Power Management of Islanded Self-Excited Induction Generator Reinforced by Energy Storage Systems

Self-Excited Induction Generators (SEIGs), e.g., Small-Scale Embedded wind generation, are increasingly used in electricity distribution networks. The operational stability of stand-alone SEIG is constrained by the local load conditions: stability can be achieved by maintaining the load’s active and reactive power at optimal values. Changes in power demand are dependent on customers’ requirements, and any deviation from the pre-calculated optimum setting will affect a machine’s operating voltage and frequency. This paper presents an investigation of the operation of the SEIG in islanding mode of operation under different load conditions, with the aid of batteries as an energy storage source. In this research a current-controlled voltage-source converter is proposed to regulate the power exchange between a direct current (DC) energy storage source and an alternating current (AC) grid, the converter’s controller is driven by any variation between machine capability and load demand. In order to prolong the system stability when the battery reaches its operation constraints, it is recommended that an ancillary generator and a dummy local load be embedded in the system. The results show the robustness and operability of the proposed system in the islanding mode of the SEIG under different load conditions.

[1]  Vivek Agarwal,et al.  A new variable speed constant voltage controller for self-excited induction generator , 2001 .

[2]  James F. Manwell,et al.  A power electronics based power shedding control for wind/diesel systems , 1992 .

[3]  Akbar Maleki,et al.  Optimal sizing of a PV/wind/diesel system with battery storage for electrification to an off-grid remote region: A case study of Rafsanjan, Iran , 2014 .

[4]  Jayaraman Ramachandran,et al.  Dynamic behaviour of single-phase induction generators during disconnection and reconnection to the grid , 2008 .

[5]  José L. Bernal-Agustín,et al.  Multi-objective optimization minimizing cost and life cycle emissions of stand-alone PV–wind–diesel systems with batteries storage , 2011 .

[6]  Amit Kumar,et al.  IMPLEMENTATION OF SELF EXCITED INDUCTION GENERATOR (SEIG) WITH IGBT BASED ELECTRONIC LOAD CONTROLLER (ELC) IN WIND ENERGY SYSTEMS , 2013 .

[7]  M. Ebadian,et al.  Analytical investigation of the effect of wind farm equipped with SCIG on voltage stability , 2012, 2012 Second Iranian Conference on Renewable Energy and Distributed Generation.

[8]  J. Arrillaga,et al.  Static power conversion from self-excited induction generators , 1978 .

[9]  G. Bhuvaneswari,et al.  Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads , 2010 .

[10]  R. Grino,et al.  Voltage and Frequency Control for a Self-Excited Induction Generator Using a Three-Phase Four-Wire Electronic Converter , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[11]  M Miloje Kostic EQUIVALENT CIRCUIT IMPROVEMENT METHOD FOR INDUCTION MOTOR EFFICIENCY , 2012 .

[12]  T.A. Lipo,et al.  Controlled shunt capacitor self-excited induction generator , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[13]  Danny Sutanto,et al.  Steady-state and transient analysis of self-excited induction generators , 1989 .

[14]  Anurag K. Srivastava,et al.  Impact of Distributed Generations With Energy Storage Devices on the Electric Grid , 2012, IEEE Systems Journal.

[15]  R. Grino,et al.  Standalone Self-Excited Induction Generator with a Three-Phase Four-Wire Active Filter and Energy Storage System , 2007, 2007 IEEE International Symposium on Industrial Electronics.

[16]  J. B. Ekanayake,et al.  Induction generators for small hydro schemes , 2002 .

[17]  S.Sasikumar Analysis of Self Excited Induction Generators , 2013 .

[18]  R. K. Saket,et al.  Reliability evaluation of SEIG rotor core magnetization with minimum capacitive excitation for unregulated renewable energy applications in remote areas , 2014 .

[19]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[20]  S. Abdelkader Voltage stability assessment for systems with large wind power generation , 2009, 2009 44th International Universities Power Engineering Conference (UPEC).

[21]  S. A. Deraz,et al.  A new control strategy for a stand-alone self-excited induction generator driven by a variable speed wind turbine , 2013 .

[22]  Bhim Singh,et al.  Design-based performance evaluation of two-winding capacitor self- excited single-phase induction generator , 2003 .

[23]  David C. Yu,et al.  Optimal sizing of hybrid PV/diesel/battery in ship power system ☆ , 2015 .

[24]  Javier Reneses,et al.  Cost–benefit analysis of battery storage in medium-voltage distribution networks , 2016 .

[25]  Mahendra Pal Sharma,et al.  A review on configurations, control and sizing methodologies of hybrid energy systems , 2014 .

[26]  R. Bonert,et al.  Self-excited induction generator with excellent voltage and frequency control , 1998 .

[27]  Bhim Singh,et al.  Selection of capacitors for the self regulated short shunt self excited induction generator , 1995 .

[28]  Junji Tamura,et al.  Analysis of an isolated self-excited induction generator , 2000 .

[29]  Colin D. Schauder,et al.  Current Control of Voltage-Source Inverters for Fast Four-Quadrant Drive Performance , 1982, IEEE Transactions on Industry Applications.

[30]  M. B. Brennen,et al.  Vector analysis and control of advanced static VAr compensators , 1991 .

[31]  Mohamed Emad Farrag,et al.  Analysis of the Dynamic Performance of Self-Excited Induction Generators Employed in Renewable Energy Generation , 2014 .

[32]  E. Bim,et al.  Voltage Compensation of an Induction Generator with Long-Shunt Connection , 1989, IEEE Power Engineering Review.

[33]  F. M. Porter,et al.  Capacitive excitation for induction generators , 1935, Electrical Engineering.