A positron emission tomography/computed tomography (PET/CT) acquisition protocol for CT radiation dose optimization

BackgroundIn current combined positron emission tomography/computed tomography (PET/CT) systems, high-quality CT images not only increase diagnostic value by providing anatomic delineation of hyper- and hypometabolic tissues, but also shorten the acquisition time for attenuation correction compared with standard PET imaging. However, this technique potentially introduces more radiation burden to patients as a result of the higher radiation exposure from CT. MethodsIn this study, the radiation doses delivered from typical germanium-based and CT-based transmission scans were measured and compared using an anthropomorphic Rando Alderson phantom with insertions of thermoluminescent dosimeters. Image geometric distortion and quantified uptake values in PET images with different manipulating CT acquisition protocols for attenuation correction were also evaluated. ResultsIt was found that radiation doses during germanium-based transmission scans were almost negligible, while doses from CT-based transmission scans were significantly higher. Using a lower radiation dose, the CT acquisition protocol did not significantly affect attenuation correction and anatomic delineation in PET. ConclusionsThis study revealed the relation between image information and dose. The current PET/CT imaging acquisition protocol was improved by decreasing the radiation risks without sacrificing the diagnostic values

[1]  Masatoshi Itoh,et al.  Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-d- glucose using whole-body positron emission tomography and magnetic resonance imaging , 1998, European Journal of Nuclear Medicine.

[2]  A. Jurik,et al.  Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni , 1996, Skeletal Radiology.

[3]  Norbert Avril,et al.  Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images , 1997, European Journal of Nuclear Medicine.

[4]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Valerie Treyer,et al.  CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[6]  C. Meltzer,et al.  Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner , 2000, Clinical nuclear medicine.

[7]  Thomas F Hany,et al.  PET diagnostic accuracy: improvement with in-line PET-CT system: initial results. , 2002, Radiology.

[8]  D Visvikis,et al.  Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PET. , 2001, European journal of nuclear medicine.

[9]  M. Defrise,et al.  Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction , 1999, European Journal of Nuclear Medicine.

[10]  A. Buck,et al.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[11]  R. Wahl,et al.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  D. Visvikis,et al.  CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  J. Debatin,et al.  Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. , 2003, Radiology.

[14]  N. Mullani,et al.  A segmented attenuation correction for PET. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  D W. Townsend,et al.  Combined PET/CT Imaging in Oncology. Impact on Patient Management. , 2000, Clinical positron imaging : official journal of the Institute for Clinical P.E.T.

[16]  Thomas Beyer,et al.  Acquisition protocol considerations for combined PET/CT imaging. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  Arnaud Peltier,et al.  Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimeters , 1998, European Journal of Nuclear Medicine.

[18]  Mathias Cohnen,et al.  Effective doses in standard protocols for multi-slice CT scanning , 2003, European Radiology.