Polymeric membrane phosphate sensitive electrode based on binuclear organotin compound

Abstract Binuclear organotin compounds incorporated in solvent polymeric membranes can act as carriers for phosphate ions. A poly(vinyl chloride) membrane containing bis(tribenzyltin) oxide, o-nitrophenyl octyl ether as plasticizer showed Nernstian response for hydrogen phosphate in the 5 × 10−6–10−1 mol 1−1 activity range with a slope of −30.1 mV dec−1 in solutions of pH 7.20 ± 0.02. The electrode displayed the following selectivity sequence: HPO42− > I− > Br− > NO3− > Cl− > Ac− > SO42−, which was not in accordance with the Hofmeister series. Also included is the comparison of potentiometric response characteristics between the binuclear and mononuclear organotin compounds. An enhanced response towards HPO42− for the binuclear compound based electrode was observed, showing that binuclear organometallic compounds may become a promising class of carriers for anions.

[1]  K. Sisido,et al.  Direct Synthesis of Organotin Compounds. I. Di- and Tribenzyltin Chlorides , 1961 .

[2]  L. Bachas,et al.  Anion-selective electrodes based on a hydrophobic vitamin B12 derivative , 1989 .

[3]  M. Arnold,et al.  Selectivity of membrane electrodes based on derivatives of dibenzyltin dichloride. , 1991, Analytical chemistry.

[4]  M. Newcomb,et al.  Macrocycles Containing Tin. The Preparation of Macrobicyclic Lewis Acidic Hosts Containing Two Tin Atoms and 119-Sn NMR Studies of Their Chloride and Bromide Binding Properties in Solution , 1989 .

[5]  M A Arnold,et al.  Phosphate-selective polymer membrane electrode. , 1988, Analytical chemistry.

[6]  J. Koryta Theory and applications of ion-selective electrodes part 4 , 1982 .

[7]  E. Pretsch,et al.  Tin organic compounds as neutral carriers for anion selective electrodes , 1984 .

[8]  R. Yu,et al.  Metalloporphyrin Derivatives as Neutral Carriers for PVC Membrane Electrodes , 1994 .

[9]  M. Meyerhoff,et al.  Influence of porphyrin structure on anion selectivities of manganese(III) porphyrin based membrane electrodes. , 1988, Analytical Chemistry.

[10]  G. J. Moody,et al.  A calcium-sensitive electrode based on a liquid ion exchanger in a poly(vinyl chloride) matrix , 1970 .

[11]  R. Yu,et al.  Nitrite-sensitive liquid membrane electrodes based on metalloporphyrin derivatives , 1995 .

[12]  T. Shono,et al.  Properties of cis- and trans-bis(crown ether)s for complexation and extraction of alkali metal picrates. , 1980, Talanta.

[13]  C M Carey,et al.  Cyclic polyamine ionophore for use in a dibasic phosphate-selective electrode. , 1994, Analytical chemistry.

[14]  G. J. Moody,et al.  PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments , 1974 .

[15]  U. Schaller,et al.  Ionic additives for ion-selective electrodes based on electrically charged carriers , 1994 .

[16]  M. Arnold,et al.  Progress In Phosphate-Selective Electrode Development , 1989 .

[17]  M. Newcomb,et al.  Macrocycles containing tin. Solid complexes of anions encrypted in macrobicyclic Lewis acidic hosts , 1989 .

[18]  R. Yu,et al.  Neutral carrier membrane electrode based on binuclear metalloporphyrin , 1995 .

[19]  M. Meyerhoff,et al.  Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity. , 1994, Talanta.

[20]  Y. Chai,et al.  Schiff base complexes of cobalt(II) as neutral carriers for highly selective iodide electrodes , 1993 .