international system of units. , 2010, Analytical chemistry.

[4]  Blaza Toman,et al.  Standard reference material 2366 for measurement of human cytomegalovirus DNA. , 2013, The Journal of molecular diagnostics : JMD.

[5]  Peter M Vallone,et al.  Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard , 2009, Analytical and bioanalytical chemistry.

[6]  C. Ateba,et al.  Detection of Escherichia coli O157:H7 virulence genes in isolates from beef, pork, water, human and animal species in the northwest province, South Africa: public health implications. , 2011, Research in microbiology.

[7]  J. Sambrook,et al.  Molecular Cloning: A Laboratory Manual , 2001 .

[8]  S. Vaslin-Reimann,et al.  Method development for genomic Legionella pneumophila DNA quantification by inductively coupled plasma mass spectrometry. , 2013, Analytical biochemistry.

[9]  H. Emons,et al.  Evaluation of plasmid and genomic DNA calibrants used for the quantification of genetically modified organisms , 2012, Analytical and Bioanalytical Chemistry.

[10]  Christopher M. Hindson,et al.  Absolute quantification by droplet digital PCR versus analog real-time PCR , 2013, Nature Methods.

[11]  David L. Swerdlow,et al.  Epidemiology of Escherichia coli O157:H7 Outbreaks, United States, 1982–2002 , 2005, Emerging infectious diseases.

[12]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[13]  A. C. Arisi,et al.  Development of plasmid DNA reference material for the quantification of genetically modified common bean embrapa 5.1. , 2013, Journal of agricultural and food chemistry.

[14]  K. Chong,et al.  Impedimetric graphene-based biosensor for the detection of Escherichia coli DNA , 2014 .

[15]  Lianhua Dong,et al.  Digital polymerase chain reaction measured pUC19 marker as calibrant for HPLC measurement of DNA quantity. , 2013, Analytical chemistry.

[16]  A. Woolford,et al.  Quantitation of oligonucleotides by phosphodiesterase digestion followed by isotope dilution mass spectrometry: proof of concept. , 2002, Analytical chemistry.

[17]  T. Pan,et al.  Quantification Bias Caused by Plasmid DNA Conformation in Quantitative Real-Time PCR Assay , 2011, PloS one.

[18]  G. Turk,et al.  Potential primary measurement tool for the quantification of DNA. , 2009, Analytical chemistry.

[19]  J. Paton,et al.  Detection and characterization of Shiga toxigenic Escherichia coli by using multiplex PCR assays for stx1, stx2, eaeA, enterohemorrhagic E. coli hlyA, rfbO111, and rfbO157. , 1998, Journal of clinical microbiology.

[20]  C. DebRoy,et al.  Detection of Escherichia coli O157:H7 in Food Using Real-Time Multiplex PCR Assays Targeting the stx1, stx2, wzyO157, and the fliCh7 or eae Genes , 2010 .

[21]  Kerry R Emslie,et al.  Effect of sustained elevated temperature prior to amplification on template copy number estimation using digital polymerase chain reaction. , 2011, The Analyst.

[22]  X. Nou,et al.  Seasonal prevalence of Shiga toxin-producing Escherichia coli, including O157:H7 and non-O157 serotypes, and Salmonella in commercial beef processing plants. , 2003, Journal of food protection.

[23]  Nick L Hjelm,et al.  Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing. , 2013, The Journal of molecular diagnostics : JMD.

[24]  J. Wells,et al.  Non-O157 Shiga toxin-producing Escherichia coli infections in the United States, 1983-2002. , 2005, The Journal of infectious diseases.

[25]  M. Holden,et al.  Traceable phosphorus measurements by ICP-OES and HPLC for the quantitation of DNA. , 2007, Analytical chemistry.

[26]  Kate R. Griffiths,et al.  Quantitative polymerase chain reaction: a framework for improving the quality of results and estimating uncertainty of measurement , 2011 .