Design of anthropomorphic flow phantoms based on rapid prototyping of compliant vessel geometries.

Anatomically realistic flow phantoms are essential experimental tools for vascular ultrasound. Here we describe how these flow phantoms can be efficiently developed via a rapid prototyping (RP) framework that involves direct fabrication of compliant vessel geometries. In this framework, anthropomorphic vessel models were drafted in computer-aided design software, and they were fabricated using stereolithography (one type of RP). To produce elastic vessels, a compliant photopolymer was used for stereolithography. We fabricated a series of compliant, diseased carotid bifurcation models with eccentric stenosis (50%) and plaque ulceration (types I and III), and they were used to form thin-walled flow phantoms by coupling the vessels to an agar-based tissue-mimicking material. These phantoms were found to yield Doppler spectrograms with significant spectral broadening and color flow images with mosaic patterns, as typical of disturbed flow under stenosed and ulcerated disease conditions. Also, their wall distension behavior was found to be similar to that observed in vivo, and this corresponded with the vessel wall's average elastic modulus (391 kPa), which was within the nominal range for human arteries. The vessel material's acoustic properties were found to be sub-optimal: the estimated average acoustic speed was 1801 m/s, and the attenuation coefficient was 1.58 dB/(mm·MHz(n)) with a power-law coefficient of 0.97. Such an acoustic mismatch nevertheless did not notably affect our Doppler spectrograms and color flow image results. These findings suggest that phantoms produced from our design framework have the potential to serve as ultrasound-compatible test beds that can simulate complex flow dynamics similar to those observed in real vasculature.

[1]  D. Holdsworth,et al.  Characterization of common carotid artery blood-flow waveforms in normal human subjects , 1999, Physiological measurement.

[2]  K V Ramnarine,et al.  Construction and geometric stability of physiological flow rate wall-less stenosis phantoms. , 2001, Ultrasound in medicine & biology.

[3]  Hristo N Nikolov,et al.  An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation. , 2002, Ultrasound in medicine & biology.

[4]  R Eugene Zierler,et al.  Carotid artery stenosis: gray-scale and Doppler US diagnosis--Society of Radiologists in Ultrasound Consensus Conference. , 2003, Radiology.

[5]  N. Raine-Fenning,et al.  Determining the relationship between three‐dimensional power Doppler data and true blood flow characteristics: an in‐vitro flow phantom experiment , 2008, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[6]  Frederik L. Giesel,et al.  3D printing based on imaging data: review of medical applications , 2010, International Journal of Computer Assisted Radiology and Surgery.

[7]  David W. Holdsworth,et al.  Clinical Doppler ultrasound for the assessment of plaque ulceration in the stenosed carotid bifurcation by detection of distal turbulence intensity: a matched model study , 2009, European Radiology.

[8]  W. McDicken,et al.  Doppler Ultrasound: Physics, Instrumentation and Signal Processing , 2000 .

[9]  S Meagher,et al.  Design and characterisation of a wall motion phantom. , 2006, Ultrasound in medicine & biology.

[10]  Peter M. Rothwell,et al.  Histological Correlates of Carotid Plaque Surface Morphology on Lumen Contrast Imaging , 2004, Circulation.

[11]  B. Sonesson,et al.  Diameter and compliance in the human common carotid artery--variations with age and sex. , 1995, Ultrasound in medicine & biology.

[12]  M E Bastin,et al.  Anatomical flow phantoms of the nonplanar carotid bifurcation, part I: computer-aided design and fabrication. , 2007, Ultrasound in medicine & biology.

[13]  R. Niessner,et al.  Acoustical properties of selected tissue phantom materials for ultrasound imaging , 2007, Physics in medicine and biology.

[14]  J D'hooge,et al.  A dual-chamber, thick-walled cardiac phantom for use in cardiac motion and deformation imaging by ultrasound. , 2010, Ultrasound in medicine & biology.

[15]  K V Ramnarine,et al.  Validation of a new blood-mimicking fluid for use in Doppler flow test objects. , 1998, Ultrasound in medicine & biology.

