A new on-line monitoring method of transformer winding axial displacement based on measurement of scattering parameters and decision tree

In this paper the scattering parameter of a simplified model of transformer has been measured in different axial displacement of the winding using a Network Analyzer. Two indices have been suggested to detect the axial displacement. The measurement results show the effectiveness of these indices. A new method of the detection of the axial displacement extent based on decision tree (DT) has been proposed, too. It has been shown that this method has a good accuracy to determine the displacement of the winding and its extent.

[1]  K. Feser,et al.  Procedures for detecting winding displacements in power transformers by the transfer function method , 2004, IEEE Transactions on Power Delivery.

[2]  Chao-Tung Yang,et al.  Decision tree construction for data mining on grid computing , 2004, IEEE International Conference on e-Technology, e-Commerce and e-Service, 2004. EEE '04. 2004.

[3]  Wei-Yin Loh,et al.  Classification and regression trees , 2011, WIREs Data Mining Knowl. Discov..

[4]  D. K. Xu,et al.  On-line monitoring of winding deformation of power transformer , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[5]  Isabelle Guyon,et al.  An Introduction to Variable and Feature Selection , 2003, J. Mach. Learn. Res..

[6]  A. S. Morched,et al.  Analysis of internal winding stresses in EHV generator step-up transformer failures , 1996 .

[7]  T. Leibfried,et al.  Off-line- and on-line-monitoring of power transformers using the transfer function method , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[8]  J. Borak Feature selection and land cover classification of a MODIS-like data set for a semiarid environment , 1999 .

[9]  M.D. Judd,et al.  Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretation , 2005, IEEE Electrical Insulation Magazine.

[10]  Gevork B. Gharehpetian,et al.  Determination of axial displacement extent based on transformer winding transfer function estimation using vector-fitting method , 2008 .

[11]  N. D. Hatziargyriou,et al.  On-Line Preventive Dynamic Security of Isolated Power Systems Using Decision Trees , 2002, IEEE Power Engineering Review.

[12]  Haibin Zhu,et al.  An Adaptive Fuzzy kNN Text Classifier Based on Gini Index Weight , 2006, 11th IEEE Symposium on Computers and Communications (ISCC'06).

[13]  T. Leibfried,et al.  Monitoring of power transformers using the transfer function method , 1999 .

[14]  D. Pozar Microwave Engineering , 1990 .

[15]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[16]  Caixin Sun,et al.  Study on the recognition of transformer winding deformation by using wavelet transform in the LVI method , 2002, Proceedings. International Conference on Power System Technology.

[17]  M.D. Judd,et al.  Partial discharge monitoring for power transformer using UHF sensors. Part 2: field experience , 2005, IEEE Electrical Insulation Magazine.

[18]  J. Ross Quinlan,et al.  C4.5: Programs for Machine Learning , 1992 .

[19]  R. Wimmer,et al.  Calculation of the transfer function of a power transformer with online measuring data , 2004 .