Comparison of CAIPIRINHA-VIBE, Radial-VIBE, and conventional VIBE sequences for dynamic contrast-enhanced (DCE) MRI: A validation study using a DCE-MRI phantom.

OBJECTIVE To validate radial acquisition of volumetric interpolated breath hold examination (Radial-VIBE) and the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA-VIBE) sequences for dynamic contrast-enhanced MRI (DCE-MRI) by comparing them to conventional VIBE sequence using a phantom. METHODS On a DCE-MRI phantom containing various concentrations of NiCl2 solutions, six minutes of dynamic series and T1 mapping with variable flip angle methods were acquired using conventional VIBE, Radial-VIBE, and CAIPIRINHA-VIBE sequences on 3.0-T scanners. Signal stability and signal linearity were tested for dynamic series and the precision of R1 values were tested for T1 mapping series. The scans were repeatedly performed at two weeks and three months to test repeatability/reproducibility, assessed by within-subject coefficient of variation (WSCV). RESULTS Signal stability over six minutes was excellent in all three sequences. Regarding the signal linearity, CAIPIRINHA-VIBE demonstrated the highest linear correlation (r=0.963), followed by conventional VIBE (r=0.959) and Radial-VIBE (r=0.953). Regarding the R1 precision, CAIPIRINHA-VIBE (r=0.985) was the most accurate, followed by conventional VIBE (r=0.861) and Radial-VIBE (r=0.442). CAIPIRINHA-VIBE showed excellent repeatability/reproducibility (WSCV, 1.79-6.71%) compared with Radial-VIBE (WSCV, 2.04-67.2%) and conventional VIBE (WSCV, 3.4-31.9%). CONCLUSION In terms of signal stability, signal linearity, R1 precision, and repeatability/reproducibility, CAIPIRINHA-VIBE demonstrated outstanding performance for DCE-MRI compared with Radial-VIBE and conventional VIBE.

[1]  Wei Lin,et al.  Respiratory motion‐compensated radial dynamic contrast‐enhanced (DCE)‐MRI of chest and abdominal lesions , 2008, Magnetic resonance in medicine.

[2]  Tong San Koh,et al.  Perfusion magnetic resonance imaging of the liver. , 2010, World journal of gastroenterology.

[3]  Berthold Kiefer,et al.  Usefulness of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration in Gadoxetic Acid–Enhanced Liver Magnetic Resonance Imaging to Clarify the Hepatic Arterial Phase , 2014, Investigative radiology.

[4]  Bong Soo Kim,et al.  New Imaging Strategies Using a Motion-Resistant Liver Sequence in Uncooperative Patients , 2014, BioMed research international.

[5]  A. Jackson,et al.  Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies , 2012, Nature Reviews Clinical Oncology.

[6]  Simon Bauer,et al.  Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC) , 2013, European Radiology.

[7]  Danny C. Kim,et al.  Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence: A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration , 2011, Investigative radiology.

[8]  H. Rusinek,et al.  Dynamic contrast-enhanced MR imaging of the liver: current status and future directions. , 2009, Magnetic resonance imaging clinics of North America.

[9]  Lawrence Dougherty,et al.  Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution , 2004, Magnetic resonance in medicine.

[10]  Berthold Kiefer,et al.  Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)‐volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid‐enhanced liver MR imaging , 2013, Journal of magnetic resonance imaging : JMRI.