[16]  R S Cobbold,et al.  Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow. , 2001, Ultrasound in medicine & biology.

[17]  Peter M. Rothwell,et al.  Site of Carotid Plaque Ulceration in Relation to Direction of Blood Flow: An Angiographic and Pathological Study , 2003, Cerebrovascular Diseases.

[18]  Ellen T Roche,et al.  Generating an Ex Vivo Vascular Model , 2005, ASAIO journal.

[19]  J. Browne,et al.  Development of a range of anatomically realistic renal artery flow phantoms. , 2010, Ultrasound in medicine & biology.

[20]  Hristo N Nikolov,et al.  Doppler ultrasound compatible plastic material for use in rigid flow models. , 2008, Ultrasound in medicine & biology.

[21]  Ravi Managuli,et al.  Three-Dimensional Ultrasound: From Acquisition to Visualization and From Algorithms to Systems , 2009, IEEE Reviews in Biomedical Engineering.

[22]  David W Holdsworth,et al.  Flow patterns in carotid bifurcation models using pulsed Doppler ultrasound: effect of concentric vs. eccentric stenosis on turbulence and recirculation. , 2010, Ultrasound in medicine & biology.

[23]  Hristo N Nikolov,et al.  A thin-walled carotid vessel phantom for Doppler ultrasound flow studies. , 2004, Ultrasound in medicine & biology.

[24]  Andrea Scorza,et al.  Calibration procedure for performance evaluation of clinical Pulsed Doppler Systems , 2012 .

[25]  P. Olofsson,et al.  Flow index evaluation of 3-D volume flow images: an in vivo and in vitro study. , 2006, Ultrasound in medicine & biology.

[26]  Andrés Díaz Lantada,et al.  Rapid prototyping for biomedical engineering: current capabilities and challenges. , 2012, Annual review of biomedical engineering.

[27]  Jacinta E Browne,et al.  Development of a vessel-mimicking material for use in anatomically realistic Doppler flow phantoms. , 2011, Ultrasound in medicine & biology.

[28]  Jacinta E Browne,et al.  Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners. , 2004, Ultrasound in medicine & biology.

[29]  R. F. Smith,et al.  Anthropomorphic carotid bifurcation phantom for MRI applications , 1999, Journal of magnetic resonance imaging : JMRI.

[30]  Peter R Hoskins,et al.  Physical properties of tissues relevant to arterial ultrasound imaging and blood velocity measurement. , 2007, Ultrasound in medicine & biology.

[31]  R. F. Smith,et al.  Geometric characterization of stenosed human carotid arteries. , 1996, Academic radiology.

[32]  F. Foster,et al.  Tissue equivalent vessel phantoms for intravascular ultrasound. , 1997, Ultrasound in medicine & biology.

[33]  Marcello Pellicciari,et al.  Hyperelastic Modeling of Rubber-Like Photopolymers for Additive Manufacturing Processes , 2011 .

[34]  Richard S C Cobbold,et al.  Human factors as a source of error in peak Doppler velocity measurement. , 2005, Journal of vascular surgery.

[35]  S Meagher,et al.  Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: experimental validation with Doppler ultrasound. , 2007, Ultrasound in medicine & biology.

[36]  H. Cardinal,et al.  A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow. , 2001, Ultrasound in medicine & biology.

[37]  P. Fish,et al.  A simulation study of sample volume sensitivity for oblique pulsed finite beam insonation of Doppler ultrasound flow phantom cylindrical vessels , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[38]  Effects of beam steering in pulsed-wave ultrasound velocity estimation. , 2005, Ultrasound in medicine & biology.

[39]  K V Ramnarine,et al.  Evaluation of the effect of machine settings on quantitative three‐dimensional power Doppler angiography: an in‐vitro flow phantom experiment , 2008, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[40]  Peter R Hoskins,et al.  Simulation and validation of arterial ultrasound imaging and blood flow. , 2008, Ultrasound in medicine & biology.

[41]  Scott E Kasner,et al.  Carotid Artery Diameter in Men and Women and the Relation to Body and Neck Size , 2006, Stroke